AXITEC AC-335MH/120V — CEC Solar Module Specifications

Manufacturer: AXITEC Registry: CEC Verified Engineering Specification

AXITEC AC-335MH/120V is a 335.0 W STC (313.3 W PTC) Mono-c-Si solar module ranking #13,844 of 21,677 CEC listings (below all-CEC median; higher than 34.7% of peers). It delivers 20.18% efficiency, 40.44 V Voc at 25 C, and 44.22 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
335.0 W
PTC Wattage
313.3 W
Voc @ 25C
40.44 V
Efficiency
20.18%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does AXITEC AC-335MH/120V Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for AXITEC AC-335MH/120V (Mono-c-Si) residential solar systems.

Homeowners evaluating AXITEC AC-335MH/120V need 18 panels for 6 kW or 24 panels (429 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (429 sq ft). Under NEC 690.7(A), beta_Voc (-0.267%/C) pushes open-circuit voltage to 44.22 V at 14 F and 45.3 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does AXITEC AC-335MH/120V Fall Across Listed CEC Models?

Comparison of AXITEC AC-335MH/120V (335.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where AXITEC AC-335MH/120V (335.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAXITEC AC-335MH/12: 335.0 W

What Dataset Percentiles Define AXITEC AC-335MH/120V?

Relative ranking of AXITEC AC-335MH/120V across nameplate watts, 93.5% PTC thermal ratio, and module aperture efficiency. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

AXITEC AC-335MH/120V Engineering BenchmarksPercentile comparison of AXITEC AC-335MH/120V wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage335.0 WPTC/STC Retention93.5%Module Efficiency20.18%

What Do the Dataset Ranks Show for AXITEC AC-335MH/120V?

Summary of AXITEC AC-335MH/120V output rank, 8 kW array size (24 panels), efficiency rating, and 600 V string limit.

Rank #13,844 / 21,677

335.0 W STC · Higher Than 34.7%

335.0 W STC (-50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,844

20.18% Aperture Efficiency

Power density 201.8 W/m2 (0.27 percentage points above 19.91% CEC median). PTC/STC ratio: 93.5% (rank #7,159).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.22 V at -10 C (574.9 V string) and 45.3 V at -20 C (13 max).

8 kW Reference Array

24 Panels = 8,040 W STC

Occupies 39.8 m2 (429 sq ft) producing 7,519 W PTC; NEC 690.8 OCPD floor is 16.54 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.44 * (1 + (-0.267/100) * (-10 - 25)) = 44.22 V | OCPD = 1.56 * 10.6 = 16.54 A

Inputs from CEC Modules.csv for AXITEC AC-335MH/120V: Voc=40.44 V, beta_Voc=-0.267%/C, Isc=10.6 A, STC=335.0 W, Area=1.66 m2.

Result: 13 panels max on 600 V (574.9 V); 24 panels for 8 kW (429 sq ft).

What Are the Published CEC Specifications for AXITEC AC-335MH/120V?

Complete CEC test sheet for AXITEC AC-335MH/120V including Isc (10.6 A), Voc (40.44 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for AXITEC AC-335MH/120V.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 335.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 313.3 W (93.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 40.44 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.6 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 33.11 V / 10.11 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.267 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.18% (1.66 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many AXITEC AC-335MH/120V Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using AXITEC AC-335MH/120V.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 18 6.03 kW 322 sq ft $1,509 $2,552
8 kW Class 24 8.04 kW 429 sq ft $2,012 $3,403
10 kW Class 30 10.05 kW 536 sq ft $2,515 $4,253

Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?

Related AXITEC power steps and black/silver trims consolidated into this AXITEC AC-335MH/120V series guide. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the AXITEC AC-335MH/120V wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
AXITEC AC-325MH/120V 325.0 W 303.7 W 40.1 V 32.71 V 19.58%
AXITEC AC-330MH/120V 330.0 W 308.5 W 40.27 V 32.91 V 19.88%
AXITEC AC-335MH/120V 335.0 W 313.3 W 40.44 V 33.11 V 20.18%
AXITEC AC-340MH/120V 340.0 W 318.1 W 40.62 V 33.31 V 20.48%

How Many AXITEC AC-335MH/120V Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for AXITEC AC-335MH/120V (40.44 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=40.44V and beta_Voc=-0.267%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.3 V 13 panels 588.9 V 22 panels
-10 C (14 F) 44.22 V 13 panels 574.9 V 22 panels
0 C (32 F) 43.14 V 13 panels 560.8 V 23 panels
25 C (77 F STC) 40.44 V 14 panels 566.2 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-335MH/120V?

Four comparable CEC modules such as Aptos Solar Technology LLC DNA-120-MF23-335W {Blk} (335.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Aptos Solar Technology LLC DNA-120-MF23-335W {Blk}
Aptos Solar Technology LLC
335.0 W Tie (0 W) 40.44 V 19.85% 90.8%
Aptos Solar Technology LLC DNA-120-MF23-335W {Wht}
Aptos Solar Technology LLC
335.0 W Tie (0 W) 40.44 V 20.55% 93.6%
Dehui Solar Power (Vietnam) CoLtd DH-M860W 335W
Dehui Solar Power (Vietnam) CoLtd
335.0 W Tie (0 W) 40.7 V 21.07% 92.6%
Auxin Solar AXNG1M335B
Auxin Solar
335.0 W Tie (0 W) 40.75 V 20.43% 93.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for AXITEC AC-335MH/120V?

Evaluate AXITEC AC-335MH/120V (335.0 W STC, 40.44 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-335MH/120V reaches 45.3 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 24 panels for an 8 kW build require 429 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (429 sq ft).
  • 2026 tax credit baseline: cash residential installs of AXITEC AC-335MH/120V carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

AXITEC AC-335MH/120V 8 kW Residential Fit

Needs 24 modules (429 sq ft) with a 20 A string OCPD, offsetting ~$2,012/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Aptos Solar Technology LLC DNA-120-MF23-335W {Blk}.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 313.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for AXITEC AC-335MH/120V by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.

Why is AXITEC AC-335MH/120V PTC wattage (313.3 W) lower than STC (335.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 313.3 W PTC (93.5% retention) across AXITEC AC-335MH/120V's 1.66 m2 aperture.

Who should skip AXITEC AC-335MH/120V on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 24 AXITEC AC-335MH/120V panels (429 sq ft) leave unusable roof gaps vs. Aptos Solar Technology LLC DNA-120-MF23-335W {Blk}.

What is the 1,000 V commercial string limit for AXITEC AC-335MH/120V?

On 1,000 V commercial inverters at -10 C (44.22 V cold Voc), AXITEC AC-335MH/120V fits up to 22 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting AXITEC AC-335MH/120V.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.