Skip to main content
WireAndSun
Calculators
CEC PV Module

DualSun SAS DualSun 340M-120-00 — CEC Solar Module Specifications

Manufacturer: DualSun SAS Registry: CEC Verified Engineering Specification

DualSun SAS DualSun 340M-120-00 is a 340.0 W STC (316.8 W PTC) Mono-c-Si solar module ranking #13,575 of 21,677 CEC listings (below all-CEC median; higher than 36.1% of peers). It delivers 18.78% efficiency, 40.1 V Voc at 25 C, and 43.88 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
340.0 W
PTC Wattage
316.8 W
Voc @ 25C
40.1 V
Efficiency
18.78%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does DualSun SAS DualSun 340M-120-00 Compare Against Peer CEC Listings?

Solar engineering breakdown for DualSun SAS DualSun 340M-120-00: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from DualSun SAS and peers, DualSun SAS DualSun 340M-120-00 stands 70.0 W below the 410.0 W Mono-c-Si median and strong 93.2% PTC-to-STC heat retention (#8,924 of 21,677). Sizing 6 kW (18 panels) to 10 kW (30 panels) yields $1,532-$2,553/yr in baseline US bill offset. Mid-range 40.1 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.

Where Does DualSun SAS DualSun 340M-120-00 Fall Across Listed CEC Models?

Distribution marker showing DualSun SAS DualSun 340M-120-00 (340.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where DualSun SAS DualSun 340M-120-00 (340.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCDualSun SAS DualSu: 340.0 W

What Dataset Percentiles Define DualSun SAS DualSun 340M-120-00?

Dataset percentiles tracking DualSun SAS DualSun 340M-120-00 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

DualSun SAS DualSun 340M-120-00 Engineering BenchmarksPercentile comparison of DualSun SAS DualSun 340M-120-00 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage340.0 WPTC/STC Retention93.2%Module Efficiency18.78%

What Do the Dataset Ranks Show for DualSun SAS DualSun 340M-120-00?

Benchmark highlights for DualSun SAS DualSun 340M-120-00 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #13,575 / 21,677

340.0 W STC · Higher Than 36.1%

340.0 W STC (-45.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #13,876

18.78% Aperture Efficiency

Power density 187.8 W/m2 (1.13 percentage points below 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.88 V at -10 C (570.4 V string) and 44.95 V at -20 C (13 max).

8 kW Reference Array

24 Panels = 8,160 W STC

Occupies 43.4 m2 (468 sq ft) producing 7,603 W PTC; NEC 690.8 OCPD floor is 16.91 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.1 * (1 + (-0.269/100) * (-10 - 25)) = 43.88 V | OCPD = 1.56 * 10.84 = 16.91 A

Inputs from CEC Modules.csv for DualSun SAS DualSun 340M-120-00: Voc=40.1 V, beta_Voc=-0.269%/C, Isc=10.84 A, STC=340.0 W, Area=1.81 m2.

Result: 13 panels max on 600 V (570.4 V); 24 panels for 8 kW (468 sq ft).

What Are the Published CEC Specifications for DualSun SAS DualSun 340M-120-00?

Official CEC datasheet figures for DualSun SAS DualSun 340M-120-00 (Mono-c-Si) used in utility interconnection and permit reviews. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Official California Energy Commission (NREL SAM) test parameters for DualSun SAS DualSun 340M-120-00.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 340.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 316.8 W (93.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 40.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.84 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.9 V / 10.34 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.269 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.78% (1.81 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many DualSun SAS DualSun 340M-120-00 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many DualSun SAS DualSun 340M-120-00 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 18 6.12 kW 351 sq ft $1,532 $2,590
8 kW Class 24 8.16 kW 468 sq ft $2,042 $3,454
10 kW Class 30 10.2 kW 584 sq ft $2,553 $4,317

Which Sibling Wattage & Trim Variants Belong to This DualSun SAS Series?

Consolidated DualSun SAS wattage variants sharing the DualSun SAS DualSun 340M-120-00 mechanical and cell layout. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the DualSun SAS DualSun 340M-120-00 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
DualSun SAS DualSun 335M-120-00 335.0 W 312.0 W 39.9 V 32.7 V 18.51%
DualSun SAS DualSun 340M-120-00 340.0 W 316.8 W 40.1 V 32.9 V 18.78%
DualSun SAS DualSun 345M-120-00 345.0 W 321.5 W 40.3 V 33.1 V 19.06%

How Many DualSun SAS DualSun 340M-120-00 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on DualSun SAS DualSun 340M-120-00 (43.88 V at 14 F).

Computed from Voc=40.1V and beta_Voc=-0.269%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.95 V 13 panels 584.4 V 22 panels
-10 C (14 F) 43.88 V 13 panels 570.4 V 22 panels
0 C (32 F) 42.8 V 14 panels 599.2 V 23 panels
25 C (77 F STC) 40.1 V 14 panels 561.4 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to DualSun SAS DualSun 340M-120-00?

Competing CEC solar panels closest to DualSun SAS DualSun 340M-120-00 in nameplate wattage and Voc, starting with Caterpillar Inc PVC345MP03HA.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Caterpillar Inc PVC345MP03HA
Caterpillar Inc
345.0 W +5.0 W 40.2 V 19.49% 93.3%
ELITE Solar ET-M660BH345BB
ELITE Solar
345.0 W +5.0 W 39.9 V 19.17% 93.5%
CSI Solar Co Ltd CS3L-345MS
CSI Solar Co Ltd
345.0 W +5.0 W 39.8 V 19.27% 92.9%
Aptos Solar Technology LLC DNA-120-MF23-335W {Blk}
Aptos Solar Technology LLC
335.0 W -5.0 W 40.44 V 19.85% 90.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for DualSun SAS DualSun 340M-120-00?

Evaluate DualSun SAS DualSun 340M-120-00 (340.0 W STC, 40.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), DualSun SAS DualSun 340M-120-00 reaches 44.95 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 24 panels for an 8 kW build require 468 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (468 sq ft).
  • 2026 tax credit baseline: cash residential installs of DualSun SAS DualSun 340M-120-00 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

DualSun SAS DualSun 340M-120-00 8 kW Residential Fit

Needs 24 modules (468 sq ft) with a 20 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Caterpillar Inc PVC345MP03HA.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 316.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for DualSun SAS DualSun 340M-120-00 by DualSun SAS grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for DualSun SAS DualSun 340M-120-00?

Multiplying DualSun SAS DualSun 340M-120-00's 10.84 A short-circuit current by 1.56 equals 16.91 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can DualSun SAS DualSun 340M-120-00 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 43.88 V cold Voc at 14 F and handles 10.84 A Isc; string inverters cap DualSun SAS DualSun 340M-120-00 at 13 panels on 600 V.

Is DualSun SAS DualSun 340M-120-00 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of DualSun SAS DualSun 340M-120-00 rely on utility bill offset (~$2,042/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.