Caterpillar Inc PVC380MP03 is a 380.0 W STC (355.2 W PTC) Mono-c-Si solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 20.21% efficiency, 49.03 V Voc at 25 C, and 53.54 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 380.0 W
- PTC Wattage
- 355.2 W
- Voc @ 25C
- 49.03 V
- Efficiency
- 20.21%
How Does Caterpillar Inc PVC380MP03 Compare Against Peer CEC Listings?
Solar engineering breakdown for Caterpillar Inc PVC380MP03: PTC thermal retention, roof footprint, and cold Voc string bounds. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
Measured at 380.0 W STC and 355.2 W PTC, Caterpillar Inc PVC380MP03 sits -5.0 W vs all-CEC median (below all-CEC median; higher than 47.6% of peers) among 21,677 listed modules. Power density reaches 202.1 W/m2 (0.30 percentage points above 19.91% CEC median). Higher 49.03 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer Crossroads Solar Crossroads Solar 380 rates 380.0 W.
Where Does Caterpillar Inc PVC380MP03 Fall Across Listed CEC Models?
Distribution marker showing Caterpillar Inc PVC380MP03 (380.0 W) relative to the 385.0 W all-CEC solar panel median. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
What Dataset Percentiles Define Caterpillar Inc PVC380MP03?
Dataset percentiles tracking Caterpillar Inc PVC380MP03 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
What Do the Dataset Ranks Show for Caterpillar Inc PVC380MP03?
Benchmark highlights for Caterpillar Inc PVC380MP03 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
380.0 W STC · Higher Than 47.6%
380.0 W STC (-5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.21% Aperture Efficiency
Power density 202.1 W/m2 (0.30 percentage points above 19.91% CEC median). PTC/STC ratio: 93.5% (rank #7,159).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.54 V at -10 C (588.9 V string) and 54.83 V at -20 C (10 max).
22 Panels = 8,360 W STC
Occupies 41.4 m2 (445 sq ft) producing 7,814 W PTC; NEC 690.8 OCPD floor is 15.6 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.03 * (1 + (-0.263/100) * (-10 - 25)) = 53.54 V | OCPD = 1.56 * 10.0 = 15.6 A
Inputs from CEC Modules.csv for Caterpillar Inc PVC380MP03: Voc=49.03 V, beta_Voc=-0.263%/C, Isc=10.0 A, STC=380.0 W, Area=1.88 m2.
Result: 11 panels max on 600 V (588.9 V); 22 panels for 8 kW (445 sq ft).
What Are the Published CEC Specifications for Caterpillar Inc PVC380MP03?
Official CEC datasheet figures for Caterpillar Inc PVC380MP03 (Mono-c-Si) used in utility interconnection and permit reviews. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 380.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 355.2 W (93.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.03 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.0 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.41 V / 9.4 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.263 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.21% (1.88 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Caterpillar Inc PVC380MP03 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Caterpillar Inc PVC380MP03 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.08 kW | 324 sq ft | $1,522 | $2,573 |
| 8 kW Class | 22 | 8.36 kW | 445 sq ft | $2,092 | $3,538 |
| 10 kW Class | 27 | 10.26 kW | 546 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This Caterpillar Inc Series?
Consolidated Caterpillar Inc wattage variants sharing the Caterpillar Inc PVC380MP03 mechanical and cell layout. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Caterpillar Inc PVC375MP03 | 375.0 W | 350.4 W | 48.71 V | 40.08 V | 19.95% |
| Caterpillar Inc PVC380MP03 | 380.0 W | 355.2 W | 49.03 V | 40.41 V | 20.21% |
How Many Caterpillar Inc PVC380MP03 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Caterpillar Inc PVC380MP03 (53.54 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.83 V | 10 panels | 548.3 V | 18 panels |
| -10 C (14 F) | 53.54 V | 11 panels | 588.9 V | 18 panels |
| 0 C (32 F) | 52.25 V | 11 panels | 574.8 V | 19 panels |
| 25 C (77 F STC) | 49.03 V | 12 panels | 588.4 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Caterpillar Inc PVC380MP03?
Competing CEC solar panels closest to Caterpillar Inc PVC380MP03 in nameplate wattage and Voc, starting with Crossroads Solar Crossroads Solar 380.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Crossroads Solar Crossroads Solar 380 Crossroads Solar |
380.0 W | Tie (0 W) | 49.0 V | 18.63% | 92.2% |
| Bluesun Solar Energy Tech CoLtd BSM380M-72 Bluesun Solar Energy Tech CoLtd |
380.0 W | Tie (0 W) | 48.67 V | 19.59% | 92.0% |
| Auxin Solar AXN6M612T380 Auxin Solar |
380.0 W | Tie (0 W) | 47.94 V | 19.58% | 91.9% |
| CertainTeed CT380M10-02 CertainTeed |
380.0 W | Tie (0 W) | 47.94 V | 20.19% | 92.0% |
What Are the Design Limits and Best-Fit Uses for Caterpillar Inc PVC380MP03?
Evaluate Caterpillar Inc PVC380MP03 (380.0 W STC, 49.03 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Caterpillar Inc PVC380MP03 reaches 54.83 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 445 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (445 sq ft).
- 2026 tax credit baseline: cash residential installs of Caterpillar Inc PVC380MP03 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Caterpillar Inc PVC380MP03 8 kW Residential Fit
Needs 22 modules (445 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Crossroads Solar Crossroads Solar 380.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 355.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Caterpillar Inc PVC380MP03 by Caterpillar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
How many Caterpillar Inc PVC380MP03 panels fit on a 600 V winter solar string?
At -10 C (14 F), Caterpillar Inc PVC380MP03 cold Voc rises from 49.03 V to 53.54 V (beta_Voc -0.263%/C), capping a 600 V string at 11 panels (588.9 V).
How much roof area does an 8 kW array of Caterpillar Inc PVC380MP03 need?
An 8 kW DC system uses 22 Caterpillar Inc PVC380MP03 modules (8,360 W STC / 7,814 W PTC), covering roughly 445 sq ft and saving ~$2,092/yr at 18.54 c/kWh.
How does Caterpillar Inc PVC380MP03 compare against Crossroads Solar Crossroads Solar 380?
Caterpillar Inc PVC380MP03 outputs 380.0 W STC (49.03 V Voc, rank #11,043 of 21,677), while Crossroads Solar Crossroads Solar 380 delivers 380.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)