Caterpillar Inc PVT112 is a 112.5 W STC (104.5 W PTC) Thin Film solar module ranking #21,521 of 21,677 CEC listings (below all-CEC median; higher than 0.7% of peers). It delivers 15.62% efficiency, 87.7 V Voc at 25 C, and 95.93 V cold Voc at -10 C (6 panels max per 600 V string).
- STC Wattage
- 112.5 W
- PTC Wattage
- 104.5 W
- Voc @ 25C
- 87.7 V
- Efficiency
- 15.62%
How Does Caterpillar Inc PVT112 Compare Against Peer CEC Listings?
How Caterpillar Inc Caterpillar Inc PVT112 handles rooftop heat (104.5 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Caterpillar Inc PVT112 exhibits 1.75 A short-circuit current, requiring a 2.73 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #21,521 of 21,677 (5.0 W below the 117.5 W Thin Film median), this compact residential or specialty off-grid module covers 51.8 m2 for an 8 kW system (89 panels for 10 kW). Higher 87.7 V open-circuit voltage caps 600 V residential strings at 6 panels at 14 F (-10 C).
Where Does Caterpillar Inc PVT112 Fall Across Listed CEC Models?
Where Caterpillar Inc PVT112 (112.5 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Caterpillar Inc PVT112?
Percentile placement of Caterpillar Inc PVT112 across power density (156.2 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Caterpillar Inc PVT112?
Four critical engineering numbers homeowners and solar installers check first when reviewing Caterpillar Inc PVT112 specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
112.5 W STC · Higher Than 0.7%
112.5 W STC (-272.5 W vs all-CEC median) vs 117.5 W Thin Film median.
15.62% Aperture Efficiency
Power density 156.2 W/m2 (4.29 percentage points below 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).
6 Panels Max @ -10 C (600 V)
Cold Voc reaches 95.93 V at -10 C (575.6 V string) and 98.28 V at -20 C (6 max).
72 Panels = 8,100 W STC
Occupies 51.8 m2 (558 sq ft) producing 7,524 W PTC; NEC 690.8 OCPD floor is 2.73 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 87.7 * (1 + (-0.268/100) * (-10 - 25)) = 95.93 V | OCPD = 1.56 * 1.75 = 2.73 A
Inputs from CEC Modules.csv for Caterpillar Inc PVT112: Voc=87.7 V, beta_Voc=-0.268%/C, Isc=1.75 A, STC=112.5 W, Area=0.72 m2.
Result: 6 panels max on 600 V (575.6 V); 72 panels for 8 kW (558 sq ft).
What Are the Published CEC Specifications for Caterpillar Inc PVT112?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Caterpillar Inc PVT112.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 112.5 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 104.5 W (92.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 87.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 1.75 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 70.2 V / 1.6 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.268 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.62% (0.72 m2) | Array roof footprint density |
| Cell Count & Technology | 216 cells (Thin Film) | Monofacial backsheet |
How Many Caterpillar Inc PVT112 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Caterpillar Inc PVT112 (112.5 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 54 | 6.08 kW | 419 sq ft | $1,522 | $2,573 |
| 8 kW Class | 72 | 8.1 kW | 558 sq ft | $2,027 | $3,428 |
| 10 kW Class | 89 | 10.01 kW | 690 sq ft | $2,505 | $4,236 |
Which Sibling Wattage & Trim Variants Belong to This Caterpillar Inc Series?
All closely matched Caterpillar Inc wattages and cosmetic trims sharing the Caterpillar Inc PVT112 architecture. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Caterpillar Inc PVT105 | 105.0 W | 97.4 W | 86.0 V | 67.8 V | 14.58% |
| Caterpillar Inc PVT107 | 107.5 W | 99.7 W | 86.6 V | 68.6 V | 14.93% |
| Caterpillar Inc PVT110 | 110.0 W | 102.1 W | 87.2 V | 69.4 V | 15.28% |
| Caterpillar Inc PVT112 | 112.5 W | 104.5 W | 87.7 V | 70.2 V | 15.62% |
| Caterpillar Inc PVT115 | 115.0 W | 105.2 W | 87.8 V | 70.5 V | 15.97% |
| Caterpillar Inc PVT117 | 117.5 W | 107.5 W | 88.2 V | 71.2 V | 16.32% |
How Many Caterpillar Inc PVT112 Modules Fit in a Cold-Weather String?
Maximum series module counts for Caterpillar Inc PVT112 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 98.28 V | 6 panels | 589.7 V | 10 panels |
| -10 C (14 F) | 95.93 V | 6 panels | 575.6 V | 10 panels |
| 0 C (32 F) | 93.58 V | 6 panels | 561.5 V | 10 panels |
| 25 C (77 F STC) | 87.7 V | 6 panels | 526.2 V | 11 panels |
Which Cross-Brand Solar Modules Compare Closest to Caterpillar Inc PVT112?
Alternative CEC solar modules from competing brands near Caterpillar Inc PVT112 (112.5 W), including First Solar Inc FS-4112-2.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| First Solar Inc FS-4112-2 First Solar Inc |
112.5 W | Tie (0 W) | 87.7 V | 15.62% | 92.9% |
| First Solar Inc FS-4112A-2 First Solar Inc |
112.5 W | Tie (0 W) | 87.7 V | 15.62% | 92.9% |
| First Solar Inc FS-4112-3 First Solar Inc |
112.5 W | Tie (0 W) | 87.0 V | 15.62% | 93.2% |
| First Solar Inc FS-4112A-3 First Solar Inc |
112.5 W | Tie (0 W) | 87.0 V | 15.62% | 93.2% |
What Are the Design Limits and Best-Fit Uses for Caterpillar Inc PVT112?
Evaluate Caterpillar Inc PVT112 (112.5 W STC, 87.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Caterpillar Inc PVT112 reaches 98.28 V per panel—exceeding 6 panels in series voids 600 V inverter warranties.
- Footprint constraint: 72 panels for an 8 kW build require 558 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 72 panels (558 sq ft).
- 2026 tax credit baseline: cash residential installs of Caterpillar Inc PVT112 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Caterpillar Inc PVT112 8 kW Residential Fit
Needs 72 modules (558 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 6 panels (-10 C) or 6 panels (-20 C), or compare First Solar Inc FS-4112-2.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 104.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Caterpillar Inc PVT112 by Caterpillar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Caterpillar Inc PVT112 PTC wattage (104.5 W) lower than STC (112.5 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 104.5 W PTC (92.9% retention) across Caterpillar Inc PVT112's 0.72 m2 aperture.
Who should skip Caterpillar Inc PVT112 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 72 Caterpillar Inc PVT112 panels (558 sq ft) leave unusable roof gaps vs. First Solar Inc FS-4112-2.
What is the 1,000 V commercial string limit for Caterpillar Inc PVT112?
On 1,000 V commercial inverters at -10 C (95.93 V cold Voc), Caterpillar Inc PVT112 fits up to 10 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Caterpillar Inc PVT112.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)