First Solar Inc FS-4112-2 is a 112.5 W STC (104.5 W PTC) Thin Film solar module ranking #21,521 of 21,677 CEC listings (below all-CEC median; higher than 0.7% of peers). It delivers 15.62% efficiency, 87.7 V Voc at 25 C, and 95.93 V cold Voc at -10 C (6 panels max per 600 V string).
- STC Wattage
- 112.5 W
- PTC Wattage
- 104.5 W
- Voc @ 25C
- 87.7 V
- Efficiency
- 15.62%
How Does First Solar Inc FS-4112-2 Compare Against Peer CEC Listings?
Solar engineering breakdown for First Solar Inc FS-4112-2: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 106 Thin Film listings from First Solar Inc and peers, First Solar Inc FS-4112-2 stands 5.0 W below the 117.5 W Thin Film median and strong 92.9% PTC-to-STC heat retention (#10,348 of 21,677). Sizing 6 kW (54 panels) to 10 kW (89 panels) yields $1,522-$2,505/yr in baseline US bill offset. Higher 87.7 V open-circuit voltage caps 600 V residential strings at 6 panels at 14 F (-10 C).
Where Does First Solar Inc FS-4112-2 Fall Across Listed CEC Models?
Distribution marker showing First Solar Inc FS-4112-2 (112.5 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define First Solar Inc FS-4112-2?
Dataset percentiles tracking First Solar Inc FS-4112-2 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for First Solar Inc FS-4112-2?
Benchmark highlights for First Solar Inc FS-4112-2 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
112.5 W STC · Higher Than 0.7%
112.5 W STC (-272.5 W vs all-CEC median) vs 117.5 W Thin Film median.
15.62% Aperture Efficiency
Power density 156.2 W/m2 (4.29 percentage points below 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).
6 Panels Max @ -10 C (600 V)
Cold Voc reaches 95.93 V at -10 C (575.6 V string) and 98.28 V at -20 C (6 max).
72 Panels = 8,100 W STC
Occupies 51.8 m2 (558 sq ft) producing 7,524 W PTC; NEC 690.8 OCPD floor is 2.73 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 87.7 * (1 + (-0.268/100) * (-10 - 25)) = 95.93 V | OCPD = 1.56 * 1.75 = 2.73 A
Inputs from CEC Modules.csv for First Solar Inc FS-4112-2: Voc=87.7 V, beta_Voc=-0.268%/C, Isc=1.75 A, STC=112.5 W, Area=0.72 m2.
Result: 6 panels max on 600 V (575.6 V); 72 panels for 8 kW (558 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-4112-2?
Official CEC datasheet figures for First Solar Inc FS-4112-2 (Thin Film) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 112.5 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 104.5 W (92.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 87.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 1.75 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 70.2 V / 1.6 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.268 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.62% (0.72 m2) | Array roof footprint density |
| Cell Count & Technology | 216 cells (Thin Film) | Monofacial backsheet |
How Many First Solar Inc FS-4112-2 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many First Solar Inc FS-4112-2 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 54 | 6.08 kW | 419 sq ft | $1,522 | $2,573 |
| 8 kW Class | 72 | 8.1 kW | 558 sq ft | $2,027 | $3,428 |
| 10 kW Class | 89 | 10.01 kW | 690 sq ft | $2,505 | $4,236 |
How Many First Solar Inc FS-4112-2 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on First Solar Inc FS-4112-2 (95.93 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 98.28 V | 6 panels | 589.7 V | 10 panels |
| -10 C (14 F) | 95.93 V | 6 panels | 575.6 V | 10 panels |
| 0 C (32 F) | 93.58 V | 6 panels | 561.5 V | 10 panels |
| 25 C (77 F STC) | 87.7 V | 6 panels | 526.2 V | 11 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-4112-2?
Competing CEC solar panels closest to First Solar Inc FS-4112-2 in nameplate wattage and Voc, starting with Caterpillar Inc PVT112.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Caterpillar Inc PVT112 Caterpillar Inc |
112.5 W | Tie (0 W) | 87.7 V | 15.62% | 92.9% |
| Caterpillar Inc PVT112 ARC Caterpillar Inc |
112.5 W | Tie (0 W) | 87.7 V | 15.62% | 92.9% |
| Toledo Solar Inc TS1 Toledo Solar Inc |
115.0 W | +2.5 W | 87.1 V | 15.97% | 92.9% |
| T-Solar Global TS102 T-Solar Global |
102.5 W | -10.0 W | 93.0 V | 7.19% | 93.0% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-4112-2?
Evaluate First Solar Inc FS-4112-2 (112.5 W STC, 87.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-4112-2 reaches 98.28 V per panel—exceeding 6 panels in series voids 600 V inverter warranties.
- Footprint constraint: 72 panels for an 8 kW build require 558 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 72 panels (558 sq ft).
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-4112-2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-4112-2 8 kW Residential Fit
Needs 72 modules (558 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 6 panels (-10 C) or 6 panels (-20 C), or compare Caterpillar Inc PVT112.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 104.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-4112-2 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for First Solar Inc FS-4112-2?
Multiplying First Solar Inc FS-4112-2's 1.75 A short-circuit current by 1.56 equals 2.73 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can First Solar Inc FS-4112-2 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 95.93 V cold Voc at 14 F and handles 1.75 A Isc; string inverters cap First Solar Inc FS-4112-2 at 6 panels on 600 V.
Is First Solar Inc FS-4112-2 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of First Solar Inc FS-4112-2 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)