T-Solar Global TS102 — CEC Solar Module Specifications

Manufacturer: T-Solar Global Registry: CEC Verified Engineering Specification

T-Solar Global TS102 is a 102.5 W STC (95.3 W PTC) Thin Film solar module ranking #21,557 of 21,677 CEC listings (below all-CEC median; higher than 0.5% of peers). It delivers 7.19% efficiency, 93.0 V Voc at 25 C, and 103.74 V cold Voc at -10 C (5 panels max per 600 V string).

STC Wattage
102.5 W
PTC Wattage
95.3 W
Voc @ 25C
93.0 V
Efficiency
7.19%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does T-Solar Global TS102 Compare Against Peer CEC Listings?

Solar engineering breakdown for T-Solar Global TS102: PTC thermal retention, roof footprint, and cold Voc string bounds. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Across 106 Thin Film listings from T-Solar Global and peers, T-Solar Global TS102 stands 15.0 W below the 117.5 W Thin Film median and strong 93.0% PTC-to-STC heat retention (#9,879 of 21,677). Sizing 6 kW (59 panels) to 10 kW (98 panels) yields $1,514-$2,513/yr in baseline US bill offset. Higher 93.0 V open-circuit voltage caps 600 V residential strings at 5 panels at 14 F (-10 C).

Where Does T-Solar Global TS102 Fall Across Listed CEC Models?

Distribution marker showing T-Solar Global TS102 (102.5 W) relative to the 385.0 W all-CEC solar panel median. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where T-Solar Global TS102 (102.5 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCT-Solar Global TS1: 102.5 W

What Dataset Percentiles Define T-Solar Global TS102?

Dataset percentiles tracking T-Solar Global TS102 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

T-Solar Global TS102 Engineering BenchmarksPercentile comparison of T-Solar Global TS102 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage102.5 WPTC/STC Retention93.0%Module Efficiency7.19%

What Do the Dataset Ranks Show for T-Solar Global TS102?

Benchmark highlights for T-Solar Global TS102 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Rank #21,557 / 21,677

102.5 W STC · Higher Than 0.5%

102.5 W STC (-282.5 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #21,661

7.19% Aperture Efficiency

Power density 71.9 W/m2 (12.72 percentage points below 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).

NEC 690.7 Limit

5 Panels Max @ -10 C (600 V)

Cold Voc reaches 103.74 V at -10 C (518.7 V string) and 106.81 V at -20 C (5 max).

8 kW Reference Array

79 Panels = 8,098 W STC

Occupies 112.6 m2 (1,212 sq ft) producing 7,529 W PTC; NEC 690.8 OCPD floor is 2.64 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 93.0 * (1 + (-0.33/100) * (-10 - 25)) = 103.74 V | OCPD = 1.56 * 1.69 = 2.64 A

Inputs from CEC Modules.csv for T-Solar Global TS102: Voc=93.0 V, beta_Voc=-0.33%/C, Isc=1.69 A, STC=102.5 W, Area=1.425 m2.

Result: 5 panels max on 600 V (518.7 V); 79 panels for 8 kW (1,212 sq ft).

What Are the Published CEC Specifications for T-Solar Global TS102?

Official CEC datasheet figures for T-Solar Global TS102 (Thin Film) used in utility interconnection and permit reviews. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Official California Energy Commission (NREL SAM) test parameters for T-Solar Global TS102.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 102.5 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 95.3 W (93.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 93.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 1.69 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 72.0 V / 1.43 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.33 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 7.19% (1.425 m2) Array roof footprint density
Cell Count & Technology 106 cells (Thin Film) Monofacial backsheet

How Many T-Solar Global TS102 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many T-Solar Global TS102 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 59 6.05 kW 905 sq ft $1,514 $2,561
8 kW Class 79 8.1 kW 1,212 sq ft $2,027 $3,428
10 kW Class 98 10.04 kW 1,503 sq ft $2,513 $4,249

How Many T-Solar Global TS102 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on T-Solar Global TS102 (103.74 V at 14 F).

Computed from Voc=93.0V and beta_Voc=-0.33%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 106.81 V 5 panels 534.0 V 9 panels
-10 C (14 F) 103.74 V 5 panels 518.7 V 9 panels
0 C (32 F) 100.67 V 5 panels 503.4 V 9 panels
25 C (77 F STC) 93.0 V 6 panels 558.0 V 10 panels

Which Cross-Brand Solar Modules Compare Closest to T-Solar Global TS102?

Competing CEC solar panels closest to T-Solar Global TS102 in nameplate wattage and Voc, starting with First Solar Inc FS-4102.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
First Solar Inc FS-4102
First Solar Inc
102.5 W Tie (0 W) 88.0 V 14.24% 94.5%
First Solar Inc FS-4102A
First Solar Inc
102.5 W Tie (0 W) 88.0 V 14.24% 94.5%
First Solar Inc FS-4105
First Solar Inc
105.0 W +2.5 W 88.2 V 14.58% 94.6%
First Solar Inc FS-4105A
First Solar Inc
105.0 W +2.5 W 88.2 V 14.58% 94.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for T-Solar Global TS102?

Evaluate T-Solar Global TS102 (102.5 W STC, 93.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), T-Solar Global TS102 reaches 106.81 V per panel—exceeding 5 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 79 panels for an 8 kW build require 1,212 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 79 panels (1,212 sq ft).
  • 2026 tax credit baseline: cash residential installs of T-Solar Global TS102 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

T-Solar Global TS102 8 kW Residential Fit

Needs 79 modules (1,212 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 5 panels (-10 C) or 5 panels (-20 C), or compare First Solar Inc FS-4102.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 95.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for T-Solar Global TS102 by T-Solar Global grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for T-Solar Global TS102?

Multiplying T-Solar Global TS102's 1.69 A short-circuit current by 1.56 equals 2.64 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can T-Solar Global TS102 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 103.74 V cold Voc at 14 F and handles 1.69 A Isc; string inverters cap T-Solar Global TS102 at 5 panels on 600 V.

Is T-Solar Global TS102 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of T-Solar Global TS102 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.