Skip to main content
WireAndSun
Calculators
CEC PV Module

T-Solar Global TS390 — CEC Solar Module Specifications

Manufacturer: T-Solar Global Registry: CEC Verified Engineering Specification

T-Solar Global TS390 is a 390.0 W STC (362.3 W PTC) Thin Film solar module ranking #10,321 of 21,677 CEC listings (top 49.5%; higher than 50.5% of peers). It delivers 6.83% efficiency, 190.0 V Voc at 25 C, and 211.94 V cold Voc at -10 C (2 panels max per 600 V string).

STC Wattage
390.0 W
PTC Wattage
362.3 W
Voc @ 25C
190.0 V
Efficiency
6.83%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does T-Solar Global TS390 Compare Against Peer CEC Listings?

Engineering position of T-Solar Global TS390 (390.0 W STC) vs. CSI Solar Co Ltd CS1Y-390MS across 106 CEC Thin Film solar modules.

Ranking #10,321 across 21,677 CEC solar panels (top 49.5%; higher than 50.5% of peers), T-Solar Global TS390 operates as a modern high-density residential and light-commercial module sitting 272.5 W above the 117.5 W Thin Film median. Higher 190.0 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C). With strong 92.9% PTC-to-STC heat retention (#10,348 of 21,677), 21 panels occupy 1,291 sq ft and offset roughly $2,050/yr at average US rates (or $3,466/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does T-Solar Global TS390 Fall Across Listed CEC Models?

Plots T-Solar Global TS390 at 390.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where T-Solar Global TS390 (390.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCT-Solar Global TS3: 390.0 W

What Dataset Percentiles Define T-Solar Global TS390?

Benchmarks T-Solar Global TS390 on STC wattage, thermal PTC/STC retention, and 6.83 aperture conversion efficiency against CEC peers.

T-Solar Global TS390 Engineering BenchmarksPercentile comparison of T-Solar Global TS390 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage390.0 WPTC/STC Retention92.9%Module Efficiency6.83%

What Do the Dataset Ranks Show for T-Solar Global TS390?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for T-Solar Global TS390 by T-Solar Global.

Rank #10,321 / 21,677

Top 49.5% STC Output

390.0 W STC (+5.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #21,665

6.83% Aperture Efficiency

Power density 68.3 W/m2 (13.08 percentage points below 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).

NEC 690.7 Limit

2 Panels Max @ -10 C (600 V)

Cold Voc reaches 211.94 V at -10 C (423.9 V string) and 218.22 V at -20 C (2 max).

8 kW Reference Array

21 Panels = 8,190 W STC

Occupies 119.9 m2 (1,291 sq ft) producing 7,608 W PTC; NEC 690.8 OCPD floor is 5.05 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 190.0 * (1 + (-0.33/100) * (-10 - 25)) = 211.94 V | OCPD = 1.56 * 3.24 = 5.05 A

Inputs from CEC Modules.csv for T-Solar Global TS390: Voc=190.0 V, beta_Voc=-0.33%/C, Isc=3.24 A, STC=390.0 W, Area=5.71 m2.

Result: 2 panels max on 600 V (423.9 V); 21 panels for 8 kW (1,291 sq ft).

What Are the Published CEC Specifications for T-Solar Global TS390?

Laboratory test ratings recorded for T-Solar Global TS390 (Thin Film) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for T-Solar Global TS390.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 390.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 362.3 W (92.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 190.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 3.24 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 148.0 V / 2.74 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.33 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 6.83% (5.71 m2) Array roof footprint density
Cell Count & Technology 216 cells (Thin Film) Monofacial backsheet

How Many T-Solar Global TS390 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (1,291 sq ft at 8 kW), and estimated Year-1 electric bill offset for T-Solar Global TS390.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.24 kW 983 sq ft $1,562 $2,641
8 kW Class 21 8.19 kW 1,291 sq ft $2,050 $3,466
10 kW Class 26 10.14 kW 1,598 sq ft $2,538 $4,292

How Many T-Solar Global TS390 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for T-Solar Global TS390 (beta_Voc -0.33%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=190.0V and beta_Voc=-0.33%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 218.22 V 2 panels 436.4 V 4 panels
-10 C (14 F) 211.94 V 2 panels 423.9 V 4 panels
0 C (32 F) 205.68 V 2 panels 411.4 V 4 panels
25 C (77 F STC) 190.0 V 3 panels 570.0 V 5 panels

Which Cross-Brand Solar Modules Compare Closest to T-Solar Global TS390?

Closest cross-brand CEC competitors to T-Solar Global TS390 matched near 390.0 W STC and 190.0 V Voc, led by CSI Solar Co Ltd CS1Y-390MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS1Y-390MS
CSI Solar Co Ltd
390.0 W Tie (0 W) 51.9 V 20.0% 94.0%
BYD Company Limited BYD415MIK-36
BYD Company Limited
395.0 W +5.0 W 50.06 V 19.65% 93.9%
ELITE Solar ET-M672BH395GL
ELITE Solar
395.0 W +5.0 W 49.6 V 19.36% 93.2%
ELITE Solar ET-M672BH395WW
ELITE Solar
395.0 W +5.0 W 49.5 V 19.85% 93.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for T-Solar Global TS390?

Evaluate T-Solar Global TS390 (390.0 W STC, 190.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), T-Solar Global TS390 reaches 218.22 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 1,291 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (1,291 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of T-Solar Global TS390 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

T-Solar Global TS390 8 kW Residential Fit

Needs 21 modules (1,291 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare CSI Solar Co Ltd CS1Y-390MS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 362.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for T-Solar Global TS390 by T-Solar Global grounded in CEC test data and NEC 690.7/690.8 limits.

How many T-Solar Global TS390 panels fit on a 600 V winter solar string?

At -10 C (14 F), T-Solar Global TS390 cold Voc rises from 190.0 V to 211.94 V (beta_Voc -0.33%/C), capping a 600 V string at 2 panels (423.9 V).

How much roof area does an 8 kW array of T-Solar Global TS390 need?

An 8 kW DC system uses 21 T-Solar Global TS390 modules (8,190 W STC / 7,608 W PTC), covering roughly 1,291 sq ft and saving ~$2,050/yr at 18.54 c/kWh.

How does T-Solar Global TS390 compare against CSI Solar Co Ltd CS1Y-390MS?

T-Solar Global TS390 outputs 390.0 W STC (190.0 V Voc, rank #10,321 of 21,677), while CSI Solar Co Ltd CS1Y-390MS delivers 390.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.