T-Solar Global TS410 is a 410.0 W STC (381.1 W PTC) Thin Film solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 7.18% efficiency, 191.0 V Voc at 25 C, and 213.06 V cold Voc at -10 C (2 panels max per 600 V string).
- STC Wattage
- 410.0 W
- PTC Wattage
- 381.1 W
- Voc @ 25C
- 191.0 V
- Efficiency
- 7.18%
How Does T-Solar Global TS410 Compare Against Peer CEC Listings?
How T-Solar Global T-Solar Global TS410 handles rooftop heat (381.1 W PTC), 8 kW sizing, and cold winter string voltage.
T-Solar Global builds the T-Solar Global TS410 (Thin Film) as a modern high-density residential and light-commercial module delivering 71.8 W/m2 (12.73 percentage points below 19.91% CEC median). Compared against Applied Materials Full Size Single Junction Version 10 (414.0 W), this model holds strong 93.0% PTC-to-STC heat retention (#9,879 of 21,677). Higher 191.0 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C), while NEC 690.8 sets a 5.12 A overcurrent floor served by a 15 A breaker.
Where Does T-Solar Global TS410 Fall Across Listed CEC Models?
Where T-Solar Global TS410 (410.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define T-Solar Global TS410?
Percentile placement of T-Solar Global TS410 across power density (71.8 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for T-Solar Global TS410?
Four critical engineering numbers homeowners and solar installers check first when reviewing T-Solar Global TS410 specifications. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
Top 41.3% STC Output
410.0 W STC (+25.0 W vs all-CEC median) vs 117.5 W Thin Film median.
7.18% Aperture Efficiency
Power density 71.8 W/m2 (12.73 percentage points below 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).
2 Panels Max @ -10 C (600 V)
Cold Voc reaches 213.06 V at -10 C (426.1 V string) and 219.36 V at -20 C (2 max).
20 Panels = 8,200 W STC
Occupies 114.2 m2 (1,229 sq ft) producing 7,622 W PTC; NEC 690.8 OCPD floor is 5.12 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 191.0 * (1 + (-0.33/100) * (-10 - 25)) = 213.06 V | OCPD = 1.56 * 3.28 = 5.12 A
Inputs from CEC Modules.csv for T-Solar Global TS410: Voc=191.0 V, beta_Voc=-0.33%/C, Isc=3.28 A, STC=410.0 W, Area=5.71 m2.
Result: 2 panels max on 600 V (426.1 V); 20 panels for 8 kW (1,229 sq ft).
What Are the Published CEC Specifications for T-Solar Global TS410?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for T-Solar Global TS410.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 381.1 W (93.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 191.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 3.28 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 149.0 V / 2.78 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.33 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 7.18% (5.71 m2) | Array roof footprint density |
| Cell Count & Technology | 216 cells (Thin Film) | Monofacial backsheet |
How Many T-Solar Global TS410 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using T-Solar Global TS410 (410.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.15 kW | 922 sq ft | $1,539 | $2,603 |
| 8 kW Class | 20 | 8.2 kW | 1,229 sq ft | $2,052 | $3,470 |
| 10 kW Class | 25 | 10.25 kW | 1,537 sq ft | $2,565 | $4,338 |
How Many T-Solar Global TS410 Modules Fit in a Cold-Weather String?
Maximum series module counts for T-Solar Global TS410 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 219.36 V | 2 panels | 438.7 V | 4 panels |
| -10 C (14 F) | 213.06 V | 2 panels | 426.1 V | 4 panels |
| 0 C (32 F) | 206.76 V | 2 panels | 413.5 V | 4 panels |
| 25 C (77 F STC) | 191.0 V | 3 panels | 573.0 V | 5 panels |
Which Cross-Brand Solar Modules Compare Closest to T-Solar Global TS410?
Alternative CEC solar modules from competing brands near T-Solar Global TS410 (410.0 W), including Applied Materials Full Size Single Junction Version 10.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Applied Materials Full Size Single Junction Version 10 Applied Materials |
414.0 W | +4.0 W | 194.2 V | 7.24% | 92.9% |
| CSI Solar Co Ltd CS1Y-410MS CSI Solar Co Ltd |
410.0 W | Tie (0 W) | 52.7 V | 21.03% | 94.1% |
| Auxin Solar AXNG1M410B Auxin Solar |
410.0 W | Tie (0 W) | 49.47 V | 20.92% | 93.4% |
| Auxin Solar AXNG1M410W Auxin Solar |
410.0 W | Tie (0 W) | 49.47 V | 20.92% | 93.3% |
What Are the Design Limits and Best-Fit Uses for T-Solar Global TS410?
Evaluate T-Solar Global TS410 (410.0 W STC, 191.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), T-Solar Global TS410 reaches 219.36 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 1,229 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (1,229 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of T-Solar Global TS410 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
T-Solar Global TS410 8 kW Residential Fit
Needs 20 modules (1,229 sq ft) with a 15 A string OCPD, offsetting ~$2,052/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Single Junction Version 10.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 381.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for T-Solar Global TS410 by T-Solar Global grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for T-Solar Global TS410?
Multiplying T-Solar Global TS410's 3.28 A short-circuit current by 1.56 equals 5.12 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can T-Solar Global TS410 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 213.06 V cold Voc at 14 F and handles 3.28 A Isc; string inverters cap T-Solar Global TS410 at 2 panels on 600 V.
Is T-Solar Global TS410 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of T-Solar Global TS410 rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)