Applied Materials Full Size Single Junction Version 10 — CEC Solar Module Specifications

Manufacturer: Applied Materials Registry: CEC Verified Engineering Specification

Applied Materials Full Size Single Junction Version 10 is a 414.0 W STC (384.8 W PTC) Thin Film solar module ranking #8,538 of 21,677 CEC listings (top 39.4%; higher than 60.6% of peers). It delivers 7.24% efficiency, 194.2 V Voc at 25 C, and 216.63 V cold Voc at -10 C (2 panels max per 600 V string).

STC Wattage
414.0 W
PTC Wattage
384.8 W
Voc @ 25C
194.2 V
Efficiency
7.24%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Applied Materials Full Size Single Junction Version 10 Compare Against Peer CEC Listings?

How Applied Materials Applied Materials Full Size Single Junction Version 10 handles rooftop heat (384.8 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Applied Materials Full Size Single Junction Version 10 exhibits 2.9 A short-circuit current, requiring a 4.52 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #8,538 of 21,677 (296.5 W above the 117.5 W Thin Film median), this modern high-density residential and light-commercial module covers 114.4 m2 for an 8 kW system (25 panels for 10 kW). Higher 194.2 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C).

Where Does Applied Materials Full Size Single Junction Version 10 Fall Across Listed CEC Models?

Where Applied Materials Full Size Single Junction Version 10 (414.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Applied Materials Full Size Single Junction Version 10 (414.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCApplied Materials : 414.0 W

What Dataset Percentiles Define Applied Materials Full Size Single Junction Version 10?

Percentile placement of Applied Materials Full Size Single Junction Version 10 across power density (72.4 W/m2), thermal retention, and nameplate STC wattage.

Applied Materials Full Size Single Junction Version 10 Engineering BenchmarksPercentile comparison of Applied Materials Full Size Single Junction Version 10 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage414.0 WPTC/STC Retention92.9%Module Efficiency7.24%

What Do the Dataset Ranks Show for Applied Materials Full Size Single Junction Version 10?

Four critical engineering numbers homeowners and solar installers check first when reviewing Applied Materials Full Size Single Junction Version 10 specifications.

Rank #8,538 / 21,677

Top 39.4% STC Output

414.0 W STC (+29.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #21,658

7.24% Aperture Efficiency

Power density 72.4 W/m2 (12.67 percentage points below 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).

NEC 690.7 Limit

2 Panels Max @ -10 C (600 V)

Cold Voc reaches 216.63 V at -10 C (433.3 V string) and 223.04 V at -20 C (2 max).

8 kW Reference Array

20 Panels = 8,280 W STC

Occupies 114.4 m2 (1,231 sq ft) producing 7,696 W PTC; NEC 690.8 OCPD floor is 4.52 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 194.2 * (1 + (-0.33/100) * (-10 - 25)) = 216.63 V | OCPD = 1.56 * 2.9 = 4.52 A

Inputs from CEC Modules.csv for Applied Materials Full Size Single Junction Version 10: Voc=194.2 V, beta_Voc=-0.33%/C, Isc=2.9 A, STC=414.0 W, Area=5.72 m2.

Result: 2 panels max on 600 V (433.3 V); 20 panels for 8 kW (1,231 sq ft).

What Are the Published CEC Specifications for Applied Materials Full Size Single Junction Version 10?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Applied Materials Full Size Single Junction Version 10.

Official California Energy Commission (NREL SAM) test parameters for Applied Materials Full Size Single Junction Version 10.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 414.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 384.8 W (92.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 194.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 2.9 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 159.8 V / 2.59 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.33 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 7.24% (5.72 m2) Array roof footprint density
Cell Count & Technology 216 cells (Thin Film) Monofacial backsheet

How Many Applied Materials Full Size Single Junction Version 10 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Applied Materials Full Size Single Junction Version 10 (414.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.21 kW 924 sq ft $1,554 $2,628
8 kW Class 20 8.28 kW 1,231 sq ft $2,072 $3,504
10 kW Class 25 10.35 kW 1,539 sq ft $2,591 $4,380

How Many Applied Materials Full Size Single Junction Version 10 Modules Fit in a Cold-Weather String?

Maximum series module counts for Applied Materials Full Size Single Junction Version 10 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=194.2V and beta_Voc=-0.33%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 223.04 V 2 panels 446.1 V 4 panels
-10 C (14 F) 216.63 V 2 panels 433.3 V 4 panels
0 C (32 F) 210.22 V 2 panels 420.4 V 4 panels
25 C (77 F STC) 194.2 V 3 panels 582.6 V 5 panels

Which Cross-Brand Solar Modules Compare Closest to Applied Materials Full Size Single Junction Version 10?

Alternative CEC solar modules from competing brands near Applied Materials Full Size Single Junction Version 10 (414.0 W), including CSI Solar Co Ltd CS1Y-410MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS1Y-410MS
CSI Solar Co Ltd
410.0 W -4.0 W 52.7 V 21.03% 94.1%
Auxin Solar AXNG1M410B
Auxin Solar
410.0 W -4.0 W 49.47 V 20.92% 93.4%
Auxin Solar AXNG1M410W
Auxin Solar
410.0 W -4.0 W 49.47 V 20.92% 93.3%
Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W
Dehui Solar Power (Vietnam) CoLtd
410.0 W -4.0 W 49.4 V 21.47% 92.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Applied Materials Full Size Single Junction Version 10?

Evaluate Applied Materials Full Size Single Junction Version 10 (414.0 W STC, 194.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Applied Materials Full Size Single Junction Version 10 reaches 223.04 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 1,231 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (1,231 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Applied Materials Full Size Single Junction Version 10 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Applied Materials Full Size Single Junction Version 10 8 kW Residential Fit

Needs 20 modules (1,231 sq ft) with a 15 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare CSI Solar Co Ltd CS1Y-410MS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 384.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Applied Materials Full Size Single Junction Version 10 by Applied Materials grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Applied Materials Full Size Single Junction Version 10 PTC wattage (384.8 W) lower than STC (414.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 384.8 W PTC (92.9% retention) across Applied Materials Full Size Single Junction Version 10's 5.72 m2 aperture.

Who should skip Applied Materials Full Size Single Junction Version 10 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 Applied Materials Full Size Single Junction Version 10 panels (1,231 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS1Y-410MS.

What is the 1,000 V commercial string limit for Applied Materials Full Size Single Junction Version 10?

On 1,000 V commercial inverters at -10 C (216.63 V cold Voc), Applied Materials Full Size Single Junction Version 10 fits up to 4 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.