Applied Materials 1/2-P Size Single Junction Version 10 is a 207.0 W STC (192.4 W PTC) Thin Film solar module ranking #20,976 of 21,677 CEC listings (below all-CEC median; higher than 3.2% of peers). It delivers 7.24% efficiency, 97.1 V Voc at 25 C, and 108.32 V cold Voc at -10 C (5 panels max per 600 V string).
- STC Wattage
- 207.0 W
- PTC Wattage
- 192.4 W
- Voc @ 25C
- 97.1 V
- Efficiency
- 7.24%
How Does Applied Materials 1/2-P Size Single Junction Version 10 Compare Against Peer CEC Listings?
Solar engineering breakdown for Applied Materials 1/2-P Size Single Junction Version 10: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 106 Thin Film listings from Applied Materials and peers, Applied Materials 1/2-P Size Single Junction Version 10 stands 89.5 W above the 117.5 W Thin Film median and strong 92.9% PTC-to-STC heat retention (#10,348 of 21,677). Sizing 6 kW (29 panels) to 10 kW (49 panels) yields $1,502-$2,538/yr in baseline US bill offset. Higher 97.1 V open-circuit voltage caps 600 V residential strings at 5 panels at 14 F (-10 C).
Where Does Applied Materials 1/2-P Size Single Junction Version 10 Fall Across Listed CEC Models?
Distribution marker showing Applied Materials 1/2-P Size Single Junction Version 10 (207.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Applied Materials 1/2-P Size Single Junction Version 10?
Dataset percentiles tracking Applied Materials 1/2-P Size Single Junction Version 10 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Applied Materials 1/2-P Size Single Junction Version 10?
Benchmark highlights for Applied Materials 1/2-P Size Single Junction Version 10 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
207.0 W STC · Higher Than 3.2%
207.0 W STC (-178.0 W vs all-CEC median) vs 117.5 W Thin Film median.
7.24% Aperture Efficiency
Power density 72.4 W/m2 (12.67 percentage points below 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).
5 Panels Max @ -10 C (600 V)
Cold Voc reaches 108.32 V at -10 C (541.6 V string) and 111.52 V at -20 C (5 max).
39 Panels = 8,073 W STC
Occupies 111.5 m2 (1,201 sq ft) producing 7,504 W PTC; NEC 690.8 OCPD floor is 4.52 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 97.1 * (1 + (-0.33/100) * (-10 - 25)) = 108.32 V | OCPD = 1.56 * 2.9 = 4.52 A
Inputs from CEC Modules.csv for Applied Materials 1/2-P Size Single Junction Version 10: Voc=97.1 V, beta_Voc=-0.33%/C, Isc=2.9 A, STC=207.0 W, Area=2.86 m2.
Result: 5 panels max on 600 V (541.6 V); 39 panels for 8 kW (1,201 sq ft).
What Are the Published CEC Specifications for Applied Materials 1/2-P Size Single Junction Version 10?
Official CEC datasheet figures for Applied Materials 1/2-P Size Single Junction Version 10 (Thin Film) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 207.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 192.4 W (92.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 97.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 2.9 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 79.9 V / 2.59 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.33 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 7.24% (2.86 m2) | Array roof footprint density |
| Cell Count & Technology | 106 cells (Thin Film) | Monofacial backsheet |
How Many Applied Materials 1/2-P Size Single Junction Version 10 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Applied Materials 1/2-P Size Single Junction Version 10 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 29 | 6.0 kW | 893 sq ft | $1,502 | $2,539 |
| 8 kW Class | 39 | 8.07 kW | 1,201 sq ft | $2,020 | $3,415 |
| 10 kW Class | 49 | 10.14 kW | 1,508 sq ft | $2,538 | $4,292 |
How Many Applied Materials 1/2-P Size Single Junction Version 10 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Applied Materials 1/2-P Size Single Junction Version 10 (108.32 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 111.52 V | 5 panels | 557.6 V | 8 panels |
| -10 C (14 F) | 108.32 V | 5 panels | 541.6 V | 9 panels |
| 0 C (32 F) | 105.11 V | 5 panels | 525.5 V | 9 panels |
| 25 C (77 F STC) | 97.1 V | 6 panels | 582.6 V | 10 panels |
Which Cross-Brand Solar Modules Compare Closest to Applied Materials 1/2-P Size Single Junction Version 10?
Competing CEC solar panels closest to Applied Materials 1/2-P Size Single Junction Version 10 in nameplate wattage and Voc, starting with Grape Solar GS-S-220-CS.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Grape Solar GS-S-220-CS Grape Solar |
220.0 W | +13.0 W | 59.4 V | 12.94% | 91.0% |
| Exeltech AM24-1-B-6-0-00 Exeltech |
240.0 W | +33.0 W | 59.5 V | 14.12% | 88.3% |
| Grape Solar GS-S-240-CS Grape Solar |
240.0 W | +33.0 W | 59.3 V | 14.12% | 91.1% |
| Eoplly New Energy Technology EP125M/72-205W Eoplly New Energy Technology |
205.0 W | -2.0 W | 46.21 V | 16.06% | 89.0% |
What Are the Design Limits and Best-Fit Uses for Applied Materials 1/2-P Size Single Junction Version 10?
Evaluate Applied Materials 1/2-P Size Single Junction Version 10 (207.0 W STC, 97.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Applied Materials 1/2-P Size Single Junction Version 10 reaches 111.52 V per panel—exceeding 5 panels in series voids 600 V inverter warranties.
- Footprint constraint: 39 panels for an 8 kW build require 1,201 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 39 panels (1,201 sq ft).
- 2026 tax credit baseline: cash residential installs of Applied Materials 1/2-P Size Single Junction Version 10 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Applied Materials 1/2-P Size Single Junction Version 10 8 kW Residential Fit
Needs 39 modules (1,201 sq ft) with a 15 A string OCPD, offsetting ~$2,020/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 5 panels (-10 C) or 5 panels (-20 C), or compare Grape Solar GS-S-220-CS.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 192.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Applied Materials 1/2-P Size Single Junction Version 10 by Applied Materials grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Applied Materials 1/2-P Size Single Junction Version 10?
Multiplying Applied Materials 1/2-P Size Single Junction Version 10's 2.9 A short-circuit current by 1.56 equals 4.52 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Applied Materials 1/2-P Size Single Junction Version 10 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 108.32 V cold Voc at 14 F and handles 2.9 A Isc; string inverters cap Applied Materials 1/2-P Size Single Junction Version 10 at 5 panels on 600 V.
Is Applied Materials 1/2-P Size Single Junction Version 10 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Applied Materials 1/2-P Size Single Junction Version 10 rely on utility bill offset (~$2,020/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)