Skip to main content
WireAndSun
Calculators
CEC PV Module

Applied Materials 1/2-P Size Single Junction Version 10 — CEC Solar Module Specifications

Manufacturer: Applied Materials Registry: CEC Verified Engineering Specification

Applied Materials 1/2-P Size Single Junction Version 10 is a 207.0 W STC (192.4 W PTC) Thin Film solar module ranking #20,976 of 21,677 CEC listings (below all-CEC median; higher than 3.2% of peers). It delivers 7.24% efficiency, 97.1 V Voc at 25 C, and 108.32 V cold Voc at -10 C (5 panels max per 600 V string).

STC Wattage
207.0 W
PTC Wattage
192.4 W
Voc @ 25C
97.1 V
Efficiency
7.24%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Applied Materials 1/2-P Size Single Junction Version 10 Compare Against Peer CEC Listings?

Solar engineering breakdown for Applied Materials 1/2-P Size Single Junction Version 10: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 106 Thin Film listings from Applied Materials and peers, Applied Materials 1/2-P Size Single Junction Version 10 stands 89.5 W above the 117.5 W Thin Film median and strong 92.9% PTC-to-STC heat retention (#10,348 of 21,677). Sizing 6 kW (29 panels) to 10 kW (49 panels) yields $1,502-$2,538/yr in baseline US bill offset. Higher 97.1 V open-circuit voltage caps 600 V residential strings at 5 panels at 14 F (-10 C).

Where Does Applied Materials 1/2-P Size Single Junction Version 10 Fall Across Listed CEC Models?

Distribution marker showing Applied Materials 1/2-P Size Single Junction Version 10 (207.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Applied Materials 1/2-P Size Single Junction Version 10 (207.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCApplied Materials : 207.0 W

What Dataset Percentiles Define Applied Materials 1/2-P Size Single Junction Version 10?

Dataset percentiles tracking Applied Materials 1/2-P Size Single Junction Version 10 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Applied Materials 1/2-P Size Single Junction Version 10 Engineering BenchmarksPercentile comparison of Applied Materials 1/2-P Size Single Junction Version 10 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage207.0 WPTC/STC Retention92.9%Module Efficiency7.24%

What Do the Dataset Ranks Show for Applied Materials 1/2-P Size Single Junction Version 10?

Benchmark highlights for Applied Materials 1/2-P Size Single Junction Version 10 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #20,976 / 21,677

207.0 W STC · Higher Than 3.2%

207.0 W STC (-178.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #21,658

7.24% Aperture Efficiency

Power density 72.4 W/m2 (12.67 percentage points below 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).

NEC 690.7 Limit

5 Panels Max @ -10 C (600 V)

Cold Voc reaches 108.32 V at -10 C (541.6 V string) and 111.52 V at -20 C (5 max).

8 kW Reference Array

39 Panels = 8,073 W STC

Occupies 111.5 m2 (1,201 sq ft) producing 7,504 W PTC; NEC 690.8 OCPD floor is 4.52 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 97.1 * (1 + (-0.33/100) * (-10 - 25)) = 108.32 V | OCPD = 1.56 * 2.9 = 4.52 A

Inputs from CEC Modules.csv for Applied Materials 1/2-P Size Single Junction Version 10: Voc=97.1 V, beta_Voc=-0.33%/C, Isc=2.9 A, STC=207.0 W, Area=2.86 m2.

Result: 5 panels max on 600 V (541.6 V); 39 panels for 8 kW (1,201 sq ft).

What Are the Published CEC Specifications for Applied Materials 1/2-P Size Single Junction Version 10?

Official CEC datasheet figures for Applied Materials 1/2-P Size Single Junction Version 10 (Thin Film) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Applied Materials 1/2-P Size Single Junction Version 10.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 207.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 192.4 W (92.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 97.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 2.9 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 79.9 V / 2.59 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.33 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 7.24% (2.86 m2) Array roof footprint density
Cell Count & Technology 106 cells (Thin Film) Monofacial backsheet

How Many Applied Materials 1/2-P Size Single Junction Version 10 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Applied Materials 1/2-P Size Single Junction Version 10 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 29 6.0 kW 893 sq ft $1,502 $2,539
8 kW Class 39 8.07 kW 1,201 sq ft $2,020 $3,415
10 kW Class 49 10.14 kW 1,508 sq ft $2,538 $4,292

How Many Applied Materials 1/2-P Size Single Junction Version 10 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Applied Materials 1/2-P Size Single Junction Version 10 (108.32 V at 14 F).

Computed from Voc=97.1V and beta_Voc=-0.33%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 111.52 V 5 panels 557.6 V 8 panels
-10 C (14 F) 108.32 V 5 panels 541.6 V 9 panels
0 C (32 F) 105.11 V 5 panels 525.5 V 9 panels
25 C (77 F STC) 97.1 V 6 panels 582.6 V 10 panels

Which Cross-Brand Solar Modules Compare Closest to Applied Materials 1/2-P Size Single Junction Version 10?

Competing CEC solar panels closest to Applied Materials 1/2-P Size Single Junction Version 10 in nameplate wattage and Voc, starting with Grape Solar GS-S-220-CS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Grape Solar GS-S-220-CS
Grape Solar
220.0 W +13.0 W 59.4 V 12.94% 91.0%
Exeltech AM24-1-B-6-0-00
Exeltech
240.0 W +33.0 W 59.5 V 14.12% 88.3%
Grape Solar GS-S-240-CS
Grape Solar
240.0 W +33.0 W 59.3 V 14.12% 91.1%
Eoplly New Energy Technology EP125M/72-205W
Eoplly New Energy Technology
205.0 W -2.0 W 46.21 V 16.06% 89.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Applied Materials 1/2-P Size Single Junction Version 10?

Evaluate Applied Materials 1/2-P Size Single Junction Version 10 (207.0 W STC, 97.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Applied Materials 1/2-P Size Single Junction Version 10 reaches 111.52 V per panel—exceeding 5 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 39 panels for an 8 kW build require 1,201 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 39 panels (1,201 sq ft).
  • 2026 tax credit baseline: cash residential installs of Applied Materials 1/2-P Size Single Junction Version 10 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Applied Materials 1/2-P Size Single Junction Version 10 8 kW Residential Fit

Needs 39 modules (1,201 sq ft) with a 15 A string OCPD, offsetting ~$2,020/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 5 panels (-10 C) or 5 panels (-20 C), or compare Grape Solar GS-S-220-CS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 192.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Applied Materials 1/2-P Size Single Junction Version 10 by Applied Materials grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Applied Materials 1/2-P Size Single Junction Version 10?

Multiplying Applied Materials 1/2-P Size Single Junction Version 10's 2.9 A short-circuit current by 1.56 equals 4.52 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Applied Materials 1/2-P Size Single Junction Version 10 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 108.32 V cold Voc at 14 F and handles 2.9 A Isc; string inverters cap Applied Materials 1/2-P Size Single Junction Version 10 at 5 panels on 600 V.

Is Applied Materials 1/2-P Size Single Junction Version 10 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Applied Materials 1/2-P Size Single Junction Version 10 rely on utility bill offset (~$2,020/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.