Skip to main content
WireAndSun
Calculators
CEC PV Module

Applied Materials Full Size Tandem Junction — CEC Solar Module Specifications

Manufacturer: Applied Materials Registry: CEC Verified Engineering Specification

Applied Materials Full Size Tandem Junction is a 458.0 W STC (420.2 W PTC) Thin Film solar module ranking #5,416 of 21,677 CEC listings (top 25.0%; higher than 75.0% of peers). It delivers 8.01% efficiency, 280.0 V Voc at 25 C, and 319.3 V cold Voc at -10 C (1 panel max per 600 V string).

STC Wattage
458.0 W
PTC Wattage
420.2 W
Voc @ 25C
280.0 V
Efficiency
8.01%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Applied Materials Full Size Tandem Junction Compare Against Peer CEC Listings?

Solar engineering breakdown for Applied Materials Full Size Tandem Junction: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 458.0 W STC and 420.2 W PTC, Applied Materials Full Size Tandem Junction sits +73.0 W vs all-CEC median (top 25.0%; higher than 75.0% of peers) among 21,677 listed modules. Power density reaches 80.1 W/m2 (11.90 percentage points below 19.91% CEC median). Higher 280.0 V open-circuit voltage caps 600 V residential strings at 1 panel at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 3 panels in series. Alternative peer First Solar Inc FS-6460-P-B-2 rates 460.0 W.

Where Does Applied Materials Full Size Tandem Junction Fall Across Listed CEC Models?

Distribution marker showing Applied Materials Full Size Tandem Junction (458.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Applied Materials Full Size Tandem Junction (458.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCApplied Materials : 458.0 W

What Dataset Percentiles Define Applied Materials Full Size Tandem Junction?

Dataset percentiles tracking Applied Materials Full Size Tandem Junction power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Applied Materials Full Size Tandem Junction Engineering BenchmarksPercentile comparison of Applied Materials Full Size Tandem Junction wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage458.0 WPTC/STC Retention91.7%Module Efficiency8.01%

What Do the Dataset Ranks Show for Applied Materials Full Size Tandem Junction?

Benchmark highlights for Applied Materials Full Size Tandem Junction covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #5,416 / 21,677

Top 25.0% STC Output

458.0 W STC (+73.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #21,652

8.01% Aperture Efficiency

Power density 80.1 W/m2 (11.90 percentage points below 19.91% CEC median). PTC/STC ratio: 91.7% (rank #15,053).

NEC 690.7 Limit

1 Panel Max @ -10 C (600 V)

Cold Voc reaches 319.3 V at -10 C (319.3 V string) and 330.53 V at -20 C (1 max).

8 kW Reference Array

18 Panels = 8,244 W STC

Occupies 103.0 m2 (1,108 sq ft) producing 7,564 W PTC; NEC 690.8 OCPD floor is 4.06 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 280.0 * (1 + (-0.401/100) * (-10 - 25)) = 319.3 V | OCPD = 1.56 * 2.6 = 4.06 A

Inputs from CEC Modules.csv for Applied Materials Full Size Tandem Junction: Voc=280.0 V, beta_Voc=-0.401%/C, Isc=2.6 A, STC=458.0 W, Area=5.72 m2.

Result: 1 panel max on 600 V (319.3 V); 18 panels for 8 kW (1,108 sq ft).

What Are the Published CEC Specifications for Applied Materials Full Size Tandem Junction?

Official CEC datasheet figures for Applied Materials Full Size Tandem Junction (Thin Film) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Applied Materials Full Size Tandem Junction.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 458.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 420.2 W (91.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 280.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 2.6 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 216.0 V / 2.16 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.401 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 8.01% (5.72 m2) Array roof footprint density
Cell Count & Technology 216 cells (Thin Film) Monofacial backsheet

How Many Applied Materials Full Size Tandem Junction Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Applied Materials Full Size Tandem Junction modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.41 kW 862 sq ft $1,604 $2,713
8 kW Class 18 8.24 kW 1,108 sq ft $2,062 $3,487
10 kW Class 22 10.08 kW 1,355 sq ft $2,523 $4,266

How Many Applied Materials Full Size Tandem Junction Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Applied Materials Full Size Tandem Junction (319.3 V at 14 F).

Computed from Voc=280.0V and beta_Voc=-0.401%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 330.53 V 1 panel 330.5 V 3 panels
-10 C (14 F) 319.3 V 1 panel 319.3 V 3 panels
0 C (32 F) 308.07 V 1 panel 308.1 V 3 panels
25 C (77 F STC) 280.0 V 2 panels 560.0 V 3 panels

Which Cross-Brand Solar Modules Compare Closest to Applied Materials Full Size Tandem Junction?

Competing CEC solar panels closest to Applied Materials Full Size Tandem Junction in nameplate wattage and Voc, starting with First Solar Inc FS-6460-P-B-2.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
First Solar Inc FS-6460-P-B-2
First Solar Inc
460.0 W +2.0 W 229.31 V 18.25% 95.0%
First Solar Inc FS-6460A-P-B-2
First Solar Inc
460.0 W +2.0 W 229.31 V 18.25% 95.0%
First Solar Inc FS-6465-P-B-2
First Solar Inc
465.0 W +7.0 W 229.93 V 18.45% 95.0%
First Solar Inc FS-6465A-P-B-2
First Solar Inc
465.0 W +7.0 W 229.93 V 18.45% 95.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Applied Materials Full Size Tandem Junction?

Evaluate Applied Materials Full Size Tandem Junction (458.0 W STC, 280.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Applied Materials Full Size Tandem Junction reaches 330.53 V per panel—exceeding 1 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 1,108 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (1,108 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Applied Materials Full Size Tandem Junction carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Applied Materials Full Size Tandem Junction 8 kW Residential Fit

Needs 18 modules (1,108 sq ft) with a 15 A string OCPD, offsetting ~$2,062/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 1 panels (-10 C) or 1 panels (-20 C), or compare First Solar Inc FS-6460-P-B-2.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 420.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Applied Materials Full Size Tandem Junction by Applied Materials grounded in CEC test data and NEC 690.7/690.8 limits.

How many Applied Materials Full Size Tandem Junction panels fit on a 600 V winter solar string?

At -10 C (14 F), Applied Materials Full Size Tandem Junction cold Voc rises from 280.0 V to 319.3 V (beta_Voc -0.401%/C), capping a 600 V string at 1 panel (319.3 V).

How much roof area does an 8 kW array of Applied Materials Full Size Tandem Junction need?

An 8 kW DC system uses 18 Applied Materials Full Size Tandem Junction modules (8,244 W STC / 7,564 W PTC), covering roughly 1,108 sq ft and saving ~$2,062/yr at 18.54 c/kWh.

How does Applied Materials Full Size Tandem Junction compare against First Solar Inc FS-6460-P-B-2?

Applied Materials Full Size Tandem Junction outputs 458.0 W STC (280.0 V Voc, rank #5,416 of 21,677), while First Solar Inc FS-6460-P-B-2 delivers 460.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.