Applied Materials Full Size Tandem Junction is a 458.0 W STC (420.2 W PTC) Thin Film solar module ranking #5,416 of 21,677 CEC listings (top 25.0%; higher than 75.0% of peers). It delivers 8.01% efficiency, 280.0 V Voc at 25 C, and 319.3 V cold Voc at -10 C (1 panel max per 600 V string).
- STC Wattage
- 458.0 W
- PTC Wattage
- 420.2 W
- Voc @ 25C
- 280.0 V
- Efficiency
- 8.01%
How Does Applied Materials Full Size Tandem Junction Compare Against Peer CEC Listings?
Solar engineering breakdown for Applied Materials Full Size Tandem Junction: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 458.0 W STC and 420.2 W PTC, Applied Materials Full Size Tandem Junction sits +73.0 W vs all-CEC median (top 25.0%; higher than 75.0% of peers) among 21,677 listed modules. Power density reaches 80.1 W/m2 (11.90 percentage points below 19.91% CEC median). Higher 280.0 V open-circuit voltage caps 600 V residential strings at 1 panel at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 3 panels in series. Alternative peer First Solar Inc FS-6460-P-B-2 rates 460.0 W.
Where Does Applied Materials Full Size Tandem Junction Fall Across Listed CEC Models?
Distribution marker showing Applied Materials Full Size Tandem Junction (458.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Applied Materials Full Size Tandem Junction?
Dataset percentiles tracking Applied Materials Full Size Tandem Junction power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Applied Materials Full Size Tandem Junction?
Benchmark highlights for Applied Materials Full Size Tandem Junction covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 25.0% STC Output
458.0 W STC (+73.0 W vs all-CEC median) vs 117.5 W Thin Film median.
8.01% Aperture Efficiency
Power density 80.1 W/m2 (11.90 percentage points below 19.91% CEC median). PTC/STC ratio: 91.7% (rank #15,053).
1 Panel Max @ -10 C (600 V)
Cold Voc reaches 319.3 V at -10 C (319.3 V string) and 330.53 V at -20 C (1 max).
18 Panels = 8,244 W STC
Occupies 103.0 m2 (1,108 sq ft) producing 7,564 W PTC; NEC 690.8 OCPD floor is 4.06 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 280.0 * (1 + (-0.401/100) * (-10 - 25)) = 319.3 V | OCPD = 1.56 * 2.6 = 4.06 A
Inputs from CEC Modules.csv for Applied Materials Full Size Tandem Junction: Voc=280.0 V, beta_Voc=-0.401%/C, Isc=2.6 A, STC=458.0 W, Area=5.72 m2.
Result: 1 panel max on 600 V (319.3 V); 18 panels for 8 kW (1,108 sq ft).
What Are the Published CEC Specifications for Applied Materials Full Size Tandem Junction?
Official CEC datasheet figures for Applied Materials Full Size Tandem Junction (Thin Film) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 458.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 420.2 W (91.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 280.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 2.6 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 216.0 V / 2.16 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.401 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 8.01% (5.72 m2) | Array roof footprint density |
| Cell Count & Technology | 216 cells (Thin Film) | Monofacial backsheet |
How Many Applied Materials Full Size Tandem Junction Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Applied Materials Full Size Tandem Junction modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.41 kW | 862 sq ft | $1,604 | $2,713 |
| 8 kW Class | 18 | 8.24 kW | 1,108 sq ft | $2,062 | $3,487 |
| 10 kW Class | 22 | 10.08 kW | 1,355 sq ft | $2,523 | $4,266 |
How Many Applied Materials Full Size Tandem Junction Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Applied Materials Full Size Tandem Junction (319.3 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 330.53 V | 1 panel | 330.5 V | 3 panels |
| -10 C (14 F) | 319.3 V | 1 panel | 319.3 V | 3 panels |
| 0 C (32 F) | 308.07 V | 1 panel | 308.1 V | 3 panels |
| 25 C (77 F STC) | 280.0 V | 2 panels | 560.0 V | 3 panels |
Which Cross-Brand Solar Modules Compare Closest to Applied Materials Full Size Tandem Junction?
Competing CEC solar panels closest to Applied Materials Full Size Tandem Junction in nameplate wattage and Voc, starting with First Solar Inc FS-6460-P-B-2.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| First Solar Inc FS-6460-P-B-2 First Solar Inc |
460.0 W | +2.0 W | 229.31 V | 18.25% | 95.0% |
| First Solar Inc FS-6460A-P-B-2 First Solar Inc |
460.0 W | +2.0 W | 229.31 V | 18.25% | 95.0% |
| First Solar Inc FS-6465-P-B-2 First Solar Inc |
465.0 W | +7.0 W | 229.93 V | 18.45% | 95.0% |
| First Solar Inc FS-6465A-P-B-2 First Solar Inc |
465.0 W | +7.0 W | 229.93 V | 18.45% | 95.0% |
What Are the Design Limits and Best-Fit Uses for Applied Materials Full Size Tandem Junction?
Evaluate Applied Materials Full Size Tandem Junction (458.0 W STC, 280.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Applied Materials Full Size Tandem Junction reaches 330.53 V per panel—exceeding 1 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 1,108 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (1,108 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Applied Materials Full Size Tandem Junction carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Applied Materials Full Size Tandem Junction 8 kW Residential Fit
Needs 18 modules (1,108 sq ft) with a 15 A string OCPD, offsetting ~$2,062/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 1 panels (-10 C) or 1 panels (-20 C), or compare First Solar Inc FS-6460-P-B-2.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 420.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Applied Materials Full Size Tandem Junction by Applied Materials grounded in CEC test data and NEC 690.7/690.8 limits.
How many Applied Materials Full Size Tandem Junction panels fit on a 600 V winter solar string?
At -10 C (14 F), Applied Materials Full Size Tandem Junction cold Voc rises from 280.0 V to 319.3 V (beta_Voc -0.401%/C), capping a 600 V string at 1 panel (319.3 V).
How much roof area does an 8 kW array of Applied Materials Full Size Tandem Junction need?
An 8 kW DC system uses 18 Applied Materials Full Size Tandem Junction modules (8,244 W STC / 7,564 W PTC), covering roughly 1,108 sq ft and saving ~$2,062/yr at 18.54 c/kWh.
How does Applied Materials Full Size Tandem Junction compare against First Solar Inc FS-6460-P-B-2?
Applied Materials Full Size Tandem Junction outputs 458.0 W STC (280.0 V Voc, rank #5,416 of 21,677), while First Solar Inc FS-6460-P-B-2 delivers 460.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)