Skip to main content
WireAndSun
Calculators
CEC PV Module

Applied Materials 1/2-L Size Tandem Junction — CEC Solar Module Specifications

Manufacturer: Applied Materials Registry: CEC Verified Engineering Specification

Applied Materials 1/2-L Size Tandem Junction is a 229.0 W STC (210.1 W PTC) Thin Film solar module ranking #20,653 of 21,677 CEC listings (below all-CEC median; higher than 4.7% of peers). It delivers 8.01% efficiency, 280.0 V Voc at 25 C, and 319.3 V cold Voc at -10 C (1 panel max per 600 V string).

STC Wattage
229.0 W
PTC Wattage
210.1 W
Voc @ 25C
280.0 V
Efficiency
8.01%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Applied Materials 1/2-L Size Tandem Junction Compare Against Peer CEC Listings?

How Applied Materials Applied Materials 1/2-L Size Tandem Junction handles rooftop heat (210.1 W PTC), 8 kW sizing, and cold winter string voltage.

Applied Materials builds the Applied Materials 1/2-L Size Tandem Junction (Thin Film) as a compact residential or specialty off-grid module delivering 80.1 W/m2 (11.90 percentage points below 19.91% CEC median). Compared against Grape Solar GS-S-220-CS (220.0 W), this model holds strong 91.7% PTC-to-STC heat retention (#15,053 of 21,677). Higher 280.0 V open-circuit voltage caps 600 V residential strings at 1 panel at 14 F (-10 C), while NEC 690.8 sets a 2.03 A overcurrent floor served by a 15 A breaker.

Where Does Applied Materials 1/2-L Size Tandem Junction Fall Across Listed CEC Models?

Where Applied Materials 1/2-L Size Tandem Junction (229.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Applied Materials 1/2-L Size Tandem Junction (229.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCApplied Materials : 229.0 W

What Dataset Percentiles Define Applied Materials 1/2-L Size Tandem Junction?

Percentile placement of Applied Materials 1/2-L Size Tandem Junction across power density (80.1 W/m2), thermal retention, and nameplate STC wattage.

Applied Materials 1/2-L Size Tandem Junction Engineering BenchmarksPercentile comparison of Applied Materials 1/2-L Size Tandem Junction wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage229.0 WPTC/STC Retention91.7%Module Efficiency8.01%

What Do the Dataset Ranks Show for Applied Materials 1/2-L Size Tandem Junction?

Four critical engineering numbers homeowners and solar installers check first when reviewing Applied Materials 1/2-L Size Tandem Junction specifications.

Rank #20,653 / 21,677

229.0 W STC · Higher Than 4.7%

229.0 W STC (-156.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #21,652

8.01% Aperture Efficiency

Power density 80.1 W/m2 (11.90 percentage points below 19.91% CEC median). PTC/STC ratio: 91.7% (rank #15,053).

NEC 690.7 Limit

1 Panel Max @ -10 C (600 V)

Cold Voc reaches 319.3 V at -10 C (319.3 V string) and 330.53 V at -20 C (1 max).

8 kW Reference Array

35 Panels = 8,015 W STC

Occupies 100.1 m2 (1,077 sq ft) producing 7,354 W PTC; NEC 690.8 OCPD floor is 2.03 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 280.0 * (1 + (-0.401/100) * (-10 - 25)) = 319.3 V | OCPD = 1.56 * 1.3 = 2.03 A

Inputs from CEC Modules.csv for Applied Materials 1/2-L Size Tandem Junction: Voc=280.0 V, beta_Voc=-0.401%/C, Isc=1.3 A, STC=229.0 W, Area=2.86 m2.

Result: 1 panel max on 600 V (319.3 V); 35 panels for 8 kW (1,077 sq ft).

What Are the Published CEC Specifications for Applied Materials 1/2-L Size Tandem Junction?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Applied Materials 1/2-L Size Tandem Junction.

Official California Energy Commission (NREL SAM) test parameters for Applied Materials 1/2-L Size Tandem Junction.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 229.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 210.1 W (91.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 280.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 1.3 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 216.0 V / 1.08 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.401 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 8.01% (2.86 m2) Array roof footprint density
Cell Count & Technology 216 cells (Thin Film) Monofacial backsheet

How Many Applied Materials 1/2-L Size Tandem Junction Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Applied Materials 1/2-L Size Tandem Junction (229.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 27 6.18 kW 831 sq ft $1,547 $2,616
8 kW Class 35 8.02 kW 1,077 sq ft $2,007 $3,394
10 kW Class 44 10.08 kW 1,355 sq ft $2,523 $4,266

How Many Applied Materials 1/2-L Size Tandem Junction Modules Fit in a Cold-Weather String?

Maximum series module counts for Applied Materials 1/2-L Size Tandem Junction from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=280.0V and beta_Voc=-0.401%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 330.53 V 1 panel 330.5 V 3 panels
-10 C (14 F) 319.3 V 1 panel 319.3 V 3 panels
0 C (32 F) 308.07 V 1 panel 308.1 V 3 panels
25 C (77 F STC) 280.0 V 2 panels 560.0 V 3 panels

Which Cross-Brand Solar Modules Compare Closest to Applied Materials 1/2-L Size Tandem Junction?

Alternative CEC solar modules from competing brands near Applied Materials 1/2-L Size Tandem Junction (229.0 W), including Grape Solar GS-S-220-CS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Grape Solar GS-S-220-CS
Grape Solar
220.0 W -9.0 W 59.4 V 12.94% 91.0%
Exeltech AM24-1-B-6-0-00
Exeltech
240.0 W +11.0 W 59.5 V 14.12% 88.3%
Grape Solar GS-S-240-CS
Grape Solar
240.0 W +11.0 W 59.3 V 14.12% 91.1%
Eoplly New Energy Technology EP125M/72-205W
Eoplly New Energy Technology
205.0 W -24.0 W 46.21 V 16.06% 89.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Applied Materials 1/2-L Size Tandem Junction?

Evaluate Applied Materials 1/2-L Size Tandem Junction (229.0 W STC, 280.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Applied Materials 1/2-L Size Tandem Junction reaches 330.53 V per panel—exceeding 1 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 35 panels for an 8 kW build require 1,077 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (1,077 sq ft).
  • 2026 tax credit baseline: cash residential installs of Applied Materials 1/2-L Size Tandem Junction carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Applied Materials 1/2-L Size Tandem Junction 8 kW Residential Fit

Needs 35 modules (1,077 sq ft) with a 15 A string OCPD, offsetting ~$2,007/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 1 panels (-10 C) or 1 panels (-20 C), or compare Grape Solar GS-S-220-CS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 210.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Applied Materials 1/2-L Size Tandem Junction by Applied Materials grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Applied Materials 1/2-L Size Tandem Junction?

Multiplying Applied Materials 1/2-L Size Tandem Junction's 1.3 A short-circuit current by 1.56 equals 2.03 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Applied Materials 1/2-L Size Tandem Junction pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 319.3 V cold Voc at 14 F and handles 1.3 A Isc; string inverters cap Applied Materials 1/2-L Size Tandem Junction at 1 panels on 600 V.

Is Applied Materials 1/2-L Size Tandem Junction eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Applied Materials 1/2-L Size Tandem Junction rely on utility bill offset (~$2,007/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.