Manufacturer: Grape Solar Registry: CEC Verified Engineering Specification

Grape Solar GS-S-240-CS is a 240.0 W STC (218.7 W PTC) Mono-c-Si solar module ranking #20,160 of 21,677 CEC listings (below all-CEC median; higher than 6.1% of peers). It delivers 14.12% efficiency, 59.3 V Voc at 25 C, and 67.06 V cold Voc at -10 C (8 panels max per 600 V string).

STC Wattage
240.0 W
PTC Wattage
218.7 W
Voc @ 25C
59.3 V
Efficiency
14.12%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Grape Solar GS-S-240-CS Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Grape Solar GS-S-240-CS (Mono-c-Si) residential solar systems.

Homeowners evaluating Grape Solar GS-S-240-CS need 25 panels for 6 kW or 34 panels (622 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (622 sq ft). Under NEC 690.7(A), beta_Voc (-0.374%/C) pushes open-circuit voltage to 67.06 V at 14 F and 69.28 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Grape Solar GS-S-240-CS Fall Across Listed CEC Models?

Comparison of Grape Solar GS-S-240-CS (240.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Grape Solar GS-S-240-CS (240.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCGrape Solar GS-S-2: 240.0 W

What Dataset Percentiles Define Grape Solar GS-S-240-CS?

Relative ranking of Grape Solar GS-S-240-CS across nameplate watts, 91.1% PTC thermal ratio, and module aperture efficiency. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Grape Solar GS-S-240-CS Engineering BenchmarksPercentile comparison of Grape Solar GS-S-240-CS wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage240.0 WPTC/STC Retention91.1%Module Efficiency14.12%

What Do the Dataset Ranks Show for Grape Solar GS-S-240-CS?

Summary of Grape Solar GS-S-240-CS output rank, 8 kW array size (34 panels), efficiency rating, and 600 V string limit.

Rank #20,160 / 21,677

240.0 W STC · Higher Than 6.1%

240.0 W STC (-145.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #20,797

14.12% Aperture Efficiency

Power density 141.2 W/m2 (5.79 percentage points below 19.91% CEC median). PTC/STC ratio: 91.1% (rank #16,462).

NEC 690.7 Limit

8 Panels Max @ -10 C (600 V)

Cold Voc reaches 67.06 V at -10 C (536.5 V string) and 69.28 V at -20 C (8 max).

8 kW Reference Array

34 Panels = 8,160 W STC

Occupies 57.8 m2 (622 sq ft) producing 7,436 W PTC; NEC 690.8 OCPD floor is 8.42 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 59.3 * (1 + (-0.374/100) * (-10 - 25)) = 67.06 V | OCPD = 1.56 * 5.4 = 8.42 A

Inputs from CEC Modules.csv for Grape Solar GS-S-240-CS: Voc=59.3 V, beta_Voc=-0.374%/C, Isc=5.4 A, STC=240.0 W, Area=1.7 m2.

Result: 8 panels max on 600 V (536.5 V); 34 panels for 8 kW (622 sq ft).

What Are the Published CEC Specifications for Grape Solar GS-S-240-CS?

Complete CEC test sheet for Grape Solar GS-S-240-CS including Isc (5.4 A), Voc (59.3 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Grape Solar GS-S-240-CS.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 240.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 218.7 W (91.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 59.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 5.4 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 48.8 V / 4.99 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.374 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.12% (1.7 m2) Array roof footprint density
Cell Count & Technology 96 cells (Mono-c-Si) Monofacial backsheet

How Many Grape Solar GS-S-240-CS Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Grape Solar GS-S-240-CS.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 25 6.0 kW 457 sq ft $1,502 $2,539
8 kW Class 34 8.16 kW 622 sq ft $2,042 $3,454
10 kW Class 42 10.08 kW 769 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This Grape Solar Series?

Related Grape Solar power steps and black/silver trims consolidated into this Grape Solar GS-S-240-CS series guide. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sibling CEC listings grouped into the Grape Solar GS-S-240-CS wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Grape Solar GS-S-230-CS 230.0 W 209.4 W 58.8 V 47.5 V 13.53%
Grape Solar GS-S-240-CS 240.0 W 218.7 W 59.3 V 48.8 V 14.12%

How Many Grape Solar GS-S-240-CS Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Grape Solar GS-S-240-CS (59.3 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=59.3V and beta_Voc=-0.374%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 69.28 V 8 panels 554.2 V 14 panels
-10 C (14 F) 67.06 V 8 panels 536.5 V 14 panels
0 C (32 F) 64.84 V 9 panels 583.6 V 15 panels
25 C (77 F STC) 59.3 V 10 panels 593.0 V 16 panels

Which Cross-Brand Solar Modules Compare Closest to Grape Solar GS-S-240-CS?

Four comparable CEC modules such as Exeltech AM24-1-B-6-0-00 (240.0 W) for side-by-side solar quote checks. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Exeltech AM24-1-B-6-0-00
Exeltech
240.0 W Tie (0 W) 59.5 V 14.12% 88.3%
Gintung Energy ASEC-245G6M
Gintung Energy
245.0 W +5.0 W 43.39 V 12.53% 89.1%
Changzhou Nesl Solartech DJ-240P-ST15
Changzhou Nesl Solartech
240.0 W Tie (0 W) 39.64 V 12.39% 89.8%
Hansol Technics Co Ltd HS240ME-V01
Hansol Technics Co Ltd
240.0 W Tie (0 W) 37.7 V 14.99% 89.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Grape Solar GS-S-240-CS?

Evaluate Grape Solar GS-S-240-CS (240.0 W STC, 59.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Grape Solar GS-S-240-CS reaches 69.28 V per panel—exceeding 8 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 34 panels for an 8 kW build require 622 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (622 sq ft).
  • 2026 tax credit baseline: cash residential installs of Grape Solar GS-S-240-CS carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Grape Solar GS-S-240-CS 8 kW Residential Fit

Needs 34 modules (622 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 8 panels (-10 C) or 8 panels (-20 C), or compare Exeltech AM24-1-B-6-0-00.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 218.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Grape Solar GS-S-240-CS by Grape Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Grape Solar GS-S-240-CS PTC wattage (218.7 W) lower than STC (240.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 218.7 W PTC (91.1% retention) across Grape Solar GS-S-240-CS's 1.7 m2 aperture.

Who should skip Grape Solar GS-S-240-CS on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 34 Grape Solar GS-S-240-CS panels (622 sq ft) leave unusable roof gaps vs. Exeltech AM24-1-B-6-0-00.

What is the 1,000 V commercial string limit for Grape Solar GS-S-240-CS?

On 1,000 V commercial inverters at -10 C (67.06 V cold Voc), Grape Solar GS-S-240-CS fits up to 14 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Grape Solar GS-S-240-CS.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.