Exeltech AM24-1-B-6-0-00 is a 240.0 W STC (211.9 W PTC) Multi-c-Si solar module ranking #20,160 of 21,677 CEC listings (below all-CEC median; higher than 6.1% of peers). It delivers 14.12% efficiency, 59.5 V Voc at 25 C, and 66.98 V cold Voc at -10 C (8 panels max per 600 V string).
- STC Wattage
- 240.0 W
- PTC Wattage
- 211.9 W
- Voc @ 25C
- 59.5 V
- Efficiency
- 14.12%
How Does Exeltech AM24-1-B-6-0-00 Compare Against Peer CEC Listings?
How Exeltech Exeltech AM24-1-B-6-0-00 handles rooftop heat (211.9 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Exeltech AM24-1-B-6-0-00 exhibits 5.28 A short-circuit current, requiring a 8.24 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #20,160 of 21,677 (38.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 57.8 m2 for an 8 kW system (42 panels for 10 kW). Higher 59.5 V open-circuit voltage caps 600 V residential strings at 8 panels at 14 F (-10 C).
Where Does Exeltech AM24-1-B-6-0-00 Fall Across Listed CEC Models?
Where Exeltech AM24-1-B-6-0-00 (240.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Exeltech AM24-1-B-6-0-00?
Percentile placement of Exeltech AM24-1-B-6-0-00 across power density (141.2 W/m2), thermal retention, and nameplate STC wattage. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What Do the Dataset Ranks Show for Exeltech AM24-1-B-6-0-00?
Four critical engineering numbers homeowners and solar installers check first when reviewing Exeltech AM24-1-B-6-0-00 specifications. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
240.0 W STC · Higher Than 6.1%
240.0 W STC (-145.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
14.12% Aperture Efficiency
Power density 141.2 W/m2 (5.79 percentage points below 19.91% CEC median). PTC/STC ratio: 88.3% (rank #21,245).
8 Panels Max @ -10 C (600 V)
Cold Voc reaches 66.98 V at -10 C (535.8 V string) and 69.11 V at -20 C (8 max).
34 Panels = 8,160 W STC
Occupies 57.8 m2 (622 sq ft) producing 7,205 W PTC; NEC 690.8 OCPD floor is 8.24 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 59.5 * (1 + (-0.359/100) * (-10 - 25)) = 66.98 V | OCPD = 1.56 * 5.28 = 8.24 A
Inputs from CEC Modules.csv for Exeltech AM24-1-B-6-0-00: Voc=59.5 V, beta_Voc=-0.359%/C, Isc=5.28 A, STC=240.0 W, Area=1.7 m2.
Result: 8 panels max on 600 V (535.8 V); 34 panels for 8 kW (622 sq ft).
What Are the Published CEC Specifications for Exeltech AM24-1-B-6-0-00?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Exeltech AM24-1-B-6-0-00. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 240.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 211.9 W (88.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 59.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 5.28 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 48.6 V / 4.95 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.359 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.12% (1.7 m2) | Array roof footprint density |
| Cell Count & Technology | 96 cells (Multi-c-Si) | Monofacial backsheet |
How Many Exeltech AM24-1-B-6-0-00 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Exeltech AM24-1-B-6-0-00 (240.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 25 | 6.0 kW | 457 sq ft | $1,502 | $2,539 |
| 8 kW Class | 34 | 8.16 kW | 622 sq ft | $2,042 | $3,454 |
| 10 kW Class | 42 | 10.08 kW | 769 sq ft | $2,523 | $4,266 |
How Many Exeltech AM24-1-B-6-0-00 Modules Fit in a Cold-Weather String?
Maximum series module counts for Exeltech AM24-1-B-6-0-00 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 69.11 V | 8 panels | 552.9 V | 14 panels |
| -10 C (14 F) | 66.98 V | 8 panels | 535.8 V | 14 panels |
| 0 C (32 F) | 64.84 V | 9 panels | 583.6 V | 15 panels |
| 25 C (77 F STC) | 59.5 V | 10 panels | 595.0 V | 16 panels |
Which Cross-Brand Solar Modules Compare Closest to Exeltech AM24-1-B-6-0-00?
Alternative CEC solar modules from competing brands near Exeltech AM24-1-B-6-0-00 (240.0 W), including Grape Solar GS-S-240-CS. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Grape Solar GS-S-240-CS Grape Solar |
240.0 W | Tie (0 W) | 59.3 V | 14.12% | 91.1% |
| Grape Solar GS-S-220-CS Grape Solar |
220.0 W | -20.0 W | 59.4 V | 12.94% | 91.0% |
| Gintung Energy ASEC-245G6M Gintung Energy |
245.0 W | +5.0 W | 43.39 V | 12.53% | 89.1% |
| Changzhou Nesl Solartech DJ-240P-ST15 Changzhou Nesl Solartech |
240.0 W | Tie (0 W) | 39.64 V | 12.39% | 89.8% |
What Are the Design Limits and Best-Fit Uses for Exeltech AM24-1-B-6-0-00?
Evaluate Exeltech AM24-1-B-6-0-00 (240.0 W STC, 59.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Exeltech AM24-1-B-6-0-00 reaches 69.11 V per panel—exceeding 8 panels in series voids 600 V inverter warranties.
- Footprint constraint: 34 panels for an 8 kW build require 622 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (622 sq ft).
- 2026 tax credit baseline: cash residential installs of Exeltech AM24-1-B-6-0-00 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Exeltech AM24-1-B-6-0-00 8 kW Residential Fit
Needs 34 modules (622 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 8 panels (-10 C) or 8 panels (-20 C), or compare Grape Solar GS-S-240-CS.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 211.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Exeltech AM24-1-B-6-0-00 by Exeltech grounded in CEC test data and NEC 690.7/690.8 limits. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
Why is Exeltech AM24-1-B-6-0-00 PTC wattage (211.9 W) lower than STC (240.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 211.9 W PTC (88.3% retention) across Exeltech AM24-1-B-6-0-00's 1.7 m2 aperture.
Who should skip Exeltech AM24-1-B-6-0-00 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 34 Exeltech AM24-1-B-6-0-00 panels (622 sq ft) leave unusable roof gaps vs. Grape Solar GS-S-240-CS.
What is the 1,000 V commercial string limit for Exeltech AM24-1-B-6-0-00?
On 1,000 V commercial inverters at -10 C (66.98 V cold Voc), Exeltech AM24-1-B-6-0-00 fits up to 14 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Exeltech AM24-1-B-6-0-00.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)