Auxin Solar AXNG1M410W is a 410.0 W STC (382.5 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 20.92% efficiency, 49.47 V Voc at 25 C, and 54.04 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 410.0 W
- PTC Wattage
- 382.5 W
- Voc @ 25C
- 49.47 V
- Efficiency
- 20.92%
How Does Auxin Solar AXNG1M410W Compare Against Peer CEC Listings?
Engineering position of Auxin Solar AXNG1M410W (410.0 W STC) vs. Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W across 5,889 CEC Mono-c-Si solar modules.
Ranking #8,539 across 21,677 CEC solar panels (top 41.3%; higher than 58.7% of peers), Auxin Solar AXNG1M410W operates as a modern high-density residential and light-commercial module sitting equal to the 410.0 W Mono-c-Si median. Higher 49.47 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C). With strong 93.3% PTC-to-STC heat retention (#8,323 of 21,677), 20 panels occupy 422 sq ft and offset roughly $2,052/yr at average US rates (or $3,470/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Auxin Solar AXNG1M410W Fall Across Listed CEC Models?
Plots Auxin Solar AXNG1M410W at 410.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Auxin Solar AXNG1M410W?
Benchmarks Auxin Solar AXNG1M410W on STC wattage, thermal PTC/STC retention, and 20.92 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Auxin Solar AXNG1M410W?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Auxin Solar AXNG1M410W by Auxin Solar.
Top 41.3% STC Output
410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.92% Aperture Efficiency
Power density 209.2 W/m2 (1.01 percentage points above 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.04 V at -10 C (594.4 V string) and 55.35 V at -20 C (10 max).
20 Panels = 8,200 W STC
Occupies 39.2 m2 (422 sq ft) producing 7,650 W PTC; NEC 690.8 OCPD floor is 16.1 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.47 * (1 + (-0.264/100) * (-10 - 25)) = 54.04 V | OCPD = 1.56 * 10.32 = 16.1 A
Inputs from CEC Modules.csv for Auxin Solar AXNG1M410W: Voc=49.47 V, beta_Voc=-0.264%/C, Isc=10.32 A, STC=410.0 W, Area=1.96 m2.
Result: 11 panels max on 600 V (594.4 V); 20 panels for 8 kW (422 sq ft).
What Are the Published CEC Specifications for Auxin Solar AXNG1M410W?
Laboratory test ratings recorded for Auxin Solar AXNG1M410W (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 382.5 W (93.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.47 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.32 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 42.27 V / 9.7 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.264 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.92% (1.96 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Auxin Solar AXNG1M410W Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (422 sq ft at 8 kW), and estimated Year-1 electric bill offset for Auxin Solar AXNG1M410W.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.15 kW | 316 sq ft | $1,539 | $2,603 |
| 8 kW Class | 20 | 8.2 kW | 422 sq ft | $2,052 | $3,470 |
| 10 kW Class | 25 | 10.25 kW | 527 sq ft | $2,565 | $4,338 |
Which Sibling Wattage & Trim Variants Belong to This Auxin Solar Series?
Sibling wattage bins and frame colors grouped with Auxin Solar AXNG1M410W under Auxin Solar to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Auxin Solar AXNG1M400W | 400.0 W | 372.9 W | 48.76 V | 41.56 V | 20.41% |
| Auxin Solar AXNG1M405W | 405.0 W | 377.7 W | 49.04 V | 41.84 V | 20.66% |
| Auxin Solar AXNG1M410W | 410.0 W | 382.5 W | 49.47 V | 42.27 V | 20.92% |
| Auxin Solar AXNG1M415W | 415.0 W | 387.3 W | 49.9 V | 42.7 V | 21.17% |
| Auxin Solar AXNG1M420W | 420.0 W | 392.1 W | 50.18 V | 42.98 V | 21.43% |
How Many Auxin Solar AXNG1M410W Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Auxin Solar AXNG1M410W (beta_Voc -0.264%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.35 V | 10 panels | 553.5 V | 18 panels |
| -10 C (14 F) | 54.04 V | 11 panels | 594.4 V | 18 panels |
| 0 C (32 F) | 52.74 V | 11 panels | 580.1 V | 18 panels |
| 25 C (77 F STC) | 49.47 V | 12 panels | 593.6 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Auxin Solar AXNG1M410W?
Closest cross-brand CEC competitors to Auxin Solar AXNG1M410W matched near 410.0 W STC and 49.47 V Voc, led by Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W Dehui Solar Power (Vietnam) CoLtd |
410.0 W | Tie (0 W) | 49.4 V | 21.47% | 92.6% |
| AXITEC AC-410MB/144V AXITEC |
410.0 W | Tie (0 W) | 49.3 V | 21.03% | 93.0% |
| BYD Company Limited BYD400MIK-36 BYD Company Limited |
410.0 W | Tie (0 W) | 49.21 V | 20.4% | 94.0% |
| AXITEC AC-410MH/144V AXITEC |
410.0 W | Tie (0 W) | 48.91 V | 20.71% | 93.5% |
What Are the Design Limits and Best-Fit Uses for Auxin Solar AXNG1M410W?
Evaluate Auxin Solar AXNG1M410W (410.0 W STC, 49.47 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Auxin Solar AXNG1M410W reaches 55.35 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 422 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (422 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Auxin Solar AXNG1M410W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Auxin Solar AXNG1M410W 8 kW Residential Fit
Needs 20 modules (422 sq ft) with a 20 A string OCPD, offsetting ~$2,052/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 382.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Auxin Solar AXNG1M410W by Auxin Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many Auxin Solar AXNG1M410W panels fit on a 600 V winter solar string?
At -10 C (14 F), Auxin Solar AXNG1M410W cold Voc rises from 49.47 V to 54.04 V (beta_Voc -0.264%/C), capping a 600 V string at 11 panels (594.4 V).
How much roof area does an 8 kW array of Auxin Solar AXNG1M410W need?
An 8 kW DC system uses 20 Auxin Solar AXNG1M410W modules (8,200 W STC / 7,650 W PTC), covering roughly 422 sq ft and saving ~$2,052/yr at 18.54 c/kWh.
How does Auxin Solar AXNG1M410W compare against Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W?
Auxin Solar AXNG1M410W outputs 410.0 W STC (49.47 V Voc, rank #8,539 of 21,677), while Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W delivers 410.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)