AXITEC AC-410MH/144V is a 410.0 W STC (383.4 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 20.71% efficiency, 48.91 V Voc at 25 C, and 53.48 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 410.0 W
- PTC Wattage
- 383.4 W
- Voc @ 25C
- 48.91 V
- Efficiency
- 20.71%
How Does AXITEC AC-410MH/144V Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for AXITEC AC-410MH/144V (Mono-c-Si) residential solar systems.
Homeowners evaluating AXITEC AC-410MH/144V need 15 panels for 6 kW or 20 panels (426 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 20 panels (426 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.267%/C) pushes open-circuit voltage to 53.48 V at 14 F and 54.79 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does AXITEC AC-410MH/144V Fall Across Listed CEC Models?
Comparison of AXITEC AC-410MH/144V (410.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What Dataset Percentiles Define AXITEC AC-410MH/144V?
Relative ranking of AXITEC AC-410MH/144V across nameplate watts, 93.5% PTC thermal ratio, and module aperture efficiency. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
What Do the Dataset Ranks Show for AXITEC AC-410MH/144V?
Summary of AXITEC AC-410MH/144V output rank, 8 kW array size (20 panels), efficiency rating, and 600 V string limit.
Top 41.3% STC Output
410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.71% Aperture Efficiency
Power density 207.1 W/m2 (0.80 percentage points above 19.91% CEC median). PTC/STC ratio: 93.5% (rank #7,159).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.48 V at -10 C (588.3 V string) and 54.79 V at -20 C (10 max).
20 Panels = 8,200 W STC
Occupies 39.6 m2 (426 sq ft) producing 7,668 W PTC; NEC 690.8 OCPD floor is 16.83 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.91 * (1 + (-0.267/100) * (-10 - 25)) = 53.48 V | OCPD = 1.56 * 10.79 = 16.83 A
Inputs from CEC Modules.csv for AXITEC AC-410MH/144V: Voc=48.91 V, beta_Voc=-0.267%/C, Isc=10.79 A, STC=410.0 W, Area=1.98 m2.
Result: 11 panels max on 600 V (588.3 V); 20 panels for 8 kW (426 sq ft).
What Are the Published CEC Specifications for AXITEC AC-410MH/144V?
Complete CEC test sheet for AXITEC AC-410MH/144V including Isc (10.79 A), Voc (48.91 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 383.4 W (93.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.91 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.79 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.12 V / 9.97 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.267 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.71% (1.98 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many AXITEC AC-410MH/144V Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using AXITEC AC-410MH/144V.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.15 kW | 320 sq ft | $1,539 | $2,603 |
| 8 kW Class | 20 | 8.2 kW | 426 sq ft | $2,052 | $3,470 |
| 10 kW Class | 25 | 10.25 kW | 533 sq ft | $2,565 | $4,338 |
Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?
Related AXITEC power steps and black/silver trims consolidated into this AXITEC AC-410MH/144V series guide. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| AXITEC AC-400MH/144V | 400.0 W | 373.8 W | 48.55 V | 40.77 V | 20.2% |
| AXITEC AC-405MH/144V | 405.0 W | 378.6 W | 48.73 V | 40.95 V | 20.45% |
| AXITEC AC-410MH/144V | 410.0 W | 383.4 W | 48.91 V | 41.12 V | 20.71% |
| AXITEC AC-415MH/144V | 415.0 W | 384.5 W | 49.6 V | 40.9 V | 21.73% |
| AXITEC AC-420MH/144V | 420.0 W | 389.3 W | 49.7 V | 41.0 V | 21.99% |
How Many AXITEC AC-410MH/144V Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for AXITEC AC-410MH/144V (48.91 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.79 V | 10 panels | 547.9 V | 18 panels |
| -10 C (14 F) | 53.48 V | 11 panels | 588.3 V | 18 panels |
| 0 C (32 F) | 52.17 V | 11 panels | 573.9 V | 19 panels |
| 25 C (77 F STC) | 48.91 V | 12 panels | 586.9 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-410MH/144V?
Four comparable CEC modules such as BYD Company Limited BYD400MIK-36 (410.0 W) for side-by-side solar quote checks. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| BYD Company Limited BYD400MIK-36 BYD Company Limited |
410.0 W | Tie (0 W) | 49.21 V | 20.4% | 94.0% |
| Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W Dehui Solar Power (Vietnam) CoLtd |
410.0 W | Tie (0 W) | 49.4 V | 21.47% | 92.6% |
| Auxin Solar AXNG1M410B Auxin Solar |
410.0 W | Tie (0 W) | 49.47 V | 20.92% | 93.4% |
| Auxin Solar AXNG1M410W Auxin Solar |
410.0 W | Tie (0 W) | 49.47 V | 20.92% | 93.3% |
What Are the Design Limits and Best-Fit Uses for AXITEC AC-410MH/144V?
Evaluate AXITEC AC-410MH/144V (410.0 W STC, 48.91 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-410MH/144V reaches 54.79 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 426 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (426 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of AXITEC AC-410MH/144V carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
AXITEC AC-410MH/144V 8 kW Residential Fit
Needs 20 modules (426 sq ft) with a 20 A string OCPD, offsetting ~$2,052/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare BYD Company Limited BYD400MIK-36.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 383.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for AXITEC AC-410MH/144V by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.
Why is AXITEC AC-410MH/144V PTC wattage (383.4 W) lower than STC (410.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 383.4 W PTC (93.5% retention) across AXITEC AC-410MH/144V's 1.98 m2 aperture.
Who should skip AXITEC AC-410MH/144V on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 AXITEC AC-410MH/144V panels (426 sq ft) leave unusable roof gaps vs. BYD Company Limited BYD400MIK-36.
What is the 1,000 V commercial string limit for AXITEC AC-410MH/144V?
On 1,000 V commercial inverters at -10 C (53.48 V cold Voc), AXITEC AC-410MH/144V fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting AXITEC AC-410MH/144V.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)