First Solar Inc FS-4105A is a 105.0 W STC (99.3 W PTC) Thin Film solar module ranking #21,543 of 21,677 CEC listings (below all-CEC median; higher than 0.6% of peers). It delivers 14.58% efficiency, 88.2 V Voc at 25 C, and 96.32 V cold Voc at -10 C (6 panels max per 600 V string).
- STC Wattage
- 105.0 W
- PTC Wattage
- 99.3 W
- Voc @ 25C
- 88.2 V
- Efficiency
- 14.58%
How Does First Solar Inc FS-4105A Compare Against Peer CEC Listings?
Solar engineering breakdown for First Solar Inc FS-4105A: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 105.0 W STC and 99.3 W PTC, First Solar Inc FS-4105A sits -280.0 W vs all-CEC median (below all-CEC median; higher than 0.6% of peers) among 21,677 listed modules. Power density reaches 145.8 W/m2 (5.33 percentage points below 19.91% CEC median). Higher 88.2 V open-circuit voltage caps 600 V residential strings at 6 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 10 panels in series. Alternative peer Caterpillar Inc PVT112 rates 112.5 W.
Where Does First Solar Inc FS-4105A Fall Across Listed CEC Models?
Distribution marker showing First Solar Inc FS-4105A (105.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define First Solar Inc FS-4105A?
Dataset percentiles tracking First Solar Inc FS-4105A power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for First Solar Inc FS-4105A?
Benchmark highlights for First Solar Inc FS-4105A covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
105.0 W STC · Higher Than 0.6%
105.0 W STC (-280.0 W vs all-CEC median) vs 117.5 W Thin Film median.
14.58% Aperture Efficiency
Power density 145.8 W/m2 (5.33 percentage points below 19.91% CEC median). PTC/STC ratio: 94.6% (rank #2,348).
6 Panels Max @ -10 C (600 V)
Cold Voc reaches 96.32 V at -10 C (577.9 V string) and 98.64 V at -20 C (6 max).
77 Panels = 8,085 W STC
Occupies 55.4 m2 (597 sq ft) producing 7,646 W PTC; NEC 690.8 OCPD floor is 2.46 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 88.2 * (1 + (-0.263/100) * (-10 - 25)) = 96.32 V | OCPD = 1.56 * 1.58 = 2.46 A
Inputs from CEC Modules.csv for First Solar Inc FS-4105A: Voc=88.2 V, beta_Voc=-0.263%/C, Isc=1.58 A, STC=105.0 W, Area=0.72 m2.
Result: 6 panels max on 600 V (577.9 V); 77 panels for 8 kW (597 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-4105A?
Official CEC datasheet figures for First Solar Inc FS-4105A (Thin Film) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 105.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 99.3 W (94.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 88.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 1.58 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 70.4 V / 1.49 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.263 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.58% (0.72 m2) | Array roof footprint density |
| Cell Count & Technology | 216 cells (Thin Film) | Monofacial backsheet |
How Many First Solar Inc FS-4105A Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many First Solar Inc FS-4105A modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 58 | 6.09 kW | 450 sq ft | $1,524 | $2,577 |
| 8 kW Class | 77 | 8.09 kW | 597 sq ft | $2,025 | $3,424 |
| 10 kW Class | 96 | 10.08 kW | 744 sq ft | $2,523 | $4,266 |
How Many First Solar Inc FS-4105A Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on First Solar Inc FS-4105A (96.32 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 98.64 V | 6 panels | 591.8 V | 10 panels |
| -10 C (14 F) | 96.32 V | 6 panels | 577.9 V | 10 panels |
| 0 C (32 F) | 94.0 V | 6 panels | 564.0 V | 10 panels |
| 25 C (77 F STC) | 88.2 V | 6 panels | 529.2 V | 11 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-4105A?
Competing CEC solar panels closest to First Solar Inc FS-4105A in nameplate wattage and Voc, starting with Caterpillar Inc PVT112.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Caterpillar Inc PVT112 Caterpillar Inc |
112.5 W | +7.5 W | 87.7 V | 15.62% | 92.9% |
| Caterpillar Inc PVT112 ARC Caterpillar Inc |
112.5 W | +7.5 W | 87.7 V | 15.62% | 92.9% |
| Toledo Solar Inc TS1 Toledo Solar Inc |
115.0 W | +10.0 W | 87.1 V | 15.97% | 92.9% |
| T-Solar Global TS102 T-Solar Global |
102.5 W | -2.5 W | 93.0 V | 7.19% | 93.0% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-4105A?
Evaluate First Solar Inc FS-4105A (105.0 W STC, 88.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-4105A reaches 98.64 V per panel—exceeding 6 panels in series voids 600 V inverter warranties.
- Footprint constraint: 77 panels for an 8 kW build require 597 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 77 panels (597 sq ft).
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-4105A carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-4105A 8 kW Residential Fit
Needs 77 modules (597 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 6 panels (-10 C) or 6 panels (-20 C), or compare Caterpillar Inc PVT112.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 99.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-4105A by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
How many First Solar Inc FS-4105A panels fit on a 600 V winter solar string?
At -10 C (14 F), First Solar Inc FS-4105A cold Voc rises from 88.2 V to 96.32 V (beta_Voc -0.263%/C), capping a 600 V string at 6 panels (577.9 V).
How much roof area does an 8 kW array of First Solar Inc FS-4105A need?
An 8 kW DC system uses 77 First Solar Inc FS-4105A modules (8,085 W STC / 7,646 W PTC), covering roughly 597 sq ft and saving ~$2,025/yr at 18.54 c/kWh.
How does First Solar Inc FS-4105A compare against Caterpillar Inc PVT112?
First Solar Inc FS-4105A outputs 105.0 W STC (88.2 V Voc, rank #21,543 of 21,677), while Caterpillar Inc PVT112 delivers 112.5 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)