Caterpillar Inc PVT112 ARC — CEC Solar Module Specifications

Manufacturer: Caterpillar Inc Registry: CEC Verified Engineering Specification

Caterpillar Inc PVT112 ARC is a 112.5 W STC (104.5 W PTC) Thin Film solar module ranking #21,521 of 21,677 CEC listings (below all-CEC median; higher than 0.7% of peers). It delivers 15.62% efficiency, 87.7 V Voc at 25 C, and 95.93 V cold Voc at -10 C (6 panels max per 600 V string).

STC Wattage
112.5 W
PTC Wattage
104.5 W
Voc @ 25C
87.7 V
Efficiency
15.62%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Caterpillar Inc PVT112 ARC Compare Against Peer CEC Listings?

Engineering position of Caterpillar Inc PVT112 ARC (112.5 W STC) vs. First Solar Inc FS-4112-2 across 106 CEC Thin Film solar modules.

Ranking #21,521 across 21,677 CEC solar panels (below all-CEC median; higher than 0.7% of peers), Caterpillar Inc PVT112 ARC operates as a compact residential or specialty off-grid module sitting 5.0 W below the 117.5 W Thin Film median. Higher 87.7 V open-circuit voltage caps 600 V residential strings at 6 panels at 14 F (-10 C). With strong 92.9% PTC-to-STC heat retention (#10,348 of 21,677), 72 panels occupy 558 sq ft and offset roughly $2,027/yr at average US rates (or $3,428/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Caterpillar Inc PVT112 ARC Fall Across Listed CEC Models?

Plots Caterpillar Inc PVT112 ARC at 112.5 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Caterpillar Inc PVT112 ARC (112.5 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCaterpillar Inc PV: 112.5 W

What Dataset Percentiles Define Caterpillar Inc PVT112 ARC?

Benchmarks Caterpillar Inc PVT112 ARC on STC wattage, thermal PTC/STC retention, and 15.62 aperture conversion efficiency against CEC peers.

Caterpillar Inc PVT112 ARC Engineering BenchmarksPercentile comparison of Caterpillar Inc PVT112 ARC wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage112.5 WPTC/STC Retention92.9%Module Efficiency15.62%

What Do the Dataset Ranks Show for Caterpillar Inc PVT112 ARC?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Caterpillar Inc PVT112 ARC by Caterpillar Inc.

Rank #21,521 / 21,677

112.5 W STC · Higher Than 0.7%

112.5 W STC (-272.5 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #18,755

15.62% Aperture Efficiency

Power density 156.2 W/m2 (4.29 percentage points below 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).

NEC 690.7 Limit

6 Panels Max @ -10 C (600 V)

Cold Voc reaches 95.93 V at -10 C (575.6 V string) and 98.28 V at -20 C (6 max).

8 kW Reference Array

72 Panels = 8,100 W STC

Occupies 51.8 m2 (558 sq ft) producing 7,524 W PTC; NEC 690.8 OCPD floor is 2.73 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 87.7 * (1 + (-0.268/100) * (-10 - 25)) = 95.93 V | OCPD = 1.56 * 1.75 = 2.73 A

Inputs from CEC Modules.csv for Caterpillar Inc PVT112 ARC: Voc=87.7 V, beta_Voc=-0.268%/C, Isc=1.75 A, STC=112.5 W, Area=0.72 m2.

Result: 6 panels max on 600 V (575.6 V); 72 panels for 8 kW (558 sq ft).

What Are the Published CEC Specifications for Caterpillar Inc PVT112 ARC?

Laboratory test ratings recorded for Caterpillar Inc PVT112 ARC (Thin Film) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Caterpillar Inc PVT112 ARC.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 112.5 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 104.5 W (92.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 87.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 1.75 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 70.2 V / 1.6 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.268 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.62% (0.72 m2) Array roof footprint density
Cell Count & Technology 216 cells (Thin Film) Monofacial backsheet

How Many Caterpillar Inc PVT112 ARC Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (558 sq ft at 8 kW), and estimated Year-1 electric bill offset for Caterpillar Inc PVT112 ARC.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 54 6.08 kW 419 sq ft $1,522 $2,573
8 kW Class 72 8.1 kW 558 sq ft $2,027 $3,428
10 kW Class 89 10.01 kW 690 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This Caterpillar Inc Series?

Sibling wattage bins and frame colors grouped with Caterpillar Inc PVT112 ARC under Caterpillar Inc to prevent duplicate spec pages.

Sibling CEC listings grouped into the Caterpillar Inc PVT112 ARC wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Caterpillar Inc PVT105 ARC 105.0 W 97.4 W 86.0 V 67.8 V 14.58%
Caterpillar Inc PVT107 ARC 107.5 W 99.7 W 86.6 V 68.6 V 14.93%
Caterpillar Inc PVT110 ARC 110.0 W 102.1 W 87.2 V 69.4 V 15.28%
Caterpillar Inc PVT112 ARC 112.5 W 104.5 W 87.7 V 70.2 V 15.62%
Caterpillar Inc PVT115 ARC 115.0 W 105.2 W 87.8 V 70.5 V 15.97%
Caterpillar Inc PVT117 ARC 117.5 W 107.5 W 88.2 V 71.2 V 16.32%

How Many Caterpillar Inc PVT112 ARC Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Caterpillar Inc PVT112 ARC (beta_Voc -0.268%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=87.7V and beta_Voc=-0.268%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 98.28 V 6 panels 589.7 V 10 panels
-10 C (14 F) 95.93 V 6 panels 575.6 V 10 panels
0 C (32 F) 93.58 V 6 panels 561.5 V 10 panels
25 C (77 F STC) 87.7 V 6 panels 526.2 V 11 panels

Which Cross-Brand Solar Modules Compare Closest to Caterpillar Inc PVT112 ARC?

Closest cross-brand CEC competitors to Caterpillar Inc PVT112 ARC matched near 112.5 W STC and 87.7 V Voc, led by First Solar Inc FS-4112-2.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
First Solar Inc FS-4112-2
First Solar Inc
112.5 W Tie (0 W) 87.7 V 15.62% 92.9%
First Solar Inc FS-4112A-2
First Solar Inc
112.5 W Tie (0 W) 87.7 V 15.62% 92.9%
First Solar Inc FS-4112-3
First Solar Inc
112.5 W Tie (0 W) 87.0 V 15.62% 93.2%
First Solar Inc FS-4112A-3
First Solar Inc
112.5 W Tie (0 W) 87.0 V 15.62% 93.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Caterpillar Inc PVT112 ARC?

Evaluate Caterpillar Inc PVT112 ARC (112.5 W STC, 87.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Caterpillar Inc PVT112 ARC reaches 98.28 V per panel—exceeding 6 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 72 panels for an 8 kW build require 558 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 72 panels (558 sq ft).
  • 2026 tax credit baseline: cash residential installs of Caterpillar Inc PVT112 ARC carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Caterpillar Inc PVT112 ARC 8 kW Residential Fit

Needs 72 modules (558 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 6 panels (-10 C) or 6 panels (-20 C), or compare First Solar Inc FS-4112-2.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 104.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Caterpillar Inc PVT112 ARC by Caterpillar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

How many Caterpillar Inc PVT112 ARC panels fit on a 600 V winter solar string?

At -10 C (14 F), Caterpillar Inc PVT112 ARC cold Voc rises from 87.7 V to 95.93 V (beta_Voc -0.268%/C), capping a 600 V string at 6 panels (575.6 V).

How much roof area does an 8 kW array of Caterpillar Inc PVT112 ARC need?

An 8 kW DC system uses 72 Caterpillar Inc PVT112 ARC modules (8,100 W STC / 7,524 W PTC), covering roughly 558 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

How does Caterpillar Inc PVT112 ARC compare against First Solar Inc FS-4112-2?

Caterpillar Inc PVT112 ARC outputs 112.5 W STC (87.7 V Voc, rank #21,521 of 21,677), while First Solar Inc FS-4112-2 delivers 112.5 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.