First Solar Inc FS-4112A-3 is a 112.5 W STC (104.9 W PTC) Thin Film solar module ranking #21,521 of 21,677 CEC listings (below all-CEC median; higher than 0.7% of peers). It delivers 15.62% efficiency, 87.0 V Voc at 25 C, and 97.93 V cold Voc at -10 C (6 panels max per 600 V string).
- STC Wattage
- 112.5 W
- PTC Wattage
- 104.9 W
- Voc @ 25C
- 87.0 V
- Efficiency
- 15.62%
How Does First Solar Inc FS-4112A-3 Compare Against Peer CEC Listings?
How First Solar Inc First Solar Inc FS-4112A-3 handles rooftop heat (104.9 W PTC), 8 kW sizing, and cold winter string voltage.
First Solar Inc builds the First Solar Inc FS-4112A-3 (Thin Film) as a compact residential or specialty off-grid module delivering 156.2 W/m2 (4.29 percentage points below 19.91% CEC median). Compared against Caterpillar Inc PVT112 (112.5 W), this model holds strong 93.2% PTC-to-STC heat retention (#8,924 of 21,677). Higher 87.0 V open-circuit voltage caps 600 V residential strings at 6 panels at 14 F (-10 C), while NEC 690.8 sets a 2.85 A overcurrent floor served by a 15 A breaker.
Where Does First Solar Inc FS-4112A-3 Fall Across Listed CEC Models?
Where First Solar Inc FS-4112A-3 (112.5 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define First Solar Inc FS-4112A-3?
Percentile placement of First Solar Inc FS-4112A-3 across power density (156.2 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for First Solar Inc FS-4112A-3?
Four critical engineering numbers homeowners and solar installers check first when reviewing First Solar Inc FS-4112A-3 specifications. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
112.5 W STC · Higher Than 0.7%
112.5 W STC (-272.5 W vs all-CEC median) vs 117.5 W Thin Film median.
15.62% Aperture Efficiency
Power density 156.2 W/m2 (4.29 percentage points below 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).
6 Panels Max @ -10 C (600 V)
Cold Voc reaches 97.93 V at -10 C (587.6 V string) and 101.05 V at -20 C (5 max).
72 Panels = 8,100 W STC
Occupies 51.8 m2 (558 sq ft) producing 7,553 W PTC; NEC 690.8 OCPD floor is 2.85 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 87.0 * (1 + (-0.359/100) * (-10 - 25)) = 97.93 V | OCPD = 1.56 * 1.83 = 2.85 A
Inputs from CEC Modules.csv for First Solar Inc FS-4112A-3: Voc=87.0 V, beta_Voc=-0.359%/C, Isc=1.83 A, STC=112.5 W, Area=0.72 m2.
Result: 6 panels max on 600 V (587.6 V); 72 panels for 8 kW (558 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-4112A-3?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for First Solar Inc FS-4112A-3.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 112.5 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 104.9 W (93.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 87.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 1.83 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 68.5 V / 1.64 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.359 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.62% (0.72 m2) | Array roof footprint density |
| Cell Count & Technology | 216 cells (Thin Film) | Monofacial backsheet |
How Many First Solar Inc FS-4112A-3 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using First Solar Inc FS-4112A-3 (112.5 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 54 | 6.08 kW | 419 sq ft | $1,522 | $2,573 |
| 8 kW Class | 72 | 8.1 kW | 558 sq ft | $2,027 | $3,428 |
| 10 kW Class | 89 | 10.01 kW | 690 sq ft | $2,505 | $4,236 |
How Many First Solar Inc FS-4112A-3 Modules Fit in a Cold-Weather String?
Maximum series module counts for First Solar Inc FS-4112A-3 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 101.05 V | 5 panels | 505.2 V | 9 panels |
| -10 C (14 F) | 97.93 V | 6 panels | 587.6 V | 10 panels |
| 0 C (32 F) | 94.81 V | 6 panels | 568.9 V | 10 panels |
| 25 C (77 F STC) | 87.0 V | 6 panels | 522.0 V | 11 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-4112A-3?
Alternative CEC solar modules from competing brands near First Solar Inc FS-4112A-3 (112.5 W), including Caterpillar Inc PVT112.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Caterpillar Inc PVT112 Caterpillar Inc |
112.5 W | Tie (0 W) | 87.7 V | 15.62% | 92.9% |
| Caterpillar Inc PVT112 ARC Caterpillar Inc |
112.5 W | Tie (0 W) | 87.7 V | 15.62% | 92.9% |
| Toledo Solar Inc TS1 Toledo Solar Inc |
115.0 W | +2.5 W | 87.1 V | 15.97% | 92.9% |
| T-Solar Global TS102 T-Solar Global |
102.5 W | -10.0 W | 93.0 V | 7.19% | 93.0% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-4112A-3?
Evaluate First Solar Inc FS-4112A-3 (112.5 W STC, 87.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-4112A-3 reaches 101.05 V per panel—exceeding 5 panels in series voids 600 V inverter warranties.
- Footprint constraint: 72 panels for an 8 kW build require 558 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 72 panels (558 sq ft).
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-4112A-3 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-4112A-3 8 kW Residential Fit
Needs 72 modules (558 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 6 panels (-10 C) or 5 panels (-20 C), or compare Caterpillar Inc PVT112.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 104.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-4112A-3 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for First Solar Inc FS-4112A-3?
Multiplying First Solar Inc FS-4112A-3's 1.83 A short-circuit current by 1.56 equals 2.85 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can First Solar Inc FS-4112A-3 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 97.93 V cold Voc at 14 F and handles 1.83 A Isc; string inverters cap First Solar Inc FS-4112A-3 at 6 panels on 600 V.
Is First Solar Inc FS-4112A-3 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of First Solar Inc FS-4112A-3 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)