Manufacturer: First Solar Inc Registry: CEC Verified Engineering Specification

First Solar Inc FS-7540A-FT1 is a 540.0 W STC (502.7 W PTC) CdTe solar module ranking #3,265 of 21,677 CEC listings (top 16.3%; higher than 83.7% of peers). It delivers 19.29% efficiency, 227.7 V Voc at 25 C, and 249.38 V cold Voc at -10 C (2 panels max per 600 V string).

STC Wattage
540.0 W
PTC Wattage
502.7 W
Voc @ 25C
227.7 V
Efficiency
19.29%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does First Solar Inc FS-7540A-FT1 Compare Against Peer CEC Listings?

How First Solar Inc First Solar Inc FS-7540A-FT1 handles rooftop heat (502.7 W PTC), 8 kW sizing, and cold winter string voltage.

First Solar Inc builds the First Solar Inc FS-7540A-FT1 (CdTe) as a large-format commercial and ground-mount module delivering 192.9 W/m2 (0.62 percentage points below 19.91% CEC median). Compared against Auxin Solar AXN10M540B (540.0 W), this model holds strong 93.1% PTC-to-STC heat retention (#9,420 of 21,677). Higher 227.7 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C), while NEC 690.8 sets a 4.77 A overcurrent floor served by a 15 A breaker.

Where Does First Solar Inc FS-7540A-FT1 Fall Across Listed CEC Models?

Where First Solar Inc FS-7540A-FT1 (540.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where First Solar Inc FS-7540A-FT1 (540.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFirst Solar Inc FS: 540.0 W

What Dataset Percentiles Define First Solar Inc FS-7540A-FT1?

Percentile placement of First Solar Inc FS-7540A-FT1 across power density (192.9 W/m2), thermal retention, and nameplate STC wattage.

First Solar Inc FS-7540A-FT1 Engineering BenchmarksPercentile comparison of First Solar Inc FS-7540A-FT1 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage540.0 WPTC/STC Retention93.1%Module Efficiency19.29%

What Do the Dataset Ranks Show for First Solar Inc FS-7540A-FT1?

Four critical engineering numbers homeowners and solar installers check first when reviewing First Solar Inc FS-7540A-FT1 specifications. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Rank #3,265 / 21,677

Top 16.3% STC Output

540.0 W STC (+155.0 W vs all-CEC median) vs 445.0 W CdTe median.

Eff #12,743

19.29% Aperture Efficiency

Power density 192.9 W/m2 (0.62 percentage points below 19.91% CEC median). PTC/STC ratio: 93.1% (rank #9,420).

NEC 690.7 Limit

2 Panels Max @ -10 C (600 V)

Cold Voc reaches 249.38 V at -10 C (498.8 V string) and 255.57 V at -20 C (2 max).

8 kW Reference Array

15 Panels = 8,100 W STC

Occupies 42.0 m2 (452 sq ft) producing 7,540 W PTC; NEC 690.8 OCPD floor is 4.77 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 227.7 * (1 + (-0.272/100) * (-10 - 25)) = 249.38 V | OCPD = 1.56 * 3.06 = 4.77 A

Inputs from CEC Modules.csv for First Solar Inc FS-7540A-FT1: Voc=227.7 V, beta_Voc=-0.272%/C, Isc=3.06 A, STC=540.0 W, Area=2.8 m2.

Result: 2 panels max on 600 V (498.8 V); 15 panels for 8 kW (452 sq ft).

What Are the Published CEC Specifications for First Solar Inc FS-7540A-FT1?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for First Solar Inc FS-7540A-FT1.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-7540A-FT1.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 540.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 502.7 W (93.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 227.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 3.06 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 188.7 V / 2.86 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.272 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.29% (2.8 m2) Array roof footprint density
Cell Count & Technology 268 cells (CdTe) Monofacial backsheet

How Many First Solar Inc FS-7540A-FT1 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using First Solar Inc FS-7540A-FT1 (540.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.48 kW 362 sq ft $1,622 $2,742
8 kW Class 15 8.1 kW 452 sq ft $2,027 $3,428
10 kW Class 19 10.26 kW 573 sq ft $2,568 $4,342

How Many First Solar Inc FS-7540A-FT1 Modules Fit in a Cold-Weather String?

Maximum series module counts for First Solar Inc FS-7540A-FT1 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=227.7V and beta_Voc=-0.272%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 255.57 V 2 panels 511.1 V 3 panels
-10 C (14 F) 249.38 V 2 panels 498.8 V 4 panels
0 C (32 F) 243.18 V 2 panels 486.4 V 4 panels
25 C (77 F STC) 227.7 V 2 panels 455.4 V 4 panels

Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-7540A-FT1?

Alternative CEC solar modules from competing brands near First Solar Inc FS-7540A-FT1 (540.0 W), including Auxin Solar AXN10M540B.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN10M540B
Auxin Solar
540.0 W Tie (0 W) 49.65 V 21.51% 94.0%
Auxin Solar AXN10M540W
Auxin Solar
540.0 W Tie (0 W) 49.65 V 21.51% 93.5%
Convalt Manufacturing LLC CVLT540-144MH
Convalt Manufacturing LLC
540.0 W Tie (0 W) 49.65 V 21.26% 92.5%
AMPS Solar AMPS-540P-72BB
AMPS Solar
540.0 W Tie (0 W) 49.6 V 21.09% 94.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-7540A-FT1?

Evaluate First Solar Inc FS-7540A-FT1 (540.0 W STC, 227.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-7540A-FT1 reaches 255.57 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 452 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of First Solar Inc FS-7540A-FT1 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

First Solar Inc FS-7540A-FT1 8 kW Residential Fit

Needs 15 modules (452 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Auxin Solar AXN10M540B.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 502.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-7540A-FT1 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for First Solar Inc FS-7540A-FT1?

Multiplying First Solar Inc FS-7540A-FT1's 3.06 A short-circuit current by 1.56 equals 4.77 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can First Solar Inc FS-7540A-FT1 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 249.38 V cold Voc at 14 F and handles 3.06 A Isc; string inverters cap First Solar Inc FS-7540A-FT1 at 2 panels on 600 V.

Is First Solar Inc FS-7540A-FT1 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of First Solar Inc FS-7540A-FT1 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.