First Solar Inc FS-4112A-2 is a 112.5 W STC (104.5 W PTC) Thin Film solar module ranking #21,521 of 21,677 CEC listings (below all-CEC median; higher than 0.7% of peers). It delivers 15.62% efficiency, 87.7 V Voc at 25 C, and 95.93 V cold Voc at -10 C (6 panels max per 600 V string).
- STC Wattage
- 112.5 W
- PTC Wattage
- 104.5 W
- Voc @ 25C
- 87.7 V
- Efficiency
- 15.62%
How Does First Solar Inc FS-4112A-2 Compare Against Peer CEC Listings?
Engineering position of First Solar Inc FS-4112A-2 (112.5 W STC) vs. Caterpillar Inc PVT112 across 106 CEC Thin Film solar modules.
Ranking #21,521 across 21,677 CEC solar panels (below all-CEC median; higher than 0.7% of peers), First Solar Inc FS-4112A-2 operates as a compact residential or specialty off-grid module sitting 5.0 W below the 117.5 W Thin Film median. Higher 87.7 V open-circuit voltage caps 600 V residential strings at 6 panels at 14 F (-10 C). With strong 92.9% PTC-to-STC heat retention (#10,348 of 21,677), 72 panels occupy 558 sq ft and offset roughly $2,027/yr at average US rates (or $3,428/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does First Solar Inc FS-4112A-2 Fall Across Listed CEC Models?
Plots First Solar Inc FS-4112A-2 at 112.5 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define First Solar Inc FS-4112A-2?
Benchmarks First Solar Inc FS-4112A-2 on STC wattage, thermal PTC/STC retention, and 15.62 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for First Solar Inc FS-4112A-2?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for First Solar Inc FS-4112A-2 by First Solar Inc.
112.5 W STC · Higher Than 0.7%
112.5 W STC (-272.5 W vs all-CEC median) vs 117.5 W Thin Film median.
15.62% Aperture Efficiency
Power density 156.2 W/m2 (4.29 percentage points below 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).
6 Panels Max @ -10 C (600 V)
Cold Voc reaches 95.93 V at -10 C (575.6 V string) and 98.28 V at -20 C (6 max).
72 Panels = 8,100 W STC
Occupies 51.8 m2 (558 sq ft) producing 7,524 W PTC; NEC 690.8 OCPD floor is 2.73 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 87.7 * (1 + (-0.268/100) * (-10 - 25)) = 95.93 V | OCPD = 1.56 * 1.75 = 2.73 A
Inputs from CEC Modules.csv for First Solar Inc FS-4112A-2: Voc=87.7 V, beta_Voc=-0.268%/C, Isc=1.75 A, STC=112.5 W, Area=0.72 m2.
Result: 6 panels max on 600 V (575.6 V); 72 panels for 8 kW (558 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-4112A-2?
Laboratory test ratings recorded for First Solar Inc FS-4112A-2 (Thin Film) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 112.5 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 104.5 W (92.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 87.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 1.75 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 70.2 V / 1.6 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.268 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.62% (0.72 m2) | Array roof footprint density |
| Cell Count & Technology | 216 cells (Thin Film) | Monofacial backsheet |
How Many First Solar Inc FS-4112A-2 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (558 sq ft at 8 kW), and estimated Year-1 electric bill offset for First Solar Inc FS-4112A-2.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 54 | 6.08 kW | 419 sq ft | $1,522 | $2,573 |
| 8 kW Class | 72 | 8.1 kW | 558 sq ft | $2,027 | $3,428 |
| 10 kW Class | 89 | 10.01 kW | 690 sq ft | $2,505 | $4,236 |
How Many First Solar Inc FS-4112A-2 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for First Solar Inc FS-4112A-2 (beta_Voc -0.268%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 98.28 V | 6 panels | 589.7 V | 10 panels |
| -10 C (14 F) | 95.93 V | 6 panels | 575.6 V | 10 panels |
| 0 C (32 F) | 93.58 V | 6 panels | 561.5 V | 10 panels |
| 25 C (77 F STC) | 87.7 V | 6 panels | 526.2 V | 11 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-4112A-2?
Closest cross-brand CEC competitors to First Solar Inc FS-4112A-2 matched near 112.5 W STC and 87.7 V Voc, led by Caterpillar Inc PVT112.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Caterpillar Inc PVT112 Caterpillar Inc |
112.5 W | Tie (0 W) | 87.7 V | 15.62% | 92.9% |
| Caterpillar Inc PVT112 ARC Caterpillar Inc |
112.5 W | Tie (0 W) | 87.7 V | 15.62% | 92.9% |
| Toledo Solar Inc TS1 Toledo Solar Inc |
115.0 W | +2.5 W | 87.1 V | 15.97% | 92.9% |
| T-Solar Global TS102 T-Solar Global |
102.5 W | -10.0 W | 93.0 V | 7.19% | 93.0% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-4112A-2?
Evaluate First Solar Inc FS-4112A-2 (112.5 W STC, 87.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-4112A-2 reaches 98.28 V per panel—exceeding 6 panels in series voids 600 V inverter warranties.
- Footprint constraint: 72 panels for an 8 kW build require 558 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 72 panels (558 sq ft).
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-4112A-2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-4112A-2 8 kW Residential Fit
Needs 72 modules (558 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 6 panels (-10 C) or 6 panels (-20 C), or compare Caterpillar Inc PVT112.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 104.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-4112A-2 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
How many First Solar Inc FS-4112A-2 panels fit on a 600 V winter solar string?
At -10 C (14 F), First Solar Inc FS-4112A-2 cold Voc rises from 87.7 V to 95.93 V (beta_Voc -0.268%/C), capping a 600 V string at 6 panels (575.6 V).
How much roof area does an 8 kW array of First Solar Inc FS-4112A-2 need?
An 8 kW DC system uses 72 First Solar Inc FS-4112A-2 modules (8,100 W STC / 7,524 W PTC), covering roughly 558 sq ft and saving ~$2,027/yr at 18.54 c/kWh.
How does First Solar Inc FS-4112A-2 compare against Caterpillar Inc PVT112?
First Solar Inc FS-4112A-2 outputs 112.5 W STC (87.7 V Voc, rank #21,521 of 21,677), while Caterpillar Inc PVT112 delivers 112.5 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)