Caterpillar Inc PVC370MP03H is a 370.0 W STC (348.1 W PTC) Mono-c-Si solar module ranking #11,697 of 21,677 CEC listings (below all-CEC median; higher than 44.4% of peers). It delivers 19.11% efficiency, 48.6 V Voc at 25 C, and 53.14 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 370.0 W
- PTC Wattage
- 348.1 W
- Voc @ 25C
- 48.6 V
- Efficiency
- 19.11%
How Does Caterpillar Inc PVC370MP03H Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Caterpillar Inc PVC370MP03H (Mono-c-Si) residential solar systems.
Homeowners evaluating Caterpillar Inc PVC370MP03H need 17 panels for 6 kW or 22 panels (458 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (458 sq ft). Under NEC 690.7(A), beta_Voc (-0.267%/C) pushes open-circuit voltage to 53.14 V at 14 F and 54.44 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Caterpillar Inc PVC370MP03H Fall Across Listed CEC Models?
Comparison of Caterpillar Inc PVC370MP03H (370.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What Dataset Percentiles Define Caterpillar Inc PVC370MP03H?
Relative ranking of Caterpillar Inc PVC370MP03H across nameplate watts, 94.1% PTC thermal ratio, and module aperture efficiency. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
What Do the Dataset Ranks Show for Caterpillar Inc PVC370MP03H?
Summary of Caterpillar Inc PVC370MP03H output rank, 8 kW array size (22 panels), efficiency rating, and 600 V string limit.
370.0 W STC · Higher Than 44.4%
370.0 W STC (-15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.11% Aperture Efficiency
Power density 191.1 W/m2 (0.80 percentage points below 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.14 V at -10 C (584.5 V string) and 54.44 V at -20 C (11 max).
22 Panels = 8,140 W STC
Occupies 42.6 m2 (458 sq ft) producing 7,658 W PTC; NEC 690.8 OCPD floor is 15.27 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.6 * (1 + (-0.267/100) * (-10 - 25)) = 53.14 V | OCPD = 1.56 * 9.79 = 15.27 A
Inputs from CEC Modules.csv for Caterpillar Inc PVC370MP03H: Voc=48.6 V, beta_Voc=-0.267%/C, Isc=9.79 A, STC=370.0 W, Area=1.936 m2.
Result: 11 panels max on 600 V (584.5 V); 22 panels for 8 kW (458 sq ft).
What Are the Published CEC Specifications for Caterpillar Inc PVC370MP03H?
Complete CEC test sheet for Caterpillar Inc PVC370MP03H including Isc (9.79 A), Voc (48.6 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 370.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 348.1 W (94.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.79 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.2 V / 9.21 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.267 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.11% (1.936 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Caterpillar Inc PVC370MP03H Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Caterpillar Inc PVC370MP03H.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.29 kW | 354 sq ft | $1,574 | $2,662 |
| 8 kW Class | 22 | 8.14 kW | 458 sq ft | $2,037 | $3,445 |
| 10 kW Class | 28 | 10.36 kW | 583 sq ft | $2,593 | $4,385 |
Which Sibling Wattage & Trim Variants Belong to This Caterpillar Inc Series?
Related Caterpillar Inc power steps and black/silver trims consolidated into this Caterpillar Inc PVC370MP03H series guide. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Caterpillar Inc PVC365MP03H | 365.0 W | 343.3 W | 48.4 V | 40.0 V | 18.85% |
| Caterpillar Inc PVC370MP03H | 370.0 W | 348.1 W | 48.6 V | 40.2 V | 19.11% |
How Many Caterpillar Inc PVC370MP03H Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Caterpillar Inc PVC370MP03H (48.6 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.44 V | 11 panels | 598.8 V | 18 panels |
| -10 C (14 F) | 53.14 V | 11 panels | 584.5 V | 18 panels |
| 0 C (32 F) | 51.84 V | 11 panels | 570.2 V | 19 panels |
| 25 C (77 F STC) | 48.6 V | 12 panels | 583.2 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Caterpillar Inc PVC370MP03H?
Four comparable CEC modules such as Bluesun Solar Energy Tech CoLtd BSM370M-72 (370.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Bluesun Solar Energy Tech CoLtd BSM370M-72 Bluesun Solar Energy Tech CoLtd |
370.0 W | Tie (0 W) | 48.23 V | 19.07% | 91.9% |
| CertainTeed CT370M00-04 CertainTeed |
370.0 W | Tie (0 W) | 47.9 V | 19.66% | 93.2% |
| CertainTeed CT375M00-04 CertainTeed |
375.0 W | +5.0 W | 48.2 V | 19.93% | 93.3% |
| AXITEC AC-375M/72S AXITEC |
375.0 W | +5.0 W | 48.16 V | 19.33% | 91.3% |
What Are the Design Limits and Best-Fit Uses for Caterpillar Inc PVC370MP03H?
Evaluate Caterpillar Inc PVC370MP03H (370.0 W STC, 48.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Caterpillar Inc PVC370MP03H reaches 54.44 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 458 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (458 sq ft).
- 2026 tax credit baseline: cash residential installs of Caterpillar Inc PVC370MP03H carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Caterpillar Inc PVC370MP03H 8 kW Residential Fit
Needs 22 modules (458 sq ft) with a 20 A string OCPD, offsetting ~$2,037/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Bluesun Solar Energy Tech CoLtd BSM370M-72.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 348.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Caterpillar Inc PVC370MP03H by Caterpillar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Caterpillar Inc PVC370MP03H PTC wattage (348.1 W) lower than STC (370.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 348.1 W PTC (94.1% retention) across Caterpillar Inc PVC370MP03H's 1.936 m2 aperture.
Who should skip Caterpillar Inc PVC370MP03H on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 22 Caterpillar Inc PVC370MP03H panels (458 sq ft) leave unusable roof gaps vs. Bluesun Solar Energy Tech CoLtd BSM370M-72.
What is the 1,000 V commercial string limit for Caterpillar Inc PVC370MP03H?
On 1,000 V commercial inverters at -10 C (53.14 V cold Voc), Caterpillar Inc PVC370MP03H fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Caterpillar Inc PVC370MP03H.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)