Skip to main content
WireAndSun
Calculators
CEC PV Module

Caterpillar Inc PVC370MP03H — CEC Solar Module Specifications

Manufacturer: Caterpillar Inc Registry: CEC Verified Engineering Specification

Caterpillar Inc PVC370MP03H is a 370.0 W STC (348.1 W PTC) Mono-c-Si solar module ranking #11,697 of 21,677 CEC listings (below all-CEC median; higher than 44.4% of peers). It delivers 19.11% efficiency, 48.6 V Voc at 25 C, and 53.14 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
370.0 W
PTC Wattage
348.1 W
Voc @ 25C
48.6 V
Efficiency
19.11%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Caterpillar Inc PVC370MP03H Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Caterpillar Inc PVC370MP03H (Mono-c-Si) residential solar systems.

Homeowners evaluating Caterpillar Inc PVC370MP03H need 17 panels for 6 kW or 22 panels (458 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (458 sq ft). Under NEC 690.7(A), beta_Voc (-0.267%/C) pushes open-circuit voltage to 53.14 V at 14 F and 54.44 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Caterpillar Inc PVC370MP03H Fall Across Listed CEC Models?

Comparison of Caterpillar Inc PVC370MP03H (370.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Caterpillar Inc PVC370MP03H (370.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCaterpillar Inc PV: 370.0 W

What Dataset Percentiles Define Caterpillar Inc PVC370MP03H?

Relative ranking of Caterpillar Inc PVC370MP03H across nameplate watts, 94.1% PTC thermal ratio, and module aperture efficiency. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Caterpillar Inc PVC370MP03H Engineering BenchmarksPercentile comparison of Caterpillar Inc PVC370MP03H wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage370.0 WPTC/STC Retention94.1%Module Efficiency19.11%

What Do the Dataset Ranks Show for Caterpillar Inc PVC370MP03H?

Summary of Caterpillar Inc PVC370MP03H output rank, 8 kW array size (22 panels), efficiency rating, and 600 V string limit.

Rank #11,697 / 21,677

370.0 W STC · Higher Than 44.4%

370.0 W STC (-15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #13,188

19.11% Aperture Efficiency

Power density 191.1 W/m2 (0.80 percentage points below 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.14 V at -10 C (584.5 V string) and 54.44 V at -20 C (11 max).

8 kW Reference Array

22 Panels = 8,140 W STC

Occupies 42.6 m2 (458 sq ft) producing 7,658 W PTC; NEC 690.8 OCPD floor is 15.27 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.6 * (1 + (-0.267/100) * (-10 - 25)) = 53.14 V | OCPD = 1.56 * 9.79 = 15.27 A

Inputs from CEC Modules.csv for Caterpillar Inc PVC370MP03H: Voc=48.6 V, beta_Voc=-0.267%/C, Isc=9.79 A, STC=370.0 W, Area=1.936 m2.

Result: 11 panels max on 600 V (584.5 V); 22 panels for 8 kW (458 sq ft).

What Are the Published CEC Specifications for Caterpillar Inc PVC370MP03H?

Complete CEC test sheet for Caterpillar Inc PVC370MP03H including Isc (9.79 A), Voc (48.6 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Caterpillar Inc PVC370MP03H.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 370.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 348.1 W (94.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.6 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.79 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.2 V / 9.21 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.267 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.11% (1.936 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Caterpillar Inc PVC370MP03H Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Caterpillar Inc PVC370MP03H.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.29 kW 354 sq ft $1,574 $2,662
8 kW Class 22 8.14 kW 458 sq ft $2,037 $3,445
10 kW Class 28 10.36 kW 583 sq ft $2,593 $4,385

Which Sibling Wattage & Trim Variants Belong to This Caterpillar Inc Series?

Related Caterpillar Inc power steps and black/silver trims consolidated into this Caterpillar Inc PVC370MP03H series guide. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the Caterpillar Inc PVC370MP03H wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Caterpillar Inc PVC365MP03H 365.0 W 343.3 W 48.4 V 40.0 V 18.85%
Caterpillar Inc PVC370MP03H 370.0 W 348.1 W 48.6 V 40.2 V 19.11%

How Many Caterpillar Inc PVC370MP03H Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Caterpillar Inc PVC370MP03H (48.6 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=48.6V and beta_Voc=-0.267%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.44 V 11 panels 598.8 V 18 panels
-10 C (14 F) 53.14 V 11 panels 584.5 V 18 panels
0 C (32 F) 51.84 V 11 panels 570.2 V 19 panels
25 C (77 F STC) 48.6 V 12 panels 583.2 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Caterpillar Inc PVC370MP03H?

Four comparable CEC modules such as Bluesun Solar Energy Tech CoLtd BSM370M-72 (370.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Bluesun Solar Energy Tech CoLtd BSM370M-72
Bluesun Solar Energy Tech CoLtd
370.0 W Tie (0 W) 48.23 V 19.07% 91.9%
CertainTeed CT370M00-04
CertainTeed
370.0 W Tie (0 W) 47.9 V 19.66% 93.2%
CertainTeed CT375M00-04
CertainTeed
375.0 W +5.0 W 48.2 V 19.93% 93.3%
AXITEC AC-375M/72S
AXITEC
375.0 W +5.0 W 48.16 V 19.33% 91.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Caterpillar Inc PVC370MP03H?

Evaluate Caterpillar Inc PVC370MP03H (370.0 W STC, 48.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Caterpillar Inc PVC370MP03H reaches 54.44 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 458 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (458 sq ft).
  • 2026 tax credit baseline: cash residential installs of Caterpillar Inc PVC370MP03H carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Caterpillar Inc PVC370MP03H 8 kW Residential Fit

Needs 22 modules (458 sq ft) with a 20 A string OCPD, offsetting ~$2,037/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Bluesun Solar Energy Tech CoLtd BSM370M-72.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 348.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Caterpillar Inc PVC370MP03H by Caterpillar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Caterpillar Inc PVC370MP03H PTC wattage (348.1 W) lower than STC (370.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 348.1 W PTC (94.1% retention) across Caterpillar Inc PVC370MP03H's 1.936 m2 aperture.

Who should skip Caterpillar Inc PVC370MP03H on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 22 Caterpillar Inc PVC370MP03H panels (458 sq ft) leave unusable roof gaps vs. Bluesun Solar Energy Tech CoLtd BSM370M-72.

What is the 1,000 V commercial string limit for Caterpillar Inc PVC370MP03H?

On 1,000 V commercial inverters at -10 C (53.14 V cold Voc), Caterpillar Inc PVC370MP03H fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Caterpillar Inc PVC370MP03H.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.