Manufacturer: CertainTeed Registry: CEC Verified Engineering Specification

CertainTeed CT375M00-04 is a 375.0 W STC (349.7 W PTC) Mono-c-Si solar module ranking #11,367 of 21,677 CEC listings (below all-CEC median; higher than 46.0% of peers). It delivers 19.93% efficiency, 48.2 V Voc at 25 C, and 52.86 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
375.0 W
PTC Wattage
349.7 W
Voc @ 25C
48.2 V
Efficiency
19.93%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does CertainTeed CT375M00-04 Compare Against Peer CEC Listings?

How CertainTeed CertainTeed CT375M00-04 handles rooftop heat (349.7 W PTC), 8 kW sizing, and cold winter string voltage.

CertainTeed builds the CertainTeed CT375M00-04 (Mono-c-Si) as a compact residential or specialty off-grid module delivering 199.3 W/m2 (0.02 percentage points above 19.91% CEC median). Compared against AXITEC AC-375M/72S (375.0 W), this model holds strong 93.3% PTC-to-STC heat retention (#8,323 of 21,677). Higher 48.2 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), while NEC 690.8 sets a 15.44 A overcurrent floor served by a 20 A breaker.

Where Does CertainTeed CT375M00-04 Fall Across Listed CEC Models?

Where CertainTeed CT375M00-04 (375.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where CertainTeed CT375M00-04 (375.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCertainTeed CT375M: 375.0 W

What Dataset Percentiles Define CertainTeed CT375M00-04?

Percentile placement of CertainTeed CT375M00-04 across power density (199.3 W/m2), thermal retention, and nameplate STC wattage. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

CertainTeed CT375M00-04 Engineering BenchmarksPercentile comparison of CertainTeed CT375M00-04 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage375.0 WPTC/STC Retention93.3%Module Efficiency19.93%

What Do the Dataset Ranks Show for CertainTeed CT375M00-04?

Four critical engineering numbers homeowners and solar installers check first when reviewing CertainTeed CT375M00-04 specifications. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Rank #11,367 / 21,677

375.0 W STC · Higher Than 46.0%

375.0 W STC (-10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #10,795

19.93% Aperture Efficiency

Power density 199.3 W/m2 (0.02 percentage points above 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.86 V at -10 C (581.5 V string) and 54.19 V at -20 C (11 max).

8 kW Reference Array

22 Panels = 8,250 W STC

Occupies 41.4 m2 (446 sq ft) producing 7,693 W PTC; NEC 690.8 OCPD floor is 15.44 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.2 * (1 + (-0.276/100) * (-10 - 25)) = 52.86 V | OCPD = 1.56 * 9.9 = 15.44 A

Inputs from CEC Modules.csv for CertainTeed CT375M00-04: Voc=48.2 V, beta_Voc=-0.276%/C, Isc=9.9 A, STC=375.0 W, Area=1.882 m2.

Result: 11 panels max on 600 V (581.5 V); 22 panels for 8 kW (446 sq ft).

What Are the Published CEC Specifications for CertainTeed CT375M00-04?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for CertainTeed CT375M00-04. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for CertainTeed CT375M00-04.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 375.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 349.7 W (93.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.9 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.2 V / 9.3 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.276 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.93% (1.882 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many CertainTeed CT375M00-04 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using CertainTeed CT375M00-04 (375.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.0 kW 324 sq ft $1,502 $2,539
8 kW Class 22 8.25 kW 446 sq ft $2,065 $3,492
10 kW Class 27 10.12 kW 547 sq ft $2,533 $4,283

How Many CertainTeed CT375M00-04 Modules Fit in a Cold-Weather String?

Maximum series module counts for CertainTeed CT375M00-04 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=48.2V and beta_Voc=-0.276%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.19 V 11 panels 596.1 V 18 panels
-10 C (14 F) 52.86 V 11 panels 581.5 V 18 panels
0 C (32 F) 51.53 V 11 panels 566.8 V 19 panels
25 C (77 F STC) 48.2 V 12 panels 578.4 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to CertainTeed CT375M00-04?

Alternative CEC solar modules from competing brands near CertainTeed CT375M00-04 (375.0 W), including AXITEC AC-375M/72S. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-375M/72S
AXITEC
375.0 W Tie (0 W) 48.16 V 19.33% 91.3%
AXITEC AC-375M/72V
AXITEC
375.0 W Tie (0 W) 48.16 V 19.33% 91.3%
Boviet Solar Technology Co Ltd BVM6612M-375
Boviet Solar Technology Co Ltd
375.0 W Tie (0 W) 48.0 V 19.33% 92.4%
CSI Solar Co Ltd CS3U-375MS
CSI Solar Co Ltd
375.0 W Tie (0 W) 47.6 V 19.54% 93.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for CertainTeed CT375M00-04?

Evaluate CertainTeed CT375M00-04 (375.0 W STC, 48.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), CertainTeed CT375M00-04 reaches 54.19 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 446 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (446 sq ft).
  • 2026 tax credit baseline: cash residential installs of CertainTeed CT375M00-04 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

CertainTeed CT375M00-04 8 kW Residential Fit

Needs 22 modules (446 sq ft) with a 20 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-375M/72S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 349.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for CertainTeed CT375M00-04 by CertainTeed grounded in CEC test data and NEC 690.7/690.8 limits. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

What fuse or breaker size does NEC 690.8 require for CertainTeed CT375M00-04?

Multiplying CertainTeed CT375M00-04's 9.9 A short-circuit current by 1.56 equals 15.44 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker. Check local building department permit requirements for CertainTeed CT375M00-04 before finalizing component orders.

Can CertainTeed CT375M00-04 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 52.86 V cold Voc at 14 F and handles 9.9 A Isc; string inverters cap CertainTeed CT375M00-04 at 11 panels on 600 V.

Is CertainTeed CT375M00-04 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of CertainTeed CT375M00-04 rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.