Skip to main content
WireAndSun
Calculators
CEC PV Module

Heliene 72P265 — CEC Solar Module Specifications

Manufacturer: Heliene Registry: CEC Verified Engineering Specification

Heliene 72P265 is a 265.0 W STC (234.1 W PTC) Multi-c-Si solar module ranking #18,880 of 21,677 CEC listings (below all-CEC median; higher than 11.7% of peers). It delivers 13.57% efficiency, 42.85 V Voc at 25 C, and 47.6 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
265.0 W
PTC Wattage
234.1 W
Voc @ 25C
42.85 V
Efficiency
13.57%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Heliene 72P265 Compare Against Peer CEC Listings?

How Heliene Heliene 72P265 handles rooftop heat (234.1 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Heliene 72P265 exhibits 8.13 A short-circuit current, requiring a 12.68 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #18,880 of 21,677 (13.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 60.5 m2 for an 8 kW system (38 panels for 10 kW). Mid-range 42.85 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.

Where Does Heliene 72P265 Fall Across Listed CEC Models?

Where Heliene 72P265 (265.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Heliene 72P265 (265.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHeliene 72P265: 265.0 W

What Dataset Percentiles Define Heliene 72P265?

Percentile placement of Heliene 72P265 across power density (135.8 W/m2), thermal retention, and nameplate STC wattage. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Heliene 72P265 Engineering BenchmarksPercentile comparison of Heliene 72P265 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage265.0 WPTC/STC Retention88.3%Module Efficiency13.57%

What Do the Dataset Ranks Show for Heliene 72P265?

Four critical engineering numbers homeowners and solar installers check first when reviewing Heliene 72P265 specifications. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Rank #18,880 / 21,677

265.0 W STC · Higher Than 11.7%

265.0 W STC (-120.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,181

13.57% Aperture Efficiency

Power density 135.8 W/m2 (6.34 percentage points below 19.91% CEC median). PTC/STC ratio: 88.3% (rank #21,245).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 47.6 V at -10 C (571.2 V string) and 48.96 V at -20 C (12 max).

8 kW Reference Array

31 Panels = 8,215 W STC

Occupies 60.5 m2 (651 sq ft) producing 7,257 W PTC; NEC 690.8 OCPD floor is 12.68 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 42.85 * (1 + (-0.317/100) * (-10 - 25)) = 47.6 V | OCPD = 1.56 * 8.13 = 12.68 A

Inputs from CEC Modules.csv for Heliene 72P265: Voc=42.85 V, beta_Voc=-0.317%/C, Isc=8.13 A, STC=265.0 W, Area=1.952 m2.

Result: 12 panels max on 600 V (571.2 V); 31 panels for 8 kW (651 sq ft).

What Are the Published CEC Specifications for Heliene 72P265?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Heliene 72P265. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Official California Energy Commission (NREL SAM) test parameters for Heliene 72P265.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 265.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 234.1 W (88.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 42.85 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.13 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.8 V / 7.6 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.317 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.57% (1.952 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Heliene 72P265 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Heliene 72P265 (265.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 23 6.09 kW 483 sq ft $1,524 $2,577
8 kW Class 31 8.21 kW 651 sq ft $2,055 $3,475
10 kW Class 38 10.07 kW 798 sq ft $2,520 $4,262

Which Sibling Wattage & Trim Variants Belong to This Heliene Series?

All closely matched Heliene wattages and cosmetic trims sharing the Heliene 72P265 architecture. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sibling CEC listings grouped into the Heliene 72P265 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Heliene 72P260 260.0 W 229.6 W 42.62 V 34.65 V 13.32%
Heliene 72P265 265.0 W 234.1 W 42.85 V 34.8 V 13.57%
Heliene 72P270 270.0 W 238.7 W 43.05 V 35.0 V 13.83%

How Many Heliene 72P265 Modules Fit in a Cold-Weather String?

Maximum series module counts for Heliene 72P265 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=42.85V and beta_Voc=-0.317%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 48.96 V 12 panels 587.5 V 20 panels
-10 C (14 F) 47.6 V 12 panels 571.2 V 21 panels
0 C (32 F) 46.25 V 12 panels 555.0 V 21 panels
25 C (77 F STC) 42.85 V 14 panels 599.9 V 23 panels

Which Cross-Brand Solar Modules Compare Closest to Heliene 72P265?

Alternative CEC solar modules from competing brands near Heliene 72P265 (265.0 W), including BYD Company Limited BYD 265P6C-36.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
BYD Company Limited BYD 265P6C-36
BYD Company Limited
265.0 W Tie (0 W) 43.11 V 13.66% 90.9%
Advance Power API-P265
Advance Power
265.0 W Tie (0 W) 43.27 V 13.58% 89.1%
Auxin Solar AXN6P610T265
Auxin Solar
265.0 W Tie (0 W) 43.27 V 13.58% 89.1%
Anhui Rinengzhongtian Semiconductor Development QJP265-72
Anhui Rinengzhongtian Semiconductor Development
265.0 W Tie (0 W) 42.3 V 13.66% 89.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Heliene 72P265?

Evaluate Heliene 72P265 (265.0 W STC, 42.85 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Heliene 72P265 reaches 48.96 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 31 panels for an 8 kW build require 651 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (651 sq ft).
  • 2026 tax credit baseline: cash residential installs of Heliene 72P265 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Heliene 72P265 8 kW Residential Fit

Needs 31 modules (651 sq ft) with a 15 A string OCPD, offsetting ~$2,055/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare BYD Company Limited BYD 265P6C-36.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 234.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Heliene 72P265 by Heliene grounded in CEC test data and NEC 690.7/690.8 limits. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Why is Heliene 72P265 PTC wattage (234.1 W) lower than STC (265.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 234.1 W PTC (88.3% retention) across Heliene 72P265's 1.952 m2 aperture.

Who should skip Heliene 72P265 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 31 Heliene 72P265 panels (651 sq ft) leave unusable roof gaps vs. BYD Company Limited BYD 265P6C-36.

What is the 1,000 V commercial string limit for Heliene 72P265?

On 1,000 V commercial inverters at -10 C (47.6 V cold Voc), Heliene 72P265 fits up to 21 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Heliene 72P265.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.