Skip to main content
WireAndSun
Calculators
CEC PV Module

Advance Power API-P265 — CEC Solar Module Specifications

Manufacturer: Advance Power Registry: CEC Verified Engineering Specification

Advance Power API-P265 is a 265.0 W STC (236.0 W PTC) Multi-c-Si solar module ranking #18,880 of 21,677 CEC listings (below all-CEC median; higher than 11.7% of peers). It delivers 13.58% efficiency, 43.27 V Voc at 25 C, and 48.33 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
265.0 W
PTC Wattage
236.0 W
Voc @ 25C
43.27 V
Efficiency
13.58%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Advance Power API-P265 Compare Against Peer CEC Listings?

How Advance Power Advance Power API-P265 handles rooftop heat (236.0 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Advance Power API-P265 exhibits 7.95 A short-circuit current, requiring a 12.4 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #18,880 of 21,677 (13.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 60.5 m2 for an 8 kW system (38 panels for 10 kW). Mid-range 43.27 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.

Where Does Advance Power API-P265 Fall Across Listed CEC Models?

Where Advance Power API-P265 (265.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Advance Power API-P265 (265.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAdvance Power API-: 265.0 W

What Dataset Percentiles Define Advance Power API-P265?

Percentile placement of Advance Power API-P265 across power density (135.8 W/m2), thermal retention, and nameplate STC wattage.

Advance Power API-P265 Engineering BenchmarksPercentile comparison of Advance Power API-P265 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage265.0 WPTC/STC Retention89.1%Module Efficiency13.58%

What Do the Dataset Ranks Show for Advance Power API-P265?

Four critical engineering numbers homeowners and solar installers check first when reviewing Advance Power API-P265 specifications. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Rank #18,880 / 21,677

265.0 W STC · Higher Than 11.7%

265.0 W STC (-120.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,170

13.58% Aperture Efficiency

Power density 135.8 W/m2 (6.33 percentage points below 19.91% CEC median). PTC/STC ratio: 89.1% (rank #20,440).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 48.33 V at -10 C (580.0 V string) and 49.77 V at -20 C (12 max).

8 kW Reference Array

31 Panels = 8,215 W STC

Occupies 60.5 m2 (651 sq ft) producing 7,316 W PTC; NEC 690.8 OCPD floor is 12.4 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.27 * (1 + (-0.334/100) * (-10 - 25)) = 48.33 V | OCPD = 1.56 * 7.95 = 12.4 A

Inputs from CEC Modules.csv for Advance Power API-P265: Voc=43.27 V, beta_Voc=-0.334%/C, Isc=7.95 A, STC=265.0 W, Area=1.951 m2.

Result: 12 panels max on 600 V (580.0 V); 31 panels for 8 kW (651 sq ft).

What Are the Published CEC Specifications for Advance Power API-P265?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Advance Power API-P265.

Official California Energy Commission (NREL SAM) test parameters for Advance Power API-P265.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 265.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 236.0 W (89.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 43.27 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 7.95 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.14 V / 7.33 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.334 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.58% (1.951 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Advance Power API-P265 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Advance Power API-P265 (265.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 23 6.09 kW 483 sq ft $1,524 $2,577
8 kW Class 31 8.21 kW 651 sq ft $2,055 $3,475
10 kW Class 38 10.07 kW 798 sq ft $2,520 $4,262

Which Sibling Wattage & Trim Variants Belong to This Advance Power Series?

All closely matched Advance Power wattages and cosmetic trims sharing the Advance Power API-P265 architecture. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sibling CEC listings grouped into the Advance Power API-P265 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Advance Power API-P260 260.0 W 231.5 W 43.2 V 35.93 V 13.33%
Advance Power API-P265 265.0 W 236.0 W 43.27 V 36.14 V 13.58%

How Many Advance Power API-P265 Modules Fit in a Cold-Weather String?

Maximum series module counts for Advance Power API-P265 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=43.27V and beta_Voc=-0.334%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 49.77 V 12 panels 597.2 V 20 panels
-10 C (14 F) 48.33 V 12 panels 580.0 V 20 panels
0 C (32 F) 46.88 V 12 panels 562.6 V 21 panels
25 C (77 F STC) 43.27 V 13 panels 562.5 V 23 panels

Which Cross-Brand Solar Modules Compare Closest to Advance Power API-P265?

Alternative CEC solar modules from competing brands near Advance Power API-P265 (265.0 W), including Auxin Solar AXN6P610T265. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN6P610T265
Auxin Solar
265.0 W Tie (0 W) 43.27 V 13.58% 89.1%
BYD Company Limited BYD 265P6C-36
BYD Company Limited
265.0 W Tie (0 W) 43.11 V 13.66% 90.9%
CSI Solar Co Ltd CS6X-265P
CSI Solar Co Ltd
265.0 W Tie (0 W) 43.9 V 14.31% 88.8%
Gintung Energy ASEC-265G6S
Gintung Energy
265.0 W Tie (0 W) 44.12 V 13.55% 89.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Advance Power API-P265?

Evaluate Advance Power API-P265 (265.0 W STC, 43.27 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Advance Power API-P265 reaches 49.77 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 31 panels for an 8 kW build require 651 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (651 sq ft).
  • 2026 tax credit baseline: cash residential installs of Advance Power API-P265 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Advance Power API-P265 8 kW Residential Fit

Needs 31 modules (651 sq ft) with a 15 A string OCPD, offsetting ~$2,055/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Auxin Solar AXN6P610T265.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 236.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Advance Power API-P265 by Advance Power grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Advance Power API-P265 PTC wattage (236.0 W) lower than STC (265.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 236.0 W PTC (89.1% retention) across Advance Power API-P265's 1.951 m2 aperture.

Who should skip Advance Power API-P265 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 31 Advance Power API-P265 panels (651 sq ft) leave unusable roof gaps vs. Auxin Solar AXN6P610T265.

What is the 1,000 V commercial string limit for Advance Power API-P265?

On 1,000 V commercial inverters at -10 C (48.33 V cold Voc), Advance Power API-P265 fits up to 20 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Advance Power API-P265.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.