Auxin Solar AXN6P610T265 — CEC Solar Module Specifications

Manufacturer: Auxin Solar Registry: CEC Verified Engineering Specification

Auxin Solar AXN6P610T265 is a 265.0 W STC (236.0 W PTC) Multi-c-Si solar module ranking #18,880 of 21,677 CEC listings (below all-CEC median; higher than 11.7% of peers). It delivers 13.58% efficiency, 43.27 V Voc at 25 C, and 48.33 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
265.0 W
PTC Wattage
236.0 W
Voc @ 25C
43.27 V
Efficiency
13.58%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Auxin Solar AXN6P610T265 Compare Against Peer CEC Listings?

How Auxin Solar Auxin Solar AXN6P610T265 handles rooftop heat (236.0 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Auxin Solar AXN6P610T265 exhibits 7.95 A short-circuit current, requiring a 12.4 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #18,880 of 21,677 (13.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 60.5 m2 for an 8 kW system (38 panels for 10 kW). Mid-range 43.27 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.

Where Does Auxin Solar AXN6P610T265 Fall Across Listed CEC Models?

Where Auxin Solar AXN6P610T265 (265.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Auxin Solar AXN6P610T265 (265.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAuxin Solar AXN6P6: 265.0 W

What Dataset Percentiles Define Auxin Solar AXN6P610T265?

Percentile placement of Auxin Solar AXN6P610T265 across power density (135.8 W/m2), thermal retention, and nameplate STC wattage.

Auxin Solar AXN6P610T265 Engineering BenchmarksPercentile comparison of Auxin Solar AXN6P610T265 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage265.0 WPTC/STC Retention89.1%Module Efficiency13.58%

What Do the Dataset Ranks Show for Auxin Solar AXN6P610T265?

Four critical engineering numbers homeowners and solar installers check first when reviewing Auxin Solar AXN6P610T265 specifications. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Rank #18,880 / 21,677

265.0 W STC · Higher Than 11.7%

265.0 W STC (-120.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,170

13.58% Aperture Efficiency

Power density 135.8 W/m2 (6.33 percentage points below 19.91% CEC median). PTC/STC ratio: 89.1% (rank #20,440).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 48.33 V at -10 C (580.0 V string) and 49.77 V at -20 C (12 max).

8 kW Reference Array

31 Panels = 8,215 W STC

Occupies 60.5 m2 (651 sq ft) producing 7,316 W PTC; NEC 690.8 OCPD floor is 12.4 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.27 * (1 + (-0.334/100) * (-10 - 25)) = 48.33 V | OCPD = 1.56 * 7.95 = 12.4 A

Inputs from CEC Modules.csv for Auxin Solar AXN6P610T265: Voc=43.27 V, beta_Voc=-0.334%/C, Isc=7.95 A, STC=265.0 W, Area=1.951 m2.

Result: 12 panels max on 600 V (580.0 V); 31 panels for 8 kW (651 sq ft).

What Are the Published CEC Specifications for Auxin Solar AXN6P610T265?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Auxin Solar AXN6P610T265.

Official California Energy Commission (NREL SAM) test parameters for Auxin Solar AXN6P610T265.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 265.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 236.0 W (89.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 43.27 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 7.95 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.14 V / 7.33 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.334 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.58% (1.951 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Auxin Solar AXN6P610T265 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Auxin Solar AXN6P610T265 (265.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 23 6.09 kW 483 sq ft $1,524 $2,577
8 kW Class 31 8.21 kW 651 sq ft $2,055 $3,475
10 kW Class 38 10.07 kW 798 sq ft $2,520 $4,262

Which Sibling Wattage & Trim Variants Belong to This Auxin Solar Series?

All closely matched Auxin Solar wattages and cosmetic trims sharing the Auxin Solar AXN6P610T265 architecture. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the Auxin Solar AXN6P610T265 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Auxin Solar AXN6P610T260 260.0 W 231.5 W 43.2 V 35.93 V 13.33%
Auxin Solar AXN6P610T265 265.0 W 236.0 W 43.27 V 36.14 V 13.58%

How Many Auxin Solar AXN6P610T265 Modules Fit in a Cold-Weather String?

Maximum series module counts for Auxin Solar AXN6P610T265 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=43.27V and beta_Voc=-0.334%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 49.77 V 12 panels 597.2 V 20 panels
-10 C (14 F) 48.33 V 12 panels 580.0 V 20 panels
0 C (32 F) 46.88 V 12 panels 562.6 V 21 panels
25 C (77 F STC) 43.27 V 13 panels 562.5 V 23 panels

Which Cross-Brand Solar Modules Compare Closest to Auxin Solar AXN6P610T265?

Alternative CEC solar modules from competing brands near Auxin Solar AXN6P610T265 (265.0 W), including Advance Power API-P265. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Advance Power API-P265
Advance Power
265.0 W Tie (0 W) 43.27 V 13.58% 89.1%
BYD Company Limited BYD 265P6C-36
BYD Company Limited
265.0 W Tie (0 W) 43.11 V 13.66% 90.9%
CSI Solar Co Ltd CS6X-265P
CSI Solar Co Ltd
265.0 W Tie (0 W) 43.9 V 14.31% 88.8%
Gintung Energy ASEC-265G6S
Gintung Energy
265.0 W Tie (0 W) 44.12 V 13.55% 89.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Auxin Solar AXN6P610T265?

Evaluate Auxin Solar AXN6P610T265 (265.0 W STC, 43.27 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Auxin Solar AXN6P610T265 reaches 49.77 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 31 panels for an 8 kW build require 651 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (651 sq ft).
  • 2026 tax credit baseline: cash residential installs of Auxin Solar AXN6P610T265 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Auxin Solar AXN6P610T265 8 kW Residential Fit

Needs 31 modules (651 sq ft) with a 15 A string OCPD, offsetting ~$2,055/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Advance Power API-P265.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 236.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Auxin Solar AXN6P610T265 by Auxin Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Auxin Solar AXN6P610T265 PTC wattage (236.0 W) lower than STC (265.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 236.0 W PTC (89.1% retention) across Auxin Solar AXN6P610T265's 1.951 m2 aperture.

Who should skip Auxin Solar AXN6P610T265 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 31 Auxin Solar AXN6P610T265 panels (651 sq ft) leave unusable roof gaps vs. Advance Power API-P265.

What is the 1,000 V commercial string limit for Auxin Solar AXN6P610T265?

On 1,000 V commercial inverters at -10 C (48.33 V cold Voc), Auxin Solar AXN6P610T265 fits up to 20 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Auxin Solar AXN6P610T265.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?