Manufacturer: Heliene Registry: CEC Verified Engineering Specification

Heliene 96M395 is a 395.0 W STC (352.5 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 15.35% efficiency, 59.5 V Voc at 25 C, and 67.08 V cold Voc at -10 C (8 panels max per 600 V string).

STC Wattage
395.0 W
PTC Wattage
352.5 W
Voc @ 25C
59.5 V
Efficiency
15.35%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Heliene 96M395 Compare Against Peer CEC Listings?

Engineering position of Heliene 96M395 (395.0 W STC) vs. CSI Solar Co Ltd CS1Y-390MS across 5,889 CEC Mono-c-Si solar modules.

Built with 96 Mono-c-Si cells, Heliene 96M395 pairs typical 89.2% PTC-to-STC thermal output (352.5 W real-world rating) with 59.5 V nominal Voc. An 8 kW residential build (8,295 W DC, 7,402 W PTC) saves ~$2,075/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer CSI Solar Co Ltd CS1Y-390MS offers a 390.0 W alternative.

Where Does Heliene 96M395 Fall Across Listed CEC Models?

Plots Heliene 96M395 at 395.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Heliene 96M395 (395.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHeliene 96M395: 395.0 W

What Dataset Percentiles Define Heliene 96M395?

Benchmarks Heliene 96M395 on STC wattage, thermal PTC/STC retention, and 15.35 aperture conversion efficiency against CEC peers.

Heliene 96M395 Engineering BenchmarksPercentile comparison of Heliene 96M395 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage395.0 WPTC/STC Retention89.2%Module Efficiency15.35%

What Do the Dataset Ranks Show for Heliene 96M395?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Heliene 96M395 by Heliene.

Rank #9,869 / 21,677

Top 47.6% STC Output

395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #19,218

15.35% Aperture Efficiency

Power density 153.5 W/m2 (4.56 percentage points below 19.91% CEC median). PTC/STC ratio: 89.2% (rank #20,311).

NEC 690.7 Limit

8 Panels Max @ -10 C (600 V)

Cold Voc reaches 67.08 V at -10 C (536.6 V string) and 69.25 V at -20 C (8 max).

8 kW Reference Array

21 Panels = 8,295 W STC

Occupies 54.1 m2 (582 sq ft) producing 7,402 W PTC; NEC 690.8 OCPD floor is 13.53 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 59.5 * (1 + (-0.364/100) * (-10 - 25)) = 67.08 V | OCPD = 1.56 * 8.67 = 13.53 A

Inputs from CEC Modules.csv for Heliene 96M395: Voc=59.5 V, beta_Voc=-0.364%/C, Isc=8.67 A, STC=395.0 W, Area=2.574 m2.

Result: 8 panels max on 600 V (536.6 V); 21 panels for 8 kW (582 sq ft).

What Are the Published CEC Specifications for Heliene 96M395?

Laboratory test ratings recorded for Heliene 96M395 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Heliene 96M395.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 395.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 352.5 W (89.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 59.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.67 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 48.17 V / 8.2 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.364 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.35% (2.574 m2) Array roof footprint density
Cell Count & Technology 96 cells (Mono-c-Si) Monofacial backsheet

How Many Heliene 96M395 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (582 sq ft at 8 kW), and estimated Year-1 electric bill offset for Heliene 96M395.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.32 kW 443 sq ft $1,582 $2,675
8 kW Class 21 8.29 kW 582 sq ft $2,075 $3,509
10 kW Class 26 10.27 kW 720 sq ft $2,570 $4,347

Which Sibling Wattage & Trim Variants Belong to This Heliene Series?

Sibling wattage bins and frame colors grouped with Heliene 96M395 under Heliene to prevent duplicate spec pages. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sibling CEC listings grouped into the Heliene 96M395 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Heliene 96M390 390.0 W 347.9 W 59.3 V 47.91 V 15.15%
Heliene 96M395 395.0 W 352.5 W 59.5 V 48.17 V 15.35%

How Many Heliene 96M395 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Heliene 96M395 (beta_Voc -0.364%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=59.5V and beta_Voc=-0.364%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 69.25 V 8 panels 554.0 V 14 panels
-10 C (14 F) 67.08 V 8 panels 536.6 V 14 panels
0 C (32 F) 64.91 V 9 panels 584.2 V 15 panels
25 C (77 F STC) 59.5 V 10 panels 595.0 V 16 panels

Which Cross-Brand Solar Modules Compare Closest to Heliene 96M395?

Closest cross-brand CEC competitors to Heliene 96M395 matched near 395.0 W STC and 59.5 V Voc, led by CSI Solar Co Ltd CS1Y-390MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS1Y-390MS
CSI Solar Co Ltd
390.0 W -5.0 W 51.9 V 20.0% 94.0%
BYD Company Limited BYD415MIK-36
BYD Company Limited
395.0 W Tie (0 W) 50.06 V 19.65% 93.9%
ELITE Solar ET-M672BH395GL
ELITE Solar
395.0 W Tie (0 W) 49.6 V 19.36% 93.2%
ELITE Solar ET-M672BH395WW
ELITE Solar
395.0 W Tie (0 W) 49.5 V 19.85% 93.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Heliene 96M395?

Evaluate Heliene 96M395 (395.0 W STC, 59.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Heliene 96M395 reaches 69.25 V per panel—exceeding 8 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 582 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (582 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Heliene 96M395 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Heliene 96M395 8 kW Residential Fit

Needs 21 modules (582 sq ft) with a 15 A string OCPD, offsetting ~$2,075/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 8 panels (-10 C) or 8 panels (-20 C), or compare CSI Solar Co Ltd CS1Y-390MS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 352.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Heliene 96M395 by Heliene grounded in CEC test data and NEC 690.7/690.8 limits. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

What fuse or breaker size does NEC 690.8 require for Heliene 96M395?

Multiplying Heliene 96M395's 8.67 A short-circuit current by 1.56 equals 13.53 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for Heliene 96M395 before finalizing component orders.

Can Heliene 96M395 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 67.08 V cold Voc at 14 F and handles 8.67 A Isc; string inverters cap Heliene 96M395 at 8 panels on 600 V.

Is Heliene 96M395 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Heliene 96M395 rely on utility bill offset (~$2,075/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?