Heliene 60M240 is a 240.0 W STC (216.3 W PTC) Mono-c-Si solar module ranking #20,160 of 21,677 CEC listings (below all-CEC median; higher than 6.1% of peers). It delivers 14.43% efficiency, 36.8 V Voc at 25 C, and 40.86 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 240.0 W
- PTC Wattage
- 216.3 W
- Voc @ 25C
- 36.8 V
- Efficiency
- 14.43%
How Does Heliene 60M240 Compare Against Peer CEC Listings?
Engineering position of Heliene 60M240 (240.0 W STC) vs. Centrosolar America DM60 240 across 5,889 CEC Mono-c-Si solar modules.
Ranking #20,160 across 21,677 CEC solar panels (below all-CEC median; higher than 6.1% of peers), Heliene 60M240 operates as a compact residential or specialty off-grid module sitting 170.0 W below the 410.0 W Mono-c-Si median. Lower 36.8 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters. With typical 90.1% PTC-to-STC thermal output (216.3 W real-world rating), 34 panels occupy 609 sq ft and offset roughly $2,042/yr at average US rates (or $3,454/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Heliene 60M240 Fall Across Listed CEC Models?
Plots Heliene 60M240 at 240.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Heliene 60M240?
Benchmarks Heliene 60M240 on STC wattage, thermal PTC/STC retention, and 14.43 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Heliene 60M240?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Heliene 60M240 by Heliene.
240.0 W STC · Higher Than 6.1%
240.0 W STC (-145.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
14.43% Aperture Efficiency
Power density 144.3 W/m2 (5.48 percentage points below 19.91% CEC median). PTC/STC ratio: 90.1% (rank #18,772).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.86 V at -10 C (572.0 V string) and 42.02 V at -20 C (14 max).
34 Panels = 8,160 W STC
Occupies 56.5 m2 (609 sq ft) producing 7,354 W PTC; NEC 690.8 OCPD floor is 13.57 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.8 * (1 + (-0.315/100) * (-10 - 25)) = 40.86 V | OCPD = 1.56 * 8.7 = 13.57 A
Inputs from CEC Modules.csv for Heliene 60M240: Voc=36.8 V, beta_Voc=-0.315%/C, Isc=8.7 A, STC=240.0 W, Area=1.663 m2.
Result: 14 panels max on 600 V (572.0 V); 34 panels for 8 kW (609 sq ft).
What Are the Published CEC Specifications for Heliene 60M240?
Laboratory test ratings recorded for Heliene 60M240 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 240.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 216.3 W (90.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.7 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.0 V / 8.0 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.315 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.43% (1.663 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Heliene 60M240 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (609 sq ft at 8 kW), and estimated Year-1 electric bill offset for Heliene 60M240.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 25 | 6.0 kW | 448 sq ft | $1,502 | $2,539 |
| 8 kW Class | 34 | 8.16 kW | 609 sq ft | $2,042 | $3,454 |
| 10 kW Class | 42 | 10.08 kW | 752 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Heliene Series?
Sibling wattage bins and frame colors grouped with Heliene 60M240 under Heliene to prevent duplicate spec pages. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Heliene 60M230 | 230.0 W | 207.1 W | 36.6 V | 29.5 V | 13.83% |
| Heliene 60M235 | 235.0 W | 211.7 W | 36.7 V | 29.75 V | 14.13% |
| Heliene 60M240 | 240.0 W | 216.3 W | 36.8 V | 30.0 V | 14.43% |
| Heliene 60M245 | 245.0 W | 220.9 W | 37.26 V | 30.03 V | 14.73% |
How Many Heliene 60M240 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Heliene 60M240 (beta_Voc -0.315%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.02 V | 14 panels | 588.3 V | 23 panels |
| -10 C (14 F) | 40.86 V | 14 panels | 572.0 V | 24 panels |
| 0 C (32 F) | 39.7 V | 15 panels | 595.5 V | 25 panels |
| 25 C (77 F STC) | 36.8 V | 16 panels | 588.8 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to Heliene 60M240?
Closest cross-brand CEC competitors to Heliene 60M240 matched near 240.0 W STC and 36.8 V Voc, led by Centrosolar America DM60 240.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Centrosolar America DM60 240 Centrosolar America |
240.0 W | Tie (0 W) | 36.8 V | 14.64% | 90.6% |
| Eoplly New Energy Technology EP156M/60-240S AC Eoplly New Energy Technology |
240.0 W | Tie (0 W) | 36.9 V | 14.83% | 89.7% |
| Eoplly New Energy Technology EP156MB/60-240S AC Eoplly New Energy Technology |
240.0 W | Tie (0 W) | 36.9 V | 14.83% | 89.5% |
| Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-0-240T Hanwha Qcells (Qidong) Co Ltd |
240.0 W | Tie (0 W) | 37.1 V | 14.53% | 88.9% |
What Are the Design Limits and Best-Fit Uses for Heliene 60M240?
Evaluate Heliene 60M240 (240.0 W STC, 36.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Heliene 60M240 reaches 42.02 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 34 panels for an 8 kW build require 609 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (609 sq ft).
- 2026 tax credit baseline: cash residential installs of Heliene 60M240 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Heliene 60M240 8 kW Residential Fit
Needs 34 modules (609 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Centrosolar America DM60 240.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 216.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Heliene 60M240 by Heliene grounded in CEC test data and NEC 690.7/690.8 limits. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
How many Heliene 60M240 panels fit on a 600 V winter solar string?
At -10 C (14 F), Heliene 60M240 cold Voc rises from 36.8 V to 40.86 V (beta_Voc -0.315%/C), capping a 600 V string at 14 panels (572.0 V).
How much roof area does an 8 kW array of Heliene 60M240 need?
An 8 kW DC system uses 34 Heliene 60M240 modules (8,160 W STC / 7,354 W PTC), covering roughly 609 sq ft and saving ~$2,042/yr at 18.54 c/kWh.
How does Heliene 60M240 compare against Centrosolar America DM60 240?
Heliene 60M240 outputs 240.0 W STC (36.8 V Voc, rank #20,160 of 21,677), while Centrosolar America DM60 240 delivers 240.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)