Centrosolar America DM60 240 — CEC Solar Module Specifications

Manufacturer: Centrosolar America Registry: CEC Verified Engineering Specification

Centrosolar America DM60 240 is a 240.0 W STC (217.4 W PTC) Mono-c-Si solar module ranking #20,160 of 21,677 CEC listings (below all-CEC median; higher than 6.1% of peers). It delivers 14.64% efficiency, 36.8 V Voc at 25 C, and 40.97 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
240.0 W
PTC Wattage
217.4 W
Voc @ 25C
36.8 V
Efficiency
14.64%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Centrosolar America DM60 240 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Centrosolar America DM60 240 (Mono-c-Si) residential solar systems.

Homeowners evaluating Centrosolar America DM60 240 need 25 panels for 6 kW or 34 panels (600 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (600 sq ft). Under NEC 690.7(A), beta_Voc (-0.324%/C) pushes open-circuit voltage to 40.97 V at 14 F and 42.17 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Centrosolar America DM60 240 Fall Across Listed CEC Models?

Comparison of Centrosolar America DM60 240 (240.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Centrosolar America DM60 240 (240.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCentrosolar Americ: 240.0 W

What Dataset Percentiles Define Centrosolar America DM60 240?

Relative ranking of Centrosolar America DM60 240 across nameplate watts, 90.6% PTC thermal ratio, and module aperture efficiency.

Centrosolar America DM60 240 Engineering BenchmarksPercentile comparison of Centrosolar America DM60 240 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage240.0 WPTC/STC Retention90.6%Module Efficiency14.64%

What Do the Dataset Ranks Show for Centrosolar America DM60 240?

Summary of Centrosolar America DM60 240 output rank, 8 kW array size (34 panels), efficiency rating, and 600 V string limit.

Rank #20,160 / 21,677

240.0 W STC · Higher Than 6.1%

240.0 W STC (-145.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #20,260

14.64% Aperture Efficiency

Power density 146.3 W/m2 (5.27 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.97 V at -10 C (573.6 V string) and 42.17 V at -20 C (14 max).

8 kW Reference Array

34 Panels = 8,160 W STC

Occupies 55.8 m2 (600 sq ft) producing 7,392 W PTC; NEC 690.8 OCPD floor is 13.42 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.8 * (1 + (-0.324/100) * (-10 - 25)) = 40.97 V | OCPD = 1.56 * 8.6 = 13.42 A

Inputs from CEC Modules.csv for Centrosolar America DM60 240: Voc=36.8 V, beta_Voc=-0.324%/C, Isc=8.6 A, STC=240.0 W, Area=1.64 m2.

Result: 14 panels max on 600 V (573.6 V); 34 panels for 8 kW (600 sq ft).

What Are the Published CEC Specifications for Centrosolar America DM60 240?

Complete CEC test sheet for Centrosolar America DM60 240 including Isc (8.6 A), Voc (36.8 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Centrosolar America DM60 240.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 240.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 217.4 W (90.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 36.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.6 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 29.7 V / 8.1 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.324 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.64% (1.64 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Centrosolar America DM60 240 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Centrosolar America DM60 240.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 25 6.0 kW 441 sq ft $1,502 $2,539
8 kW Class 34 8.16 kW 600 sq ft $2,042 $3,454
10 kW Class 42 10.08 kW 741 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This Centrosolar America Series?

Related Centrosolar America power steps and black/silver trims consolidated into this Centrosolar America DM60 240 series guide.

Sibling CEC listings grouped into the Centrosolar America DM60 240 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Centrosolar America DM60 230 230.0 W 208.1 W 36.2 V 28.8 V 14.03%
Centrosolar America DM60 235 235.0 W 212.8 W 36.5 V 29.4 V 14.33%
Centrosolar America DM60 240 240.0 W 217.4 W 36.8 V 29.7 V 14.64%
Centrosolar America DM60 245 245.0 W 222.0 W 37.1 V 30.3 V 14.94%

How Many Centrosolar America DM60 240 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Centrosolar America DM60 240 (36.8 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=36.8V and beta_Voc=-0.324%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.17 V 14 panels 590.4 V 23 panels
-10 C (14 F) 40.97 V 14 panels 573.6 V 24 panels
0 C (32 F) 39.78 V 15 panels 596.7 V 25 panels
25 C (77 F STC) 36.8 V 16 panels 588.8 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to Centrosolar America DM60 240?

Four comparable CEC modules such as Heliene 60M240 (240.0 W) for side-by-side solar quote checks. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Heliene 60M240
Heliene
240.0 W Tie (0 W) 36.8 V 14.43% 90.1%
Eoplly New Energy Technology EP156M/60-240S AC
Eoplly New Energy Technology
240.0 W Tie (0 W) 36.9 V 14.83% 89.7%
Eoplly New Energy Technology EP156MB/60-240S AC
Eoplly New Energy Technology
240.0 W Tie (0 W) 36.9 V 14.83% 89.5%
Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-0-240T
Hanwha Qcells (Qidong) Co Ltd
240.0 W Tie (0 W) 37.1 V 14.53% 88.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Centrosolar America DM60 240?

Evaluate Centrosolar America DM60 240 (240.0 W STC, 36.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Centrosolar America DM60 240 reaches 42.17 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 34 panels for an 8 kW build require 600 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (600 sq ft).
  • 2026 tax credit baseline: cash residential installs of Centrosolar America DM60 240 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Centrosolar America DM60 240 8 kW Residential Fit

Needs 34 modules (600 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Heliene 60M240.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 217.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Centrosolar America DM60 240 by Centrosolar America grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Centrosolar America DM60 240 PTC wattage (217.4 W) lower than STC (240.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 217.4 W PTC (90.6% retention) across Centrosolar America DM60 240's 1.64 m2 aperture.

Who should skip Centrosolar America DM60 240 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 34 Centrosolar America DM60 240 panels (600 sq ft) leave unusable roof gaps vs. Heliene 60M240.

What is the 1,000 V commercial string limit for Centrosolar America DM60 240?

On 1,000 V commercial inverters at -10 C (40.97 V cold Voc), Centrosolar America DM60 240 fits up to 24 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Centrosolar America DM60 240.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.