Eoplly New Energy Technology EP156M/60-240S AC is a 240.0 W STC (215.3 W PTC) Mono-c-Si solar module ranking #20,160 of 21,677 CEC listings (below all-CEC median; higher than 6.1% of peers). It delivers 14.83% efficiency, 36.9 V Voc at 25 C, and 41.29 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 240.0 W
- PTC Wattage
- 215.3 W
- Voc @ 25C
- 36.9 V
- Efficiency
- 14.83%
How Does Eoplly New Energy Technology EP156M/60-240S AC Compare Against Peer CEC Listings?
How Eoplly New Energy Technology Eoplly New Energy Technology EP156M/60-240S AC handles rooftop heat (215.3 W PTC), 8 kW sizing, and cold winter string voltage.
Eoplly New Energy Technology builds the Eoplly New Energy Technology EP156M/60-240S AC (Mono-c-Si) as a compact residential or specialty off-grid module delivering 148.3 W/m2 (5.08 percentage points below 19.91% CEC median). Compared against Centrosolar America DM60 240 (240.0 W), this model holds typical 89.7% PTC-to-STC thermal output (215.3 W real-world rating). Lower 36.9 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 13.54 A overcurrent floor served by a 15 A breaker.
Where Does Eoplly New Energy Technology EP156M/60-240S AC Fall Across Listed CEC Models?
Where Eoplly New Energy Technology EP156M/60-240S AC (240.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Eoplly New Energy Technology EP156M/60-240S AC?
Percentile placement of Eoplly New Energy Technology EP156M/60-240S AC across power density (148.3 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Eoplly New Energy Technology EP156M/60-240S AC?
Four critical engineering numbers homeowners and solar installers check first when reviewing Eoplly New Energy Technology EP156M/60-240S AC specifications.
240.0 W STC · Higher Than 6.1%
240.0 W STC (-145.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
14.83% Aperture Efficiency
Power density 148.3 W/m2 (5.08 percentage points below 19.91% CEC median). PTC/STC ratio: 89.7% (rank #19,653).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.29 V at -10 C (578.1 V string) and 42.55 V at -20 C (14 max).
34 Panels = 8,160 W STC
Occupies 55.0 m2 (592 sq ft) producing 7,320 W PTC; NEC 690.8 OCPD floor is 13.54 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.9 * (1 + (-0.34/100) * (-10 - 25)) = 41.29 V | OCPD = 1.56 * 8.68 = 13.54 A
Inputs from CEC Modules.csv for Eoplly New Energy Technology EP156M/60-240S AC: Voc=36.9 V, beta_Voc=-0.34%/C, Isc=8.68 A, STC=240.0 W, Area=1.618 m2.
Result: 14 panels max on 600 V (578.1 V); 34 panels for 8 kW (592 sq ft).
What Are the Published CEC Specifications for Eoplly New Energy Technology EP156M/60-240S AC?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Eoplly New Energy Technology EP156M/60-240S AC.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 240.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 215.3 W (89.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.68 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.01 V / 8.01 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.34 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.83% (1.618 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Eoplly New Energy Technology EP156M/60-240S AC Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Eoplly New Energy Technology EP156M/60-240S AC (240.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 25 | 6.0 kW | 435 sq ft | $1,502 | $2,539 |
| 8 kW Class | 34 | 8.16 kW | 592 sq ft | $2,042 | $3,454 |
| 10 kW Class | 42 | 10.08 kW | 731 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Eoplly New Energy Technology Series?
All closely matched Eoplly New Energy Technology wattages and cosmetic trims sharing the Eoplly New Energy Technology EP156M/60-240S AC architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Eoplly New Energy Technology EP156M/60-230S AC | 230.0 W | 205.5 W | 36.55 V | 29.24 V | 14.21% |
| Eoplly New Energy Technology EP156M/60-235S AC | 235.0 W | 210.1 W | 36.72 V | 29.6 V | 14.52% |
| Eoplly New Energy Technology EP156M/60-240S AC | 240.0 W | 215.3 W | 36.9 V | 30.01 V | 14.83% |
| Eoplly New Energy Technology EP156M/60-245S AC | 245.0 W | 219.9 W | 37.08 V | 30.42 V | 15.14% |
How Many Eoplly New Energy Technology EP156M/60-240S AC Modules Fit in a Cold-Weather String?
Maximum series module counts for Eoplly New Energy Technology EP156M/60-240S AC from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.55 V | 14 panels | 595.7 V | 23 panels |
| -10 C (14 F) | 41.29 V | 14 panels | 578.1 V | 24 panels |
| 0 C (32 F) | 40.04 V | 14 panels | 560.6 V | 24 panels |
| 25 C (77 F STC) | 36.9 V | 16 panels | 590.4 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to Eoplly New Energy Technology EP156M/60-240S AC?
Alternative CEC solar modules from competing brands near Eoplly New Energy Technology EP156M/60-240S AC (240.0 W), including Centrosolar America DM60 240.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Centrosolar America DM60 240 Centrosolar America |
240.0 W | Tie (0 W) | 36.8 V | 14.64% | 90.6% |
| Heliene 60M240 Heliene |
240.0 W | Tie (0 W) | 36.8 V | 14.43% | 90.1% |
| Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-0-240T Hanwha Qcells (Qidong) Co Ltd |
240.0 W | Tie (0 W) | 37.1 V | 14.53% | 88.9% |
| Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-0-240TB Hanwha Qcells (Qidong) Co Ltd |
240.0 W | Tie (0 W) | 37.1 V | 14.53% | 90.0% |
What Are the Design Limits and Best-Fit Uses for Eoplly New Energy Technology EP156M/60-240S AC?
Evaluate Eoplly New Energy Technology EP156M/60-240S AC (240.0 W STC, 36.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Eoplly New Energy Technology EP156M/60-240S AC reaches 42.55 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 34 panels for an 8 kW build require 592 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (592 sq ft).
- 2026 tax credit baseline: cash residential installs of Eoplly New Energy Technology EP156M/60-240S AC carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Eoplly New Energy Technology EP156M/60-240S AC 8 kW Residential Fit
Needs 34 modules (592 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Centrosolar America DM60 240.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 215.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Eoplly New Energy Technology EP156M/60-240S AC by Eoplly New Energy Technology grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Eoplly New Energy Technology EP156M/60-240S AC?
Multiplying Eoplly New Energy Technology EP156M/60-240S AC's 8.68 A short-circuit current by 1.56 equals 13.54 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Eoplly New Energy Technology EP156M/60-240S AC pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 41.29 V cold Voc at 14 F and handles 8.68 A Isc; string inverters cap Eoplly New Energy Technology EP156M/60-240S AC at 14 panels on 600 V.
Is Eoplly New Energy Technology EP156M/60-240S AC eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Eoplly New Energy Technology EP156M/60-240S AC rely on utility bill offset (~$2,042/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)