Skip to main content
WireAndSun
Calculators
CEC PV Module

Eoplly New Energy Technology EP156P/60-255S AC — CEC Solar Module Specifications

Manufacturer: Eoplly New Energy Technology Registry: CEC Verified Engineering Specification

Eoplly New Energy Technology EP156P/60-255S AC is a 255.0 W STC (229.2 W PTC) Multi-c-Si solar module ranking #19,421 of 21,677 CEC listings (below all-CEC median; higher than 9.2% of peers). It delivers 15.6% efficiency, 37.68 V Voc at 25 C, and 42.03 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
255.0 W
PTC Wattage
229.2 W
Voc @ 25C
37.68 V
Efficiency
15.6%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Eoplly New Energy Technology EP156P/60-255S AC Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Eoplly New Energy Technology EP156P/60-255S AC (Multi-c-Si) residential solar systems.

Homeowners evaluating Eoplly New Energy Technology EP156P/60-255S AC need 24 panels for 6 kW or 32 panels (563 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 32 panels (563 sq ft). Under NEC 690.7(A), beta_Voc (-0.33%/C) pushes open-circuit voltage to 42.03 V at 14 F and 43.28 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Eoplly New Energy Technology EP156P/60-255S AC Fall Across Listed CEC Models?

Comparison of Eoplly New Energy Technology EP156P/60-255S AC (255.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Eoplly New Energy Technology EP156P/60-255S AC (255.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCEoplly New Energy : 255.0 W

What Dataset Percentiles Define Eoplly New Energy Technology EP156P/60-255S AC?

Relative ranking of Eoplly New Energy Technology EP156P/60-255S AC across nameplate watts, 89.9% PTC thermal ratio, and module aperture efficiency.

Eoplly New Energy Technology EP156P/60-255S AC Engineering BenchmarksPercentile comparison of Eoplly New Energy Technology EP156P/60-255S AC wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage255.0 WPTC/STC Retention89.9%Module Efficiency15.6%

What Do the Dataset Ranks Show for Eoplly New Energy Technology EP156P/60-255S AC?

Summary of Eoplly New Energy Technology EP156P/60-255S AC output rank, 8 kW array size (32 panels), efficiency rating, and 600 V string limit.

Rank #19,421 / 21,677

255.0 W STC · Higher Than 9.2%

255.0 W STC (-130.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,797

15.6% Aperture Efficiency

Power density 156.1 W/m2 (4.31 percentage points below 19.91% CEC median). PTC/STC ratio: 89.9% (rank #19,247).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.03 V at -10 C (588.4 V string) and 43.28 V at -20 C (13 max).

8 kW Reference Array

32 Panels = 8,160 W STC

Occupies 52.3 m2 (563 sq ft) producing 7,334 W PTC; NEC 690.8 OCPD floor is 13.88 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.68 * (1 + (-0.33/100) * (-10 - 25)) = 42.03 V | OCPD = 1.56 * 8.9 = 13.88 A

Inputs from CEC Modules.csv for Eoplly New Energy Technology EP156P/60-255S AC: Voc=37.68 V, beta_Voc=-0.33%/C, Isc=8.9 A, STC=255.0 W, Area=1.634 m2.

Result: 14 panels max on 600 V (588.4 V); 32 panels for 8 kW (563 sq ft).

What Are the Published CEC Specifications for Eoplly New Energy Technology EP156P/60-255S AC?

Complete CEC test sheet for Eoplly New Energy Technology EP156P/60-255S AC including Isc (8.9 A), Voc (37.68 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Eoplly New Energy Technology EP156P/60-255S AC.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 255.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 229.2 W (89.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.68 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.9 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.56 V / 8.1 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.33 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.6% (1.634 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Eoplly New Energy Technology EP156P/60-255S AC Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Eoplly New Energy Technology EP156P/60-255S AC.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 24 6.12 kW 422 sq ft $1,532 $2,590
8 kW Class 32 8.16 kW 563 sq ft $2,042 $3,454
10 kW Class 40 10.2 kW 704 sq ft $2,553 $4,317

Which Sibling Wattage & Trim Variants Belong to This Eoplly New Energy Technology Series?

Related Eoplly New Energy Technology power steps and black/silver trims consolidated into this Eoplly New Energy Technology EP156P/60-255S AC series guide.

Sibling CEC listings grouped into the Eoplly New Energy Technology EP156P/60-255S AC wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Eoplly New Energy Technology EP156P/60-250S AC 250.0 W 224.6 W 37.56 V 31.32 V 15.3%
Eoplly New Energy Technology EP156P/60-255S AC 255.0 W 229.2 W 37.68 V 31.56 V 15.6%
Eoplly New Energy Technology EP156P/60-260S AC 260.0 W 233.8 W 37.8 V 31.8 V 15.91%

How Many Eoplly New Energy Technology EP156P/60-255S AC Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Eoplly New Energy Technology EP156P/60-255S AC (37.68 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=37.68V and beta_Voc=-0.33%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.28 V 13 panels 562.6 V 23 panels
-10 C (14 F) 42.03 V 14 panels 588.4 V 23 panels
0 C (32 F) 40.79 V 14 panels 571.1 V 24 panels
25 C (77 F STC) 37.68 V 15 panels 565.2 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Eoplly New Energy Technology EP156P/60-255S AC?

Four comparable CEC modules such as Advance Power API-M255 (255.0 W) for side-by-side solar quote checks. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Advance Power API-M255
Advance Power
255.0 W Tie (0 W) 37.68 V 15.57% 89.5%
GCL System Integration Technology Co Ltd GCL-P6/60255
GCL System Integration Technology Co Ltd
255.0 W Tie (0 W) 37.7 V 15.67% 90.4%
Advance Power API-P255
Advance Power
255.0 W Tie (0 W) 37.5 V 15.57% 89.4%
Auxin Solar AXN6P610T255
Auxin Solar
255.0 W Tie (0 W) 37.5 V 15.57% 89.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Eoplly New Energy Technology EP156P/60-255S AC?

Evaluate Eoplly New Energy Technology EP156P/60-255S AC (255.0 W STC, 37.68 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Eoplly New Energy Technology EP156P/60-255S AC reaches 43.28 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 32 panels for an 8 kW build require 563 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 32 panels (563 sq ft).
  • 2026 tax credit baseline: cash residential installs of Eoplly New Energy Technology EP156P/60-255S AC carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Eoplly New Energy Technology EP156P/60-255S AC 8 kW Residential Fit

Needs 32 modules (563 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Advance Power API-M255.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 229.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Eoplly New Energy Technology EP156P/60-255S AC by Eoplly New Energy Technology grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Eoplly New Energy Technology EP156P/60-255S AC PTC wattage (229.2 W) lower than STC (255.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 229.2 W PTC (89.9% retention) across Eoplly New Energy Technology EP156P/60-255S AC's 1.634 m2 aperture.

Who should skip Eoplly New Energy Technology EP156P/60-255S AC on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 32 Eoplly New Energy Technology EP156P/60-255S AC panels (563 sq ft) leave unusable roof gaps vs. Advance Power API-M255.

What is the 1,000 V commercial string limit for Eoplly New Energy Technology EP156P/60-255S AC?

On 1,000 V commercial inverters at -10 C (42.03 V cold Voc), Eoplly New Energy Technology EP156P/60-255S AC fits up to 23 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.