Manufacturer: Advance Power Registry: CEC Verified Engineering Specification

Advance Power API-P255 is a 255.0 W STC (228.0 W PTC) Multi-c-Si solar module ranking #19,421 of 21,677 CEC listings (below all-CEC median; higher than 9.2% of peers). It delivers 15.57% efficiency, 37.5 V Voc at 25 C, and 41.88 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
255.0 W
PTC Wattage
228.0 W
Voc @ 25C
37.5 V
Efficiency
15.57%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Advance Power API-P255 Compare Against Peer CEC Listings?

Engineering position of Advance Power API-P255 (255.0 W STC) vs. Auxin Solar AXN6P610T255 across 1,407 CEC Multi-c-Si solar modules.

Built with 60 Multi-c-Si cells, Advance Power API-P255 pairs typical 89.4% PTC-to-STC thermal output (228.0 W real-world rating) with 37.5 V nominal Voc. An 8 kW residential build (8,160 W DC, 7,296 W PTC) saves ~$2,042/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Auxin Solar AXN6P610T255 offers a 255.0 W alternative.

Where Does Advance Power API-P255 Fall Across Listed CEC Models?

Plots Advance Power API-P255 at 255.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Advance Power API-P255 (255.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAdvance Power API-: 255.0 W

What Dataset Percentiles Define Advance Power API-P255?

Benchmarks Advance Power API-P255 on STC wattage, thermal PTC/STC retention, and 15.57 aperture conversion efficiency against CEC peers.

Advance Power API-P255 Engineering BenchmarksPercentile comparison of Advance Power API-P255 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage255.0 WPTC/STC Retention89.4%Module Efficiency15.57%

What Do the Dataset Ranks Show for Advance Power API-P255?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Advance Power API-P255 by Advance Power.

Rank #19,421 / 21,677

255.0 W STC · Higher Than 9.2%

255.0 W STC (-130.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,838

15.57% Aperture Efficiency

Power density 155.7 W/m2 (4.34 percentage points below 19.91% CEC median). PTC/STC ratio: 89.4% (rank #20,078).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.88 V at -10 C (586.3 V string) and 43.14 V at -20 C (13 max).

8 kW Reference Array

32 Panels = 8,160 W STC

Occupies 52.4 m2 (564 sq ft) producing 7,296 W PTC; NEC 690.8 OCPD floor is 13.35 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.5 * (1 + (-0.334/100) * (-10 - 25)) = 41.88 V | OCPD = 1.56 * 8.56 = 13.35 A

Inputs from CEC Modules.csv for Advance Power API-P255: Voc=37.5 V, beta_Voc=-0.334%/C, Isc=8.56 A, STC=255.0 W, Area=1.638 m2.

Result: 14 panels max on 600 V (586.3 V); 32 panels for 8 kW (564 sq ft).

What Are the Published CEC Specifications for Advance Power API-P255?

Laboratory test ratings recorded for Advance Power API-P255 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Advance Power API-P255.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 255.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 228.0 W (89.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.56 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.56 V / 8.08 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.334 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.57% (1.638 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Advance Power API-P255 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (564 sq ft at 8 kW), and estimated Year-1 electric bill offset for Advance Power API-P255.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 24 6.12 kW 423 sq ft $1,532 $2,590
8 kW Class 32 8.16 kW 564 sq ft $2,042 $3,454
10 kW Class 40 10.2 kW 705 sq ft $2,553 $4,317

Which Sibling Wattage & Trim Variants Belong to This Advance Power Series?

Sibling wattage bins and frame colors grouped with Advance Power API-P255 under Advance Power to prevent duplicate spec pages.

Sibling CEC listings grouped into the Advance Power API-P255 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Advance Power API-P250 250.0 W 223.4 W 37.2 V 31.2 V 15.26%
Advance Power API-P255 255.0 W 228.0 W 37.5 V 31.56 V 15.57%

How Many Advance Power API-P255 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Advance Power API-P255 (beta_Voc -0.334%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=37.5V and beta_Voc=-0.334%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.14 V 13 panels 560.8 V 23 panels
-10 C (14 F) 41.88 V 14 panels 586.3 V 23 panels
0 C (32 F) 40.63 V 14 panels 568.8 V 24 panels
25 C (77 F STC) 37.5 V 16 panels 600.0 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Advance Power API-P255?

Closest cross-brand CEC competitors to Advance Power API-P255 matched near 255.0 W STC and 37.5 V Voc, led by Auxin Solar AXN6P610T255.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN6P610T255
Auxin Solar
255.0 W Tie (0 W) 37.5 V 15.57% 89.4%
Eoplly New Energy Technology EP156M/60-255 AC
Eoplly New Energy Technology
255.0 W Tie (0 W) 37.56 V 15.76% 89.9%
Eoplly New Energy Technology EP156M/60-255S AC
Eoplly New Energy Technology
255.0 W Tie (0 W) 37.56 V 15.76% 89.9%
Eoplly New Energy Technology EP156P/60-255S AC
Eoplly New Energy Technology
255.0 W Tie (0 W) 37.68 V 15.6% 89.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Advance Power API-P255?

Evaluate Advance Power API-P255 (255.0 W STC, 37.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Advance Power API-P255 reaches 43.14 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 32 panels for an 8 kW build require 564 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 32 panels (564 sq ft).
  • 2026 tax credit baseline: cash residential installs of Advance Power API-P255 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Advance Power API-P255 8 kW Residential Fit

Needs 32 modules (564 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Auxin Solar AXN6P610T255.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 228.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Advance Power API-P255 by Advance Power grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Advance Power API-P255?

Multiplying Advance Power API-P255's 8.56 A short-circuit current by 1.56 equals 13.35 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Advance Power API-P255 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 41.88 V cold Voc at 14 F and handles 8.56 A Isc; string inverters cap Advance Power API-P255 at 14 panels on 600 V.

Is Advance Power API-P255 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Advance Power API-P255 rely on utility bill offset (~$2,042/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.