Eoplly New Energy Technology EP156M/60-255 AC is a 255.0 W STC (229.2 W PTC) Mono-c-Si solar module ranking #19,421 of 21,677 CEC listings (below all-CEC median; higher than 9.2% of peers). It delivers 15.76% efficiency, 37.56 V Voc at 25 C, and 42.03 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 255.0 W
- PTC Wattage
- 229.2 W
- Voc @ 25C
- 37.56 V
- Efficiency
- 15.76%
How Does Eoplly New Energy Technology EP156M/60-255 AC Compare Against Peer CEC Listings?
Engineering position of Eoplly New Energy Technology EP156M/60-255 AC (255.0 W STC) vs. Advance Power API-P255 across 5,889 CEC Mono-c-Si solar modules.
Built with 60 Mono-c-Si cells, Eoplly New Energy Technology EP156M/60-255 AC pairs typical 89.9% PTC-to-STC thermal output (229.2 W real-world rating) with 37.56 V nominal Voc. An 8 kW residential build (8,160 W DC, 7,334 W PTC) saves ~$2,042/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Advance Power API-P255 offers a 255.0 W alternative.
Where Does Eoplly New Energy Technology EP156M/60-255 AC Fall Across Listed CEC Models?
Plots Eoplly New Energy Technology EP156M/60-255 AC at 255.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Eoplly New Energy Technology EP156M/60-255 AC?
Benchmarks Eoplly New Energy Technology EP156M/60-255 AC on STC wattage, thermal PTC/STC retention, and 15.76 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Eoplly New Energy Technology EP156M/60-255 AC?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Eoplly New Energy Technology EP156M/60-255 AC by Eoplly New Energy Technology.
255.0 W STC · Higher Than 9.2%
255.0 W STC (-130.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
15.76% Aperture Efficiency
Power density 157.6 W/m2 (4.15 percentage points below 19.91% CEC median). PTC/STC ratio: 89.9% (rank #19,247).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.03 V at -10 C (588.4 V string) and 43.31 V at -20 C (13 max).
32 Panels = 8,160 W STC
Occupies 51.8 m2 (557 sq ft) producing 7,334 W PTC; NEC 690.8 OCPD floor is 14.01 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.56 * (1 + (-0.34/100) * (-10 - 25)) = 42.03 V | OCPD = 1.56 * 8.98 = 14.01 A
Inputs from CEC Modules.csv for Eoplly New Energy Technology EP156M/60-255 AC: Voc=37.56 V, beta_Voc=-0.34%/C, Isc=8.98 A, STC=255.0 W, Area=1.618 m2.
Result: 14 panels max on 600 V (588.4 V); 32 panels for 8 kW (557 sq ft).
What Are the Published CEC Specifications for Eoplly New Energy Technology EP156M/60-255 AC?
Laboratory test ratings recorded for Eoplly New Energy Technology EP156M/60-255 AC (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 255.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 229.2 W (89.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.56 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.98 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.2 V / 8.22 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.34 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.76% (1.618 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Eoplly New Energy Technology EP156M/60-255 AC Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (557 sq ft at 8 kW), and estimated Year-1 electric bill offset for Eoplly New Energy Technology EP156M/60-255 AC.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 24 | 6.12 kW | 418 sq ft | $1,532 | $2,590 |
| 8 kW Class | 32 | 8.16 kW | 557 sq ft | $2,042 | $3,454 |
| 10 kW Class | 40 | 10.2 kW | 697 sq ft | $2,553 | $4,317 |
Which Sibling Wattage & Trim Variants Belong to This Eoplly New Energy Technology Series?
Sibling wattage bins and frame colors grouped with Eoplly New Energy Technology EP156M/60-255 AC under Eoplly New Energy Technology to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Eoplly New Energy Technology EP156M/60-250 AC | 250.0 W | 224.5 W | 37.26 V | 30.84 V | 15.45% |
| Eoplly New Energy Technology EP156M/60-255 AC | 255.0 W | 229.2 W | 37.56 V | 31.2 V | 15.76% |
| Eoplly New Energy Technology EP156M/60-260 AC | 260.0 W | 233.8 W | 37.74 V | 31.62 V | 16.07% |
How Many Eoplly New Energy Technology EP156M/60-255 AC Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Eoplly New Energy Technology EP156M/60-255 AC (beta_Voc -0.34%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.31 V | 13 panels | 563.0 V | 23 panels |
| -10 C (14 F) | 42.03 V | 14 panels | 588.4 V | 23 panels |
| 0 C (32 F) | 40.75 V | 14 panels | 570.5 V | 24 panels |
| 25 C (77 F STC) | 37.56 V | 15 panels | 563.4 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Eoplly New Energy Technology EP156M/60-255 AC?
Closest cross-brand CEC competitors to Eoplly New Energy Technology EP156M/60-255 AC matched near 255.0 W STC and 37.56 V Voc, led by Advance Power API-P255.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Advance Power API-P255 Advance Power |
255.0 W | Tie (0 W) | 37.5 V | 15.57% | 89.4% |
| Auxin Solar AXN6P610T255 Auxin Solar |
255.0 W | Tie (0 W) | 37.5 V | 15.57% | 89.4% |
| Advance Power API-M255 Advance Power |
255.0 W | Tie (0 W) | 37.68 V | 15.57% | 89.5% |
| GCL System Integration Technology Co Ltd GCL-P6/60255 GCL System Integration Technology Co Ltd |
255.0 W | Tie (0 W) | 37.7 V | 15.67% | 90.4% |
What Are the Design Limits and Best-Fit Uses for Eoplly New Energy Technology EP156M/60-255 AC?
Evaluate Eoplly New Energy Technology EP156M/60-255 AC (255.0 W STC, 37.56 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Eoplly New Energy Technology EP156M/60-255 AC reaches 43.31 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 32 panels for an 8 kW build require 557 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 32 panels (557 sq ft).
- 2026 tax credit baseline: cash residential installs of Eoplly New Energy Technology EP156M/60-255 AC carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Eoplly New Energy Technology EP156M/60-255 AC 8 kW Residential Fit
Needs 32 modules (557 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Advance Power API-P255.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 229.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Eoplly New Energy Technology EP156M/60-255 AC by Eoplly New Energy Technology grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Eoplly New Energy Technology EP156M/60-255 AC?
Multiplying Eoplly New Energy Technology EP156M/60-255 AC's 8.98 A short-circuit current by 1.56 equals 14.01 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Eoplly New Energy Technology EP156M/60-255 AC pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 42.03 V cold Voc at 14 F and handles 8.98 A Isc; string inverters cap Eoplly New Energy Technology EP156M/60-255 AC at 14 panels on 600 V.
Is Eoplly New Energy Technology EP156M/60-255 AC eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Eoplly New Energy Technology EP156M/60-255 AC rely on utility bill offset (~$2,042/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)