Manufacturer: Eoplly New Energy Technology Registry: CEC Verified Engineering Specification

Eoplly New Energy Technology EP156MB/60-250S AC is a 250.0 W STC (223.9 W PTC) Mono-c-Si solar module ranking #19,686 of 21,677 CEC listings (below all-CEC median; higher than 8.0% of peers). It delivers 15.45% efficiency, 37.26 V Voc at 25 C, and 41.82 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
250.0 W
PTC Wattage
223.9 W
Voc @ 25C
37.26 V
Efficiency
15.45%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Eoplly New Energy Technology EP156MB/60-250S AC Compare Against Peer CEC Listings?

Engineering position of Eoplly New Energy Technology EP156MB/60-250S AC (250.0 W STC) vs. Anji Technology AJP-M660-250 across 5,889 CEC Mono-c-Si solar modules.

Built with 60 Mono-c-Si cells, Eoplly New Energy Technology EP156MB/60-250S AC pairs typical 89.6% PTC-to-STC thermal output (223.9 W real-world rating) with 37.26 V nominal Voc. An 8 kW residential build (8,000 W DC, 7,165 W PTC) saves ~$2,002/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Anji Technology AJP-M660-250 offers a 250.0 W alternative.

Where Does Eoplly New Energy Technology EP156MB/60-250S AC Fall Across Listed CEC Models?

Plots Eoplly New Energy Technology EP156MB/60-250S AC at 250.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Eoplly New Energy Technology EP156MB/60-250S AC (250.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCEoplly New Energy : 250.0 W

What Dataset Percentiles Define Eoplly New Energy Technology EP156MB/60-250S AC?

Benchmarks Eoplly New Energy Technology EP156MB/60-250S AC on STC wattage, thermal PTC/STC retention, and 15.45 aperture conversion efficiency against CEC peers.

Eoplly New Energy Technology EP156MB/60-250S AC Engineering BenchmarksPercentile comparison of Eoplly New Energy Technology EP156MB/60-250S AC wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage250.0 WPTC/STC Retention89.6%Module Efficiency15.45%

What Do the Dataset Ranks Show for Eoplly New Energy Technology EP156MB/60-250S AC?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Eoplly New Energy Technology EP156MB/60-250S AC by Eoplly New Energy Technology.

Rank #19,686 / 21,677

250.0 W STC · Higher Than 8.0%

250.0 W STC (-135.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #19,037

15.45% Aperture Efficiency

Power density 154.5 W/m2 (4.46 percentage points below 19.91% CEC median). PTC/STC ratio: 89.6% (rank #19,798).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.82 V at -10 C (585.5 V string) and 43.13 V at -20 C (13 max).

8 kW Reference Array

32 Panels = 8,000 W STC

Occupies 51.8 m2 (557 sq ft) producing 7,165 W PTC; NEC 690.8 OCPD floor is 13.9 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.26 * (1 + (-0.35/100) * (-10 - 25)) = 41.82 V | OCPD = 1.56 * 8.91 = 13.9 A

Inputs from CEC Modules.csv for Eoplly New Energy Technology EP156MB/60-250S AC: Voc=37.26 V, beta_Voc=-0.35%/C, Isc=8.91 A, STC=250.0 W, Area=1.618 m2.

Result: 14 panels max on 600 V (585.5 V); 32 panels for 8 kW (557 sq ft).

What Are the Published CEC Specifications for Eoplly New Energy Technology EP156MB/60-250S AC?

Laboratory test ratings recorded for Eoplly New Energy Technology EP156MB/60-250S AC (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Eoplly New Energy Technology EP156MB/60-250S AC.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 250.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 223.9 W (89.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.26 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.91 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.84 V / 8.15 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.35 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.45% (1.618 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Eoplly New Energy Technology EP156MB/60-250S AC Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (557 sq ft at 8 kW), and estimated Year-1 electric bill offset for Eoplly New Energy Technology EP156MB/60-250S AC.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 24 6.0 kW 418 sq ft $1,502 $2,539
8 kW Class 32 8.0 kW 557 sq ft $2,002 $3,386
10 kW Class 40 10.0 kW 697 sq ft $2,503 $4,232

How Many Eoplly New Energy Technology EP156MB/60-250S AC Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Eoplly New Energy Technology EP156MB/60-250S AC (beta_Voc -0.35%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=37.26V and beta_Voc=-0.35%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.13 V 13 panels 560.7 V 23 panels
-10 C (14 F) 41.82 V 14 panels 585.5 V 23 panels
0 C (32 F) 40.52 V 14 panels 567.3 V 24 panels
25 C (77 F STC) 37.26 V 16 panels 596.2 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Eoplly New Energy Technology EP156MB/60-250S AC?

Closest cross-brand CEC competitors to Eoplly New Energy Technology EP156MB/60-250S AC matched near 250.0 W STC and 37.26 V Voc, led by Anji Technology AJP-M660-250.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Anji Technology AJP-M660-250
Anji Technology
250.0 W Tie (0 W) 37.32 V 15.4% 89.0%
Boviet Solar Technology Co Ltd BVM6610P-250
Boviet Solar Technology Co Ltd
250.0 W Tie (0 W) 37.5 V 15.37% 90.2%
Changzhou Nesl Solartech DJ-250DA/C-ST15
Changzhou Nesl Solartech
250.0 W Tie (0 W) 38.07 V 15.3% 90.4%
Flextronics FXS-260BB-MAA1B
Flextronics
252.8 W +2.8 W 37.98 V 15.54% 90.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Eoplly New Energy Technology EP156MB/60-250S AC?

Evaluate Eoplly New Energy Technology EP156MB/60-250S AC (250.0 W STC, 37.26 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Eoplly New Energy Technology EP156MB/60-250S AC reaches 43.13 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 32 panels for an 8 kW build require 557 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 32 panels (557 sq ft).
  • 2026 tax credit baseline: cash residential installs of Eoplly New Energy Technology EP156MB/60-250S AC carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Eoplly New Energy Technology EP156MB/60-250S AC 8 kW Residential Fit

Needs 32 modules (557 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Anji Technology AJP-M660-250.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 223.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Eoplly New Energy Technology EP156MB/60-250S AC by Eoplly New Energy Technology grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Eoplly New Energy Technology EP156MB/60-250S AC?

Multiplying Eoplly New Energy Technology EP156MB/60-250S AC's 8.91 A short-circuit current by 1.56 equals 13.9 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Eoplly New Energy Technology EP156MB/60-250S AC pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 41.82 V cold Voc at 14 F and handles 8.91 A Isc; string inverters cap Eoplly New Energy Technology EP156MB/60-250S AC at 14 panels on 600 V.

Is Eoplly New Energy Technology EP156MB/60-250S AC eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Eoplly New Energy Technology EP156MB/60-250S AC rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.