Flextronics FXS-260BB-MAA1B is a 252.8 W STC (229.6 W PTC) Multi-c-Si solar module ranking #19,684 of 21,677 CEC listings (below all-CEC median; higher than 9.2% of peers). It delivers 15.54% efficiency, 37.98 V Voc at 25 C, and 42.74 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 252.8 W
- PTC Wattage
- 229.6 W
- Voc @ 25C
- 37.98 V
- Efficiency
- 15.54%
How Does Flextronics FXS-260BB-MAA1B Compare Against Peer CEC Listings?
Solar engineering breakdown for Flextronics FXS-260BB-MAA1B: PTC thermal retention, roof footprint, and cold Voc string bounds. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
Across 1,407 Multi-c-Si listings from Flextronics and peers, Flextronics FXS-260BB-MAA1B stands 26.0 W below the 278.8 W Multi-c-Si median and typical 90.8% PTC-to-STC thermal output (229.6 W real-world rating). Sizing 6 kW (24 panels) to 10 kW (40 panels) yields $1,519-$2,530/yr in baseline US bill offset. Lower 37.98 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does Flextronics FXS-260BB-MAA1B Fall Across Listed CEC Models?
Distribution marker showing Flextronics FXS-260BB-MAA1B (252.8 W) relative to the 385.0 W all-CEC solar panel median. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
What Dataset Percentiles Define Flextronics FXS-260BB-MAA1B?
Dataset percentiles tracking Flextronics FXS-260BB-MAA1B power output, thermal retention ratio, and aperture efficiency against 21,677 models. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
What Do the Dataset Ranks Show for Flextronics FXS-260BB-MAA1B?
Benchmark highlights for Flextronics FXS-260BB-MAA1B covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
252.8 W STC · Higher Than 9.2%
252.8 W STC (-132.2 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
15.54% Aperture Efficiency
Power density 155.4 W/m2 (4.37 percentage points below 19.91% CEC median). PTC/STC ratio: 90.8% (rank #17,104).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.74 V at -10 C (598.4 V string) and 44.1 V at -20 C (13 max).
32 Panels = 8,090 W STC
Occupies 52.1 m2 (560 sq ft) producing 7,347 W PTC; NEC 690.8 OCPD floor is 13.34 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.98 * (1 + (-0.358/100) * (-10 - 25)) = 42.74 V | OCPD = 1.56 * 8.55 = 13.34 A
Inputs from CEC Modules.csv for Flextronics FXS-260BB-MAA1B: Voc=37.98 V, beta_Voc=-0.358%/C, Isc=8.55 A, STC=252.8 W, Area=1.627 m2.
Result: 14 panels max on 600 V (598.4 V); 32 panels for 8 kW (560 sq ft).
What Are the Published CEC Specifications for Flextronics FXS-260BB-MAA1B?
Official CEC datasheet figures for Flextronics FXS-260BB-MAA1B (Multi-c-Si) used in utility interconnection and permit reviews. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 252.8 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 229.6 W (90.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.98 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.55 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.97 V / 8.16 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.358 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.54% (1.627 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Flextronics FXS-260BB-MAA1B Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Flextronics FXS-260BB-MAA1B modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 24 | 6.07 kW | 420 sq ft | $1,519 | $2,569 |
| 8 kW Class | 32 | 8.09 kW | 560 sq ft | $2,025 | $3,424 |
| 10 kW Class | 40 | 10.11 kW | 701 sq ft | $2,530 | $4,279 |
How Many Flextronics FXS-260BB-MAA1B Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Flextronics FXS-260BB-MAA1B (42.74 V at 14 F). Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.1 V | 13 panels | 573.3 V | 22 panels |
| -10 C (14 F) | 42.74 V | 14 panels | 598.4 V | 23 panels |
| 0 C (32 F) | 41.38 V | 14 panels | 579.3 V | 24 panels |
| 25 C (77 F STC) | 37.98 V | 15 panels | 569.7 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Flextronics FXS-260BB-MAA1B?
Competing CEC solar panels closest to Flextronics FXS-260BB-MAA1B in nameplate wattage and Voc, starting with Changzhou Nesl Solartech DJ-255D/C-ST15.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Changzhou Nesl Solartech DJ-255D/C-ST15 Changzhou Nesl Solartech |
255.0 W | +2.2 W | 38.19 V | 15.61% | 90.4% |
| Changzhou Nesl Solartech DJ-250DA/C-ST15 Changzhou Nesl Solartech |
250.0 W | -2.8 W | 38.07 V | 15.3% | 90.4% |
| GCL System Integration Technology Co Ltd GCL-P6/60255 GCL System Integration Technology Co Ltd |
255.0 W | +2.2 W | 37.7 V | 15.67% | 90.4% |
| Advance Power API-M255 Advance Power |
255.0 W | +2.2 W | 37.68 V | 15.57% | 89.5% |
What Are the Design Limits and Best-Fit Uses for Flextronics FXS-260BB-MAA1B?
Evaluate Flextronics FXS-260BB-MAA1B (252.8 W STC, 37.98 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Flextronics FXS-260BB-MAA1B reaches 44.1 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 32 panels for an 8 kW build require 560 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 32 panels (560 sq ft).
- 2026 tax credit baseline: cash residential installs of Flextronics FXS-260BB-MAA1B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Flextronics FXS-260BB-MAA1B 8 kW Residential Fit
Needs 32 modules (560 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Changzhou Nesl Solartech DJ-255D/C-ST15.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 229.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Flextronics FXS-260BB-MAA1B by Flextronics grounded in CEC test data and NEC 690.7/690.8 limits. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
What fuse or breaker size does NEC 690.8 require for Flextronics FXS-260BB-MAA1B?
Multiplying Flextronics FXS-260BB-MAA1B's 8.55 A short-circuit current by 1.56 equals 13.34 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for Flextronics FXS-260BB-MAA1B before finalizing component orders.
Can Flextronics FXS-260BB-MAA1B pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 42.74 V cold Voc at 14 F and handles 8.55 A Isc; string inverters cap Flextronics FXS-260BB-MAA1B at 14 panels on 600 V.
Is Flextronics FXS-260BB-MAA1B eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Flextronics FXS-260BB-MAA1B rely on utility bill offset (~$2,025/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)