Skip to main content
WireAndSun
Calculators
CEC PV Module

Flextronics FXS-350BC-SBD1W — CEC Solar Module Specifications

Manufacturer: Flextronics Registry: CEC Verified Engineering Specification

Flextronics FXS-350BC-SBD1W is a 340.2 W STC (311.4 W PTC) Multi-c-Si solar module ranking #13,573 of 21,677 CEC listings (below all-CEC median; higher than 37.4% of peers). It delivers 17.36% efficiency, 47.79 V Voc at 25 C, and 53.19 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
340.2 W
PTC Wattage
311.4 W
Voc @ 25C
47.79 V
Efficiency
17.36%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Flextronics FXS-350BC-SBD1W Compare Against Peer CEC Listings?

Solar engineering breakdown for Flextronics FXS-350BC-SBD1W: PTC thermal retention, roof footprint, and cold Voc string bounds. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Across 1,407 Multi-c-Si listings from Flextronics and peers, Flextronics FXS-350BC-SBD1W stands 61.4 W above the 278.8 W Multi-c-Si median and strong 91.5% PTC-to-STC heat retention (#15,584 of 21,677). Sizing 6 kW (18 panels) to 10 kW (30 panels) yields $1,532-$2,555/yr in baseline US bill offset. Mid-range 47.79 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

Where Does Flextronics FXS-350BC-SBD1W Fall Across Listed CEC Models?

Distribution marker showing Flextronics FXS-350BC-SBD1W (340.2 W) relative to the 385.0 W all-CEC solar panel median. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Flextronics FXS-350BC-SBD1W (340.2 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFlextronics FXS-35: 340.2 W

What Dataset Percentiles Define Flextronics FXS-350BC-SBD1W?

Dataset percentiles tracking Flextronics FXS-350BC-SBD1W power output, thermal retention ratio, and aperture efficiency against 21,677 models. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Flextronics FXS-350BC-SBD1W Engineering BenchmarksPercentile comparison of Flextronics FXS-350BC-SBD1W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage340.2 WPTC/STC Retention91.5%Module Efficiency17.36%

What Do the Dataset Ranks Show for Flextronics FXS-350BC-SBD1W?

Benchmark highlights for Flextronics FXS-350BC-SBD1W covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Rank #13,573 / 21,677

340.2 W STC · Higher Than 37.4%

340.2 W STC (-44.8 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #15,987

17.36% Aperture Efficiency

Power density 173.6 W/m2 (2.55 percentage points below 19.91% CEC median). PTC/STC ratio: 91.5% (rank #15,584).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.19 V at -10 C (585.1 V string) and 54.74 V at -20 C (10 max).

8 kW Reference Array

24 Panels = 8,165 W STC

Occupies 47.0 m2 (506 sq ft) producing 7,474 W PTC; NEC 690.8 OCPD floor is 14.49 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.79 * (1 + (-0.323/100) * (-10 - 25)) = 53.19 V | OCPD = 1.56 * 9.29 = 14.49 A

Inputs from CEC Modules.csv for Flextronics FXS-350BC-SBD1W: Voc=47.79 V, beta_Voc=-0.323%/C, Isc=9.29 A, STC=340.2 W, Area=1.96 m2.

Result: 11 panels max on 600 V (585.1 V); 24 panels for 8 kW (506 sq ft).

What Are the Published CEC Specifications for Flextronics FXS-350BC-SBD1W?

Official CEC datasheet figures for Flextronics FXS-350BC-SBD1W (Multi-c-Si) used in utility interconnection and permit reviews. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Official California Energy Commission (NREL SAM) test parameters for Flextronics FXS-350BC-SBD1W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 340.2 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 311.4 W (91.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 47.79 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.29 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.54 V / 8.83 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.323 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.36% (1.96 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Flextronics FXS-350BC-SBD1W Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Flextronics FXS-350BC-SBD1W modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 18 6.12 kW 380 sq ft $1,532 $2,590
8 kW Class 24 8.16 kW 506 sq ft $2,042 $3,454
10 kW Class 30 10.21 kW 633 sq ft $2,555 $4,321

How Many Flextronics FXS-350BC-SBD1W Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Flextronics FXS-350BC-SBD1W (53.19 V at 14 F). Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Computed from Voc=47.79V and beta_Voc=-0.323%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.74 V 10 panels 547.4 V 18 panels
-10 C (14 F) 53.19 V 11 panels 585.1 V 18 panels
0 C (32 F) 51.65 V 11 panels 568.1 V 19 panels
25 C (77 F STC) 47.79 V 12 panels 573.5 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Flextronics FXS-350BC-SBD1W?

Competing CEC solar panels closest to Flextronics FXS-350BC-SBD1W in nameplate wattage and Voc, starting with DEHUI SOLAR POWER INC DH-72M-340W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
DEHUI SOLAR POWER INC DH-72M-340W
DEHUI SOLAR POWER INC
340.0 W -0.2 W 47.3 V 17.68% 91.3%
Advance Power API-M340
Advance Power
340.0 W -0.2 W 47.18 V 17.53% 91.7%
Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM340-72
Anhui Rinengzhongtian Semiconductor Development Co Ltd
340.0 W -0.2 W 46.97 V 17.52% 91.0%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-340W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
340.0 W -0.2 W 46.91 V 17.68% 91.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Flextronics FXS-350BC-SBD1W?

Evaluate Flextronics FXS-350BC-SBD1W (340.2 W STC, 47.79 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Flextronics FXS-350BC-SBD1W reaches 54.74 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 24 panels for an 8 kW build require 506 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (506 sq ft).
  • 2026 tax credit baseline: cash residential installs of Flextronics FXS-350BC-SBD1W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Flextronics FXS-350BC-SBD1W 8 kW Residential Fit

Needs 24 modules (506 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare DEHUI SOLAR POWER INC DH-72M-340W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 311.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Flextronics FXS-350BC-SBD1W by Flextronics grounded in CEC test data and NEC 690.7/690.8 limits. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

What fuse or breaker size does NEC 690.8 require for Flextronics FXS-350BC-SBD1W?

Multiplying Flextronics FXS-350BC-SBD1W's 9.29 A short-circuit current by 1.56 equals 14.49 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for Flextronics FXS-350BC-SBD1W before finalizing component orders.

Can Flextronics FXS-350BC-SBD1W pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 53.19 V cold Voc at 14 F and handles 9.29 A Isc; string inverters cap Flextronics FXS-350BC-SBD1W at 11 panels on 600 V.

Is Flextronics FXS-350BC-SBD1W eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Flextronics FXS-350BC-SBD1W rely on utility bill offset (~$2,042/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls