Skip to main content
WireAndSun
Calculators
CEC PV Module

Heliene 72M-395 G1 — CEC Solar Module Specifications

Manufacturer: Heliene Registry: CEC Verified Engineering Specification

Heliene 72M-395 G1 is a 395.0 W STC (365.4 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.57% efficiency, 49.26 V Voc at 25 C, and 53.74 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
395.0 W
PTC Wattage
365.4 W
Voc @ 25C
49.26 V
Efficiency
20.57%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Heliene 72M-395 G1 Compare Against Peer CEC Listings?

Engineering position of Heliene 72M-395 G1 (395.0 W STC) vs. ELITE Solar ET-M672BH395WW across 5,889 CEC Mono-c-Si solar modules.

Ranking #9,869 across 21,677 CEC solar panels (top 47.6%; higher than 52.4% of peers), Heliene 72M-395 G1 operates as a modern high-density residential and light-commercial module sitting 15.0 W below the 410.0 W Mono-c-Si median. Higher 49.26 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C). With strong 92.5% PTC-to-STC heat retention (#12,531 of 21,677), 21 panels occupy 434 sq ft and offset roughly $2,075/yr at average US rates (or $3,509/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Heliene 72M-395 G1 Fall Across Listed CEC Models?

Plots Heliene 72M-395 G1 at 395.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Heliene 72M-395 G1 (395.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHeliene 72M-395 G1: 395.0 W

What Dataset Percentiles Define Heliene 72M-395 G1?

Benchmarks Heliene 72M-395 G1 on STC wattage, thermal PTC/STC retention, and 20.57 aperture conversion efficiency against CEC peers.

Heliene 72M-395 G1 Engineering BenchmarksPercentile comparison of Heliene 72M-395 G1 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage395.0 WPTC/STC Retention92.5%Module Efficiency20.57%

What Do the Dataset Ranks Show for Heliene 72M-395 G1?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Heliene 72M-395 G1 by Heliene.

Rank #9,869 / 21,677

Top 47.6% STC Output

395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,219

20.57% Aperture Efficiency

Power density 205.7 W/m2 (0.66 percentage points above 19.91% CEC median). PTC/STC ratio: 92.5% (rank #12,531).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.74 V at -10 C (591.1 V string) and 55.02 V at -20 C (10 max).

8 kW Reference Array

21 Panels = 8,295 W STC

Occupies 40.3 m2 (434 sq ft) producing 7,673 W PTC; NEC 690.8 OCPD floor is 16.05 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.26 * (1 + (-0.26/100) * (-10 - 25)) = 53.74 V | OCPD = 1.56 * 10.29 = 16.05 A

Inputs from CEC Modules.csv for Heliene 72M-395 G1: Voc=49.26 V, beta_Voc=-0.26%/C, Isc=10.29 A, STC=395.0 W, Area=1.92 m2.

Result: 11 panels max on 600 V (591.1 V); 21 panels for 8 kW (434 sq ft).

What Are the Published CEC Specifications for Heliene 72M-395 G1?

Laboratory test ratings recorded for Heliene 72M-395 G1 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Heliene 72M-395 G1.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 395.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 365.4 W (92.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.26 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.29 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.4 V / 9.78 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.26 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.57% (1.92 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Heliene 72M-395 G1 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (434 sq ft at 8 kW), and estimated Year-1 electric bill offset for Heliene 72M-395 G1.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.32 kW 331 sq ft $1,582 $2,675
8 kW Class 21 8.29 kW 434 sq ft $2,075 $3,509
10 kW Class 26 10.27 kW 537 sq ft $2,570 $4,347

How Many Heliene 72M-395 G1 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Heliene 72M-395 G1 (beta_Voc -0.26%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=49.26V and beta_Voc=-0.26%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.02 V 10 panels 550.2 V 18 panels
-10 C (14 F) 53.74 V 11 panels 591.1 V 18 panels
0 C (32 F) 52.46 V 11 panels 577.1 V 19 panels
25 C (77 F STC) 49.26 V 12 panels 591.1 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Heliene 72M-395 G1?

Closest cross-brand CEC competitors to Heliene 72M-395 G1 matched near 395.0 W STC and 49.26 V Voc, led by ELITE Solar ET-M672BH395WW.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
ELITE Solar ET-M672BH395WW
ELITE Solar
395.0 W Tie (0 W) 49.5 V 19.85% 93.3%
ELITE Solar ET-M672BH395GL
ELITE Solar
395.0 W Tie (0 W) 49.6 V 19.36% 93.2%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
395.0 W Tie (0 W) 48.7 V 20.26% 92.9%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-395W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
395.0 W Tie (0 W) 48.7 V 20.68% 92.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Heliene 72M-395 G1?

Evaluate Heliene 72M-395 G1 (395.0 W STC, 49.26 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Heliene 72M-395 G1 reaches 55.02 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 434 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (434 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Heliene 72M-395 G1 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Heliene 72M-395 G1 8 kW Residential Fit

Needs 21 modules (434 sq ft) with a 20 A string OCPD, offsetting ~$2,075/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare ELITE Solar ET-M672BH395WW.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 365.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Heliene 72M-395 G1 by Heliene grounded in CEC test data and NEC 690.7/690.8 limits.

How many Heliene 72M-395 G1 panels fit on a 600 V winter solar string?

At -10 C (14 F), Heliene 72M-395 G1 cold Voc rises from 49.26 V to 53.74 V (beta_Voc -0.26%/C), capping a 600 V string at 11 panels (591.1 V).

How much roof area does an 8 kW array of Heliene 72M-395 G1 need?

An 8 kW DC system uses 21 Heliene 72M-395 G1 modules (8,295 W STC / 7,673 W PTC), covering roughly 434 sq ft and saving ~$2,075/yr at 18.54 c/kWh.

How does Heliene 72M-395 G1 compare against ELITE Solar ET-M672BH395WW?

Heliene 72M-395 G1 outputs 395.0 W STC (49.26 V Voc, rank #9,869 of 21,677), while ELITE Solar ET-M672BH395WW delivers 395.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.