Skip to main content
WireAndSun
Calculators
CEC PV Module

Heliene 20M-100GH — CEC Solar Module Specifications

Manufacturer: Heliene Registry: CEC Verified Engineering Specification

Heliene 20M-100GH is a 100.0 W STC (85.2 W PTC) Mono-c-Si solar module ranking #21,563 of 21,677 CEC listings (below all-CEC median; higher than 0.5% of peers). It delivers 6.17% efficiency, 13.3 V Voc at 25 C, and 14.87 V cold Voc at -10 C (40 panels max per 600 V string).

STC Wattage
100.0 W
PTC Wattage
85.2 W
Voc @ 25C
13.3 V
Efficiency
6.17%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Heliene 20M-100GH Compare Against Peer CEC Listings?

Solar engineering breakdown for Heliene 20M-100GH: PTC thermal retention, roof footprint, and cold Voc string bounds. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Measured at 100.0 W STC and 85.2 W PTC, Heliene 20M-100GH sits -285.0 W vs all-CEC median (below all-CEC median; higher than 0.5% of peers) among 21,677 listed modules. Power density reaches 61.7 W/m2 (13.74 percentage points below 19.91% CEC median). Lower 13.3 V string voltage fits 40 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 67 panels in series. Alternative peer Merlin Solar Technologies Inc FXS 100-B rates 100.0 W.

Where Does Heliene 20M-100GH Fall Across Listed CEC Models?

Distribution marker showing Heliene 20M-100GH (100.0 W) relative to the 385.0 W all-CEC solar panel median. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Heliene 20M-100GH (100.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHeliene 20M-100GH: 100.0 W

What Dataset Percentiles Define Heliene 20M-100GH?

Dataset percentiles tracking Heliene 20M-100GH power output, thermal retention ratio, and aperture efficiency against 21,677 models. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Heliene 20M-100GH Engineering BenchmarksPercentile comparison of Heliene 20M-100GH wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage100.0 WPTC/STC Retention85.2%Module Efficiency6.17%

What Do the Dataset Ranks Show for Heliene 20M-100GH?

Benchmark highlights for Heliene 20M-100GH covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Rank #21,563 / 21,677

100.0 W STC · Higher Than 0.5%

100.0 W STC (-285.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #21,676

6.17% Aperture Efficiency

Power density 61.7 W/m2 (13.74 percentage points below 19.91% CEC median). PTC/STC ratio: 85.2% (rank #21,665).

NEC 690.7 Limit

40 Panels Max @ -10 C (600 V)

Cold Voc reaches 14.87 V at -10 C (594.8 V string) and 15.32 V at -20 C (39 max).

8 kW Reference Array

80 Panels = 8,000 W STC

Occupies 129.6 m2 (1,395 sq ft) producing 6,816 W PTC; NEC 690.8 OCPD floor is 15.18 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 13.3 * (1 + (-0.338/100) * (-10 - 25)) = 14.87 V | OCPD = 1.56 * 9.73 = 15.18 A

Inputs from CEC Modules.csv for Heliene 20M-100GH: Voc=13.3 V, beta_Voc=-0.338%/C, Isc=9.73 A, STC=100.0 W, Area=1.62 m2.

Result: 40 panels max on 600 V (594.8 V); 80 panels for 8 kW (1,395 sq ft).

What Are the Published CEC Specifications for Heliene 20M-100GH?

Official CEC datasheet figures for Heliene 20M-100GH (Mono-c-Si) used in utility interconnection and permit reviews. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Official California Energy Commission (NREL SAM) test parameters for Heliene 20M-100GH.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 100.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 85.2 W (85.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 13.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.73 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 11.16 V / 9.2 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.338 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 6.17% (1.62 m2) Array roof footprint density
Cell Count & Technology 20 cells (Mono-c-Si) Monofacial backsheet

How Many Heliene 20M-100GH Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Heliene 20M-100GH modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 60 6.0 kW 1,046 sq ft $1,502 $2,539
8 kW Class 80 8.0 kW 1,395 sq ft $2,002 $3,386
10 kW Class 100 10.0 kW 1,744 sq ft $2,503 $4,232

How Many Heliene 20M-100GH Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Heliene 20M-100GH (14.87 V at 14 F). Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Computed from Voc=13.3V and beta_Voc=-0.338%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 15.32 V 39 panels 597.5 V 65 panels
-10 C (14 F) 14.87 V 40 panels 594.8 V 67 panels
0 C (32 F) 14.42 V 41 panels 591.2 V 69 panels
25 C (77 F STC) 13.3 V 45 panels 598.5 V 75 panels

Which Cross-Brand Solar Modules Compare Closest to Heliene 20M-100GH?

Competing CEC solar panels closest to Heliene 20M-100GH in nameplate wattage and Voc, starting with Merlin Solar Technologies Inc FXS 100-B.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Merlin Solar Technologies Inc FXS 100-B
Merlin Solar Technologies Inc
100.0 W Tie (0 W) 15.33 V 13.33% 88.3%
Merlin Solar Technologies Inc FXS 95-B
Merlin Solar Technologies Inc
95.0 W -5.0 W 15.08 V 12.67% 88.2%
Merlin Solar Technologies Inc FXS 105-W
Merlin Solar Technologies Inc
105.0 W +5.0 W 15.5 V 14.0% 91.6%
Luma Resources LLC LRSS28-100A
Luma Resources LLC
100.0 W Tie (0 W) 9.73 V 17.24% 98.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Heliene 20M-100GH?

Evaluate Heliene 20M-100GH (100.0 W STC, 13.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Heliene 20M-100GH reaches 15.32 V per panel—exceeding 39 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 80 panels for an 8 kW build require 1,395 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 80 panels (1,395 sq ft).
  • 2026 tax credit baseline: cash residential installs of Heliene 20M-100GH carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Heliene 20M-100GH 8 kW Residential Fit

Needs 80 modules (1,395 sq ft) with a 20 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 40 panels (-10 C) or 39 panels (-20 C), or compare Merlin Solar Technologies Inc FXS 100-B.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 85.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Heliene 20M-100GH by Heliene grounded in CEC test data and NEC 690.7/690.8 limits. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

How many Heliene 20M-100GH panels fit on a 600 V winter solar string?

At -10 C (14 F), Heliene 20M-100GH cold Voc rises from 13.3 V to 14.87 V (beta_Voc -0.338%/C), capping a 600 V string at 40 panels (594.8 V).

How much roof area does an 8 kW array of Heliene 20M-100GH need?

An 8 kW DC system uses 80 Heliene 20M-100GH modules (8,000 W STC / 6,816 W PTC), covering roughly 1,395 sq ft and saving ~$2,002/yr at 18.54 c/kWh.

How does Heliene 20M-100GH compare against Merlin Solar Technologies Inc FXS 100-B?

Heliene 20M-100GH outputs 100.0 W STC (13.3 V Voc, rank #21,563 of 21,677), while Merlin Solar Technologies Inc FXS 100-B delivers 100.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.