Heliene 20M-100GH is a 100.0 W STC (85.2 W PTC) Mono-c-Si solar module ranking #21,563 of 21,677 CEC listings (below all-CEC median; higher than 0.5% of peers). It delivers 6.17% efficiency, 13.3 V Voc at 25 C, and 14.87 V cold Voc at -10 C (40 panels max per 600 V string).
- STC Wattage
- 100.0 W
- PTC Wattage
- 85.2 W
- Voc @ 25C
- 13.3 V
- Efficiency
- 6.17%
How Does Heliene 20M-100GH Compare Against Peer CEC Listings?
Solar engineering breakdown for Heliene 20M-100GH: PTC thermal retention, roof footprint, and cold Voc string bounds. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
Measured at 100.0 W STC and 85.2 W PTC, Heliene 20M-100GH sits -285.0 W vs all-CEC median (below all-CEC median; higher than 0.5% of peers) among 21,677 listed modules. Power density reaches 61.7 W/m2 (13.74 percentage points below 19.91% CEC median). Lower 13.3 V string voltage fits 40 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 67 panels in series. Alternative peer Merlin Solar Technologies Inc FXS 100-B rates 100.0 W.
Where Does Heliene 20M-100GH Fall Across Listed CEC Models?
Distribution marker showing Heliene 20M-100GH (100.0 W) relative to the 385.0 W all-CEC solar panel median. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
What Dataset Percentiles Define Heliene 20M-100GH?
Dataset percentiles tracking Heliene 20M-100GH power output, thermal retention ratio, and aperture efficiency against 21,677 models. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What Do the Dataset Ranks Show for Heliene 20M-100GH?
Benchmark highlights for Heliene 20M-100GH covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
100.0 W STC · Higher Than 0.5%
100.0 W STC (-285.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
6.17% Aperture Efficiency
Power density 61.7 W/m2 (13.74 percentage points below 19.91% CEC median). PTC/STC ratio: 85.2% (rank #21,665).
40 Panels Max @ -10 C (600 V)
Cold Voc reaches 14.87 V at -10 C (594.8 V string) and 15.32 V at -20 C (39 max).
80 Panels = 8,000 W STC
Occupies 129.6 m2 (1,395 sq ft) producing 6,816 W PTC; NEC 690.8 OCPD floor is 15.18 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 13.3 * (1 + (-0.338/100) * (-10 - 25)) = 14.87 V | OCPD = 1.56 * 9.73 = 15.18 A
Inputs from CEC Modules.csv for Heliene 20M-100GH: Voc=13.3 V, beta_Voc=-0.338%/C, Isc=9.73 A, STC=100.0 W, Area=1.62 m2.
Result: 40 panels max on 600 V (594.8 V); 80 panels for 8 kW (1,395 sq ft).
What Are the Published CEC Specifications for Heliene 20M-100GH?
Official CEC datasheet figures for Heliene 20M-100GH (Mono-c-Si) used in utility interconnection and permit reviews. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 100.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 85.2 W (85.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 13.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.73 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 11.16 V / 9.2 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.338 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 6.17% (1.62 m2) | Array roof footprint density |
| Cell Count & Technology | 20 cells (Mono-c-Si) | Monofacial backsheet |
How Many Heliene 20M-100GH Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Heliene 20M-100GH modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 60 | 6.0 kW | 1,046 sq ft | $1,502 | $2,539 |
| 8 kW Class | 80 | 8.0 kW | 1,395 sq ft | $2,002 | $3,386 |
| 10 kW Class | 100 | 10.0 kW | 1,744 sq ft | $2,503 | $4,232 |
How Many Heliene 20M-100GH Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Heliene 20M-100GH (14.87 V at 14 F). Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 15.32 V | 39 panels | 597.5 V | 65 panels |
| -10 C (14 F) | 14.87 V | 40 panels | 594.8 V | 67 panels |
| 0 C (32 F) | 14.42 V | 41 panels | 591.2 V | 69 panels |
| 25 C (77 F STC) | 13.3 V | 45 panels | 598.5 V | 75 panels |
Which Cross-Brand Solar Modules Compare Closest to Heliene 20M-100GH?
Competing CEC solar panels closest to Heliene 20M-100GH in nameplate wattage and Voc, starting with Merlin Solar Technologies Inc FXS 100-B.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Merlin Solar Technologies Inc FXS 100-B Merlin Solar Technologies Inc |
100.0 W | Tie (0 W) | 15.33 V | 13.33% | 88.3% |
| Merlin Solar Technologies Inc FXS 95-B Merlin Solar Technologies Inc |
95.0 W | -5.0 W | 15.08 V | 12.67% | 88.2% |
| Merlin Solar Technologies Inc FXS 105-W Merlin Solar Technologies Inc |
105.0 W | +5.0 W | 15.5 V | 14.0% | 91.6% |
| Luma Resources LLC LRSS28-100A Luma Resources LLC |
100.0 W | Tie (0 W) | 9.73 V | 17.24% | 98.9% |
What Are the Design Limits and Best-Fit Uses for Heliene 20M-100GH?
Evaluate Heliene 20M-100GH (100.0 W STC, 13.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Heliene 20M-100GH reaches 15.32 V per panel—exceeding 39 panels in series voids 600 V inverter warranties.
- Footprint constraint: 80 panels for an 8 kW build require 1,395 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 80 panels (1,395 sq ft).
- 2026 tax credit baseline: cash residential installs of Heliene 20M-100GH carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Heliene 20M-100GH 8 kW Residential Fit
Needs 80 modules (1,395 sq ft) with a 20 A string OCPD, offsetting ~$2,002/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 40 panels (-10 C) or 39 panels (-20 C), or compare Merlin Solar Technologies Inc FXS 100-B.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 85.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Heliene 20M-100GH by Heliene grounded in CEC test data and NEC 690.7/690.8 limits. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
How many Heliene 20M-100GH panels fit on a 600 V winter solar string?
At -10 C (14 F), Heliene 20M-100GH cold Voc rises from 13.3 V to 14.87 V (beta_Voc -0.338%/C), capping a 600 V string at 40 panels (594.8 V).
How much roof area does an 8 kW array of Heliene 20M-100GH need?
An 8 kW DC system uses 80 Heliene 20M-100GH modules (8,000 W STC / 6,816 W PTC), covering roughly 1,395 sq ft and saving ~$2,002/yr at 18.54 c/kWh.
How does Heliene 20M-100GH compare against Merlin Solar Technologies Inc FXS 100-B?
Heliene 20M-100GH outputs 100.0 W STC (13.3 V Voc, rank #21,563 of 21,677), while Merlin Solar Technologies Inc FXS 100-B delivers 100.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)