Skip to main content
WireAndSun
Calculators
CEC PV Module

Luma Resources LLC LRSS28-100A — CEC Solar Module Specifications

Manufacturer: Luma Resources LLC Registry: CEC Verified Engineering Specification

Luma Resources LLC LRSS28-100A is a 100.0 W STC (98.9 W PTC) Mono-c-Si solar module ranking #21,563 of 21,677 CEC listings (below all-CEC median; higher than 0.5% of peers). It delivers 17.24% efficiency, 9.73 V Voc at 25 C, and 10.61 V cold Voc at -10 C (56 panels max per 600 V string).

STC Wattage
100.0 W
PTC Wattage
98.9 W
Voc @ 25C
9.73 V
Efficiency
17.24%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Luma Resources LLC LRSS28-100A Compare Against Peer CEC Listings?

How Luma Resources LLC Luma Resources LLC LRSS28-100A handles rooftop heat (98.9 W PTC), 8 kW sizing, and cold winter string voltage.

Luma Resources LLC builds the Luma Resources LLC LRSS28-100A (Mono-c-Si) as a compact residential or specialty off-grid module delivering 172.4 W/m2 (2.67 percentage points below 19.91% CEC median). Compared against Heliene 20M-100GH (100.0 W), this model holds strong 98.9% PTC-to-STC heat retention (#11 of 21,677). Lower 9.73 V string voltage fits 56 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 20.83 A overcurrent floor served by a 25 A breaker.

Where Does Luma Resources LLC LRSS28-100A Fall Across Listed CEC Models?

Where Luma Resources LLC LRSS28-100A (100.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Luma Resources LLC LRSS28-100A (100.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCLuma Resources LLC: 100.0 W

What Dataset Percentiles Define Luma Resources LLC LRSS28-100A?

Percentile placement of Luma Resources LLC LRSS28-100A across power density (172.4 W/m2), thermal retention, and nameplate STC wattage.

Luma Resources LLC LRSS28-100A Engineering BenchmarksPercentile comparison of Luma Resources LLC LRSS28-100A wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage100.0 WPTC/STC Retention98.9%Module Efficiency17.24%

What Do the Dataset Ranks Show for Luma Resources LLC LRSS28-100A?

Four critical engineering numbers homeowners and solar installers check first when reviewing Luma Resources LLC LRSS28-100A specifications. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Rank #21,563 / 21,677

100.0 W STC · Higher Than 0.5%

100.0 W STC (-285.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #16,169

17.24% Aperture Efficiency

Power density 172.4 W/m2 (2.67 percentage points below 19.91% CEC median). PTC/STC ratio: 98.9% (rank #11).

NEC 690.7 Limit

56 Panels Max @ -10 C (600 V)

Cold Voc reaches 10.61 V at -10 C (594.2 V string) and 10.86 V at -20 C (55 max).

8 kW Reference Array

80 Panels = 8,000 W STC

Occupies 46.4 m2 (499 sq ft) producing 7,912 W PTC; NEC 690.8 OCPD floor is 20.83 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 9.73 * (1 + (-0.259/100) * (-10 - 25)) = 10.61 V | OCPD = 1.56 * 13.35 = 20.83 A

Inputs from CEC Modules.csv for Luma Resources LLC LRSS28-100A: Voc=9.73 V, beta_Voc=-0.259%/C, Isc=13.35 A, STC=100.0 W, Area=0.58 m2.

Result: 56 panels max on 600 V (594.2 V); 80 panels for 8 kW (499 sq ft).

What Are the Published CEC Specifications for Luma Resources LLC LRSS28-100A?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Luma Resources LLC LRSS28-100A.

Official California Energy Commission (NREL SAM) test parameters for Luma Resources LLC LRSS28-100A.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 100.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 98.9 W (98.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 9.73 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.35 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 7.8 V / 12.82 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.259 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.24% (0.58 m2) Array roof footprint density
Cell Count & Technology 28 cells (Mono-c-Si) Monofacial backsheet

How Many Luma Resources LLC LRSS28-100A Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Luma Resources LLC LRSS28-100A (100.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 60 6.0 kW 375 sq ft $1,502 $2,539
8 kW Class 80 8.0 kW 499 sq ft $2,002 $3,386
10 kW Class 100 10.0 kW 624 sq ft $2,503 $4,232

How Many Luma Resources LLC LRSS28-100A Modules Fit in a Cold-Weather String?

Maximum series module counts for Luma Resources LLC LRSS28-100A from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=9.73V and beta_Voc=-0.259%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 10.86 V 55 panels 597.3 V 92 panels
-10 C (14 F) 10.61 V 56 panels 594.2 V 94 panels
0 C (32 F) 10.36 V 57 panels 590.5 V 96 panels
25 C (77 F STC) 9.73 V 61 panels 593.5 V 102 panels

Which Cross-Brand Solar Modules Compare Closest to Luma Resources LLC LRSS28-100A?

Alternative CEC solar modules from competing brands near Luma Resources LLC LRSS28-100A (100.0 W), including Heliene 20M-100GH. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Heliene 20M-100GH
Heliene
100.0 W Tie (0 W) 13.3 V 6.17% 85.2%
Arka Energy Inc AEP-821-00015-A
Arka Energy Inc
88.0 W -12.0 W 8.84 V 14.92% 91.5%
Merlin Solar Technologies Inc FXS 100-B
Merlin Solar Technologies Inc
100.0 W Tie (0 W) 15.33 V 13.33% 88.3%
CertainTeed Apollo II - 75x
CertainTeed
75.0 W -25.0 W 9.92 V 14.15% 85.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Luma Resources LLC LRSS28-100A?

Evaluate Luma Resources LLC LRSS28-100A (100.0 W STC, 9.73 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Luma Resources LLC LRSS28-100A reaches 10.86 V per panel—exceeding 55 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 80 panels for an 8 kW build require 499 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 80 panels (499 sq ft).
  • 2026 tax credit baseline: cash residential installs of Luma Resources LLC LRSS28-100A carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Luma Resources LLC LRSS28-100A 8 kW Residential Fit

Needs 80 modules (499 sq ft) with a 25 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 56 panels (-10 C) or 55 panels (-20 C), or compare Heliene 20M-100GH.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 98.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Luma Resources LLC LRSS28-100A by Luma Resources LLC grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Luma Resources LLC LRSS28-100A?

Multiplying Luma Resources LLC LRSS28-100A's 13.35 A short-circuit current by 1.56 equals 20.83 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Luma Resources LLC LRSS28-100A pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 10.61 V cold Voc at 14 F and handles 13.35 A Isc; string inverters cap Luma Resources LLC LRSS28-100A at 56 panels on 600 V.

Is Luma Resources LLC LRSS28-100A eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Luma Resources LLC LRSS28-100A rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.