Merlin Solar Technologies Inc FXS 100-B is a 100.0 W STC (88.3 W PTC) Mono-c-Si solar module ranking #21,563 of 21,677 CEC listings (below all-CEC median; higher than 0.5% of peers). It delivers 13.33% efficiency, 15.33 V Voc at 25 C, and 16.99 V cold Voc at -10 C (35 panels max per 600 V string).
- STC Wattage
- 100.0 W
- PTC Wattage
- 88.3 W
- Voc @ 25C
- 15.33 V
- Efficiency
- 13.33%
How Does Merlin Solar Technologies Inc FXS 100-B Compare Against Peer CEC Listings?
Engineering position of Merlin Solar Technologies Inc FXS 100-B (100.0 W STC) vs. Heliene 20M-100GH across 5,889 CEC Mono-c-Si solar modules.
Ranking #21,563 across 21,677 CEC solar panels (below all-CEC median; higher than 0.5% of peers), Merlin Solar Technologies Inc FXS 100-B operates as a compact residential or specialty off-grid module sitting 310.0 W below the 410.0 W Mono-c-Si median. Lower 15.33 V string voltage fits 35 panels in series at 14 F and pairs easily with microinverters. With typical 88.3% PTC-to-STC thermal output (88.3 W real-world rating), 80 panels occupy 646 sq ft and offset roughly $2,002/yr at average US rates (or $3,386/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Merlin Solar Technologies Inc FXS 100-B Fall Across Listed CEC Models?
Plots Merlin Solar Technologies Inc FXS 100-B at 100.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Merlin Solar Technologies Inc FXS 100-B?
Benchmarks Merlin Solar Technologies Inc FXS 100-B on STC wattage, thermal PTC/STC retention, and 13.33 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Merlin Solar Technologies Inc FXS 100-B?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Merlin Solar Technologies Inc FXS 100-B by Merlin Solar Technologies Inc.
100.0 W STC · Higher Than 0.5%
100.0 W STC (-285.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
13.33% Aperture Efficiency
Power density 133.3 W/m2 (6.58 percentage points below 19.91% CEC median). PTC/STC ratio: 88.3% (rank #21,245).
35 Panels Max @ -10 C (600 V)
Cold Voc reaches 16.99 V at -10 C (594.6 V string) and 17.47 V at -20 C (34 max).
80 Panels = 8,000 W STC
Occupies 60.0 m2 (646 sq ft) producing 7,064 W PTC; NEC 690.8 OCPD floor is 13.34 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 15.33 * (1 + (-0.31/100) * (-10 - 25)) = 16.99 V | OCPD = 1.56 * 8.55 = 13.34 A
Inputs from CEC Modules.csv for Merlin Solar Technologies Inc FXS 100-B: Voc=15.33 V, beta_Voc=-0.31%/C, Isc=8.55 A, STC=100.0 W, Area=0.75 m2.
Result: 35 panels max on 600 V (594.6 V); 80 panels for 8 kW (646 sq ft).
What Are the Published CEC Specifications for Merlin Solar Technologies Inc FXS 100-B?
Laboratory test ratings recorded for Merlin Solar Technologies Inc FXS 100-B (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 100.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 88.3 W (88.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 15.33 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.55 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 12.3 V / 8.18 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.31 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.33% (0.75 m2) | Array roof footprint density |
| Cell Count & Technology | 24 cells (Mono-c-Si) | Monofacial backsheet |
How Many Merlin Solar Technologies Inc FXS 100-B Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (646 sq ft at 8 kW), and estimated Year-1 electric bill offset for Merlin Solar Technologies Inc FXS 100-B.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 60 | 6.0 kW | 484 sq ft | $1,502 | $2,539 |
| 8 kW Class | 80 | 8.0 kW | 646 sq ft | $2,002 | $3,386 |
| 10 kW Class | 100 | 10.0 kW | 807 sq ft | $2,503 | $4,232 |
How Many Merlin Solar Technologies Inc FXS 100-B Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Merlin Solar Technologies Inc FXS 100-B (beta_Voc -0.31%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 17.47 V | 34 panels | 594.0 V | 57 panels |
| -10 C (14 F) | 16.99 V | 35 panels | 594.6 V | 58 panels |
| 0 C (32 F) | 16.52 V | 36 panels | 594.7 V | 60 panels |
| 25 C (77 F STC) | 15.33 V | 39 panels | 597.9 V | 65 panels |
Which Cross-Brand Solar Modules Compare Closest to Merlin Solar Technologies Inc FXS 100-B?
Closest cross-brand CEC competitors to Merlin Solar Technologies Inc FXS 100-B matched near 100.0 W STC and 15.33 V Voc, led by Heliene 20M-100GH.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Heliene 20M-100GH Heliene |
100.0 W | Tie (0 W) | 13.3 V | 6.17% | 85.2% |
| SunStyle M110 870 SunStyle |
110.0 W | +10.0 W | 16.1 V | 14.47% | 89.3% |
| SunTegra STS-114M-B4U SunTegra |
114.0 W | +14.0 W | 15.52 V | 17.27% | 86.8% |
| SUNSTYLE AG / LTD SUNSTYLE M80 SUNSTYLE AG / LTD |
80.0 W | -20.0 W | 15.7 V | 11.19% | 91.0% |
What Are the Design Limits and Best-Fit Uses for Merlin Solar Technologies Inc FXS 100-B?
Evaluate Merlin Solar Technologies Inc FXS 100-B (100.0 W STC, 15.33 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Merlin Solar Technologies Inc FXS 100-B reaches 17.47 V per panel—exceeding 34 panels in series voids 600 V inverter warranties.
- Footprint constraint: 80 panels for an 8 kW build require 646 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 80 panels (646 sq ft).
- 2026 tax credit baseline: cash residential installs of Merlin Solar Technologies Inc FXS 100-B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Merlin Solar Technologies Inc FXS 100-B 8 kW Residential Fit
Needs 80 modules (646 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 35 panels (-10 C) or 34 panels (-20 C), or compare Heliene 20M-100GH.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 88.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Merlin Solar Technologies Inc FXS 100-B by Merlin Solar Technologies Inc grounded in CEC test data and NEC 690.7/690.8 limits.
How many Merlin Solar Technologies Inc FXS 100-B panels fit on a 600 V winter solar string?
At -10 C (14 F), Merlin Solar Technologies Inc FXS 100-B cold Voc rises from 15.33 V to 16.99 V (beta_Voc -0.31%/C), capping a 600 V string at 35 panels (594.6 V).
How much roof area does an 8 kW array of Merlin Solar Technologies Inc FXS 100-B need?
An 8 kW DC system uses 80 Merlin Solar Technologies Inc FXS 100-B modules (8,000 W STC / 7,064 W PTC), covering roughly 646 sq ft and saving ~$2,002/yr at 18.54 c/kWh.
How does Merlin Solar Technologies Inc FXS 100-B compare against Heliene 20M-100GH?
Merlin Solar Technologies Inc FXS 100-B outputs 100.0 W STC (15.33 V Voc, rank #21,563 of 21,677), while Heliene 20M-100GH delivers 100.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)