Merlin Solar Technologies Inc RFP-F036W180L is a 180.0 W STC (163.2 W PTC) Mono-c-Si solar module ranking #21,232 of 21,677 CEC listings (below all-CEC median; higher than 1.8% of peers). It delivers 16.51% efficiency, 24.5 V Voc at 25 C, and 26.75 V cold Voc at -10 C (22 panels max per 600 V string).
- STC Wattage
- 180.0 W
- PTC Wattage
- 163.2 W
- Voc @ 25C
- 24.5 V
- Efficiency
- 16.51%
How Does Merlin Solar Technologies Inc RFP-F036W180L Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Merlin Solar Technologies Inc RFP-F036W180L (Mono-c-Si) residential solar systems.
Homeowners evaluating Merlin Solar Technologies Inc RFP-F036W180L need 34 panels for 6 kW or 45 panels (528 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 45 panels (528 sq ft). Under NEC 690.7(A), beta_Voc (-0.262%/C) pushes open-circuit voltage to 26.75 V at 14 F and 27.39 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Merlin Solar Technologies Inc RFP-F036W180L Fall Across Listed CEC Models?
Comparison of Merlin Solar Technologies Inc RFP-F036W180L (180.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Merlin Solar Technologies Inc RFP-F036W180L?
Relative ranking of Merlin Solar Technologies Inc RFP-F036W180L across nameplate watts, 90.7% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Merlin Solar Technologies Inc RFP-F036W180L?
Summary of Merlin Solar Technologies Inc RFP-F036W180L output rank, 8 kW array size (45 panels), efficiency rating, and 600 V string limit.
180.0 W STC · Higher Than 1.8%
180.0 W STC (-205.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
16.51% Aperture Efficiency
Power density 165.1 W/m2 (3.40 percentage points below 19.91% CEC median). PTC/STC ratio: 90.7% (rank #17,330).
22 Panels Max @ -10 C (600 V)
Cold Voc reaches 26.75 V at -10 C (588.5 V string) and 27.39 V at -20 C (21 max).
45 Panels = 8,100 W STC
Occupies 49.1 m2 (528 sq ft) producing 7,344 W PTC; NEC 690.8 OCPD floor is 14.35 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 24.5 * (1 + (-0.262/100) * (-10 - 25)) = 26.75 V | OCPD = 1.56 * 9.2 = 14.35 A
Inputs from CEC Modules.csv for Merlin Solar Technologies Inc RFP-F036W180L: Voc=24.5 V, beta_Voc=-0.262%/C, Isc=9.2 A, STC=180.0 W, Area=1.09 m2.
Result: 22 panels max on 600 V (588.5 V); 45 panels for 8 kW (528 sq ft).
What Are the Published CEC Specifications for Merlin Solar Technologies Inc RFP-F036W180L?
Complete CEC test sheet for Merlin Solar Technologies Inc RFP-F036W180L including Isc (9.2 A), Voc (24.5 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 180.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 163.2 W (90.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 24.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.2 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 20.5 V / 8.77 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.262 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.51% (1.09 m2) | Array roof footprint density |
| Cell Count & Technology | 36 cells (Mono-c-Si) | Monofacial backsheet |
How Many Merlin Solar Technologies Inc RFP-F036W180L Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Merlin Solar Technologies Inc RFP-F036W180L.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 34 | 6.12 kW | 399 sq ft | $1,532 | $2,590 |
| 8 kW Class | 45 | 8.1 kW | 528 sq ft | $2,027 | $3,428 |
| 10 kW Class | 56 | 10.08 kW | 657 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Merlin Solar Technologies Inc Series?
Related Merlin Solar Technologies Inc power steps and black/silver trims consolidated into this Merlin Solar Technologies Inc RFP-F036W180L series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Merlin Solar Technologies Inc RFP-F036W175L | 175.0 W | 158.6 W | 24.4 V | 20.2 V | 16.06% |
| Merlin Solar Technologies Inc RFP-F036W180L | 180.0 W | 163.2 W | 24.5 V | 20.5 V | 16.51% |
| Merlin Solar Technologies Inc RFP-F036W185L | 185.0 W | 167.9 W | 24.5 V | 20.9 V | 16.97% |
How Many Merlin Solar Technologies Inc RFP-F036W180L Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Merlin Solar Technologies Inc RFP-F036W180L (24.5 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 27.39 V | 21 panels | 575.2 V | 36 panels |
| -10 C (14 F) | 26.75 V | 22 panels | 588.5 V | 37 panels |
| 0 C (32 F) | 26.1 V | 22 panels | 574.2 V | 38 panels |
| 25 C (77 F STC) | 24.5 V | 24 panels | 588.0 V | 40 panels |
Which Cross-Brand Solar Modules Compare Closest to Merlin Solar Technologies Inc RFP-F036W180L?
Four comparable CEC modules such as Grenzebach Envelon GmbH ON Generate-36-S1 (185.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Grenzebach Envelon GmbH ON Generate-36-S1 Grenzebach Envelon GmbH |
185.0 W | +5.0 W | 24.28 V | 16.37% | 91.0% |
| Walters & Wolf Glass Co VL-C300-1-0904-175W-M Walters & Wolf Glass Co |
175.0 W | -5.0 W | 25.03 V | 15.49% | 92.9% |
| Trina Solar TSM-175PEG4007 Trina Solar |
175.0 W | -5.0 W | 25.4 V | 10.64% | 88.1% |
| Guangdong Golden Glass Technologies GG180M2-24/1324x992 Guangdong Golden Glass Technologies |
180.0 W | Tie (0 W) | 29.4 V | 13.7% | 89.9% |
What Are the Design Limits and Best-Fit Uses for Merlin Solar Technologies Inc RFP-F036W180L?
Evaluate Merlin Solar Technologies Inc RFP-F036W180L (180.0 W STC, 24.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Merlin Solar Technologies Inc RFP-F036W180L reaches 27.39 V per panel—exceeding 21 panels in series voids 600 V inverter warranties.
- Footprint constraint: 45 panels for an 8 kW build require 528 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 45 panels (528 sq ft).
- 2026 tax credit baseline: cash residential installs of Merlin Solar Technologies Inc RFP-F036W180L carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Merlin Solar Technologies Inc RFP-F036W180L 8 kW Residential Fit
Needs 45 modules (528 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 22 panels (-10 C) or 21 panels (-20 C), or compare Grenzebach Envelon GmbH ON Generate-36-S1.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 163.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Merlin Solar Technologies Inc RFP-F036W180L by Merlin Solar Technologies Inc grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Merlin Solar Technologies Inc RFP-F036W180L PTC wattage (163.2 W) lower than STC (180.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 163.2 W PTC (90.7% retention) across Merlin Solar Technologies Inc RFP-F036W180L's 1.09 m2 aperture.
Who should skip Merlin Solar Technologies Inc RFP-F036W180L on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 45 Merlin Solar Technologies Inc RFP-F036W180L panels (528 sq ft) leave unusable roof gaps vs. Grenzebach Envelon GmbH ON Generate-36-S1.
What is the 1,000 V commercial string limit for Merlin Solar Technologies Inc RFP-F036W180L?
On 1,000 V commercial inverters at -10 C (26.75 V cold Voc), Merlin Solar Technologies Inc RFP-F036W180L fits up to 37 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)