Walters & Wolf Glass Co VL-C300-1-0904-175W-M is a 175.0 W STC (162.6 W PTC) Mono-c-Si solar module ranking #21,282 of 21,677 CEC listings (below all-CEC median; higher than 1.6% of peers). It delivers 15.49% efficiency, 25.03 V Voc at 25 C, and 27.35 V cold Voc at -10 C (21 panels max per 600 V string).
- STC Wattage
- 175.0 W
- PTC Wattage
- 162.6 W
- Voc @ 25C
- 25.03 V
- Efficiency
- 15.49%
How Does Walters & Wolf Glass Co VL-C300-1-0904-175W-M Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Walters & Wolf Glass Co VL-C300-1-0904-175W-M (Mono-c-Si) residential solar systems.
Homeowners evaluating Walters & Wolf Glass Co VL-C300-1-0904-175W-M need 35 panels for 6 kW or 46 panels (560 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 46 panels (560 sq ft). Under NEC 690.7(A), beta_Voc (-0.265%/C) pushes open-circuit voltage to 27.35 V at 14 F and 28.01 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Walters & Wolf Glass Co VL-C300-1-0904-175W-M Fall Across Listed CEC Models?
Comparison of Walters & Wolf Glass Co VL-C300-1-0904-175W-M (175.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Walters & Wolf Glass Co VL-C300-1-0904-175W-M?
Relative ranking of Walters & Wolf Glass Co VL-C300-1-0904-175W-M across nameplate watts, 92.9% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Walters & Wolf Glass Co VL-C300-1-0904-175W-M?
Summary of Walters & Wolf Glass Co VL-C300-1-0904-175W-M output rank, 8 kW array size (46 panels), efficiency rating, and 600 V string limit.
175.0 W STC · Higher Than 1.6%
175.0 W STC (-210.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
15.49% Aperture Efficiency
Power density 154.9 W/m2 (4.42 percentage points below 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).
21 Panels Max @ -10 C (600 V)
Cold Voc reaches 27.35 V at -10 C (574.4 V string) and 28.01 V at -20 C (21 max).
46 Panels = 8,050 W STC
Occupies 52.0 m2 (560 sq ft) producing 7,480 W PTC; NEC 690.8 OCPD floor is 14.13 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 25.03 * (1 + (-0.265/100) * (-10 - 25)) = 27.35 V | OCPD = 1.56 * 9.06 = 14.13 A
Inputs from CEC Modules.csv for Walters & Wolf Glass Co VL-C300-1-0904-175W-M: Voc=25.03 V, beta_Voc=-0.265%/C, Isc=9.06 A, STC=175.0 W, Area=1.13 m2.
Result: 21 panels max on 600 V (574.4 V); 46 panels for 8 kW (560 sq ft).
What Are the Published CEC Specifications for Walters & Wolf Glass Co VL-C300-1-0904-175W-M?
Complete CEC test sheet for Walters & Wolf Glass Co VL-C300-1-0904-175W-M including Isc (9.06 A), Voc (25.03 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 175.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 162.6 W (92.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 25.03 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.06 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 21.6 V / 8.31 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.265 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.49% (1.13 m2) | Array roof footprint density |
| Cell Count & Technology | 36 cells (Mono-c-Si) | Monofacial backsheet |
How Many Walters & Wolf Glass Co VL-C300-1-0904-175W-M Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Walters & Wolf Glass Co VL-C300-1-0904-175W-M.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 35 | 6.12 kW | 426 sq ft | $1,532 | $2,590 |
| 8 kW Class | 46 | 8.05 kW | 560 sq ft | $2,015 | $3,407 |
| 10 kW Class | 58 | 10.15 kW | 705 sq ft | $2,540 | $4,296 |
How Many Walters & Wolf Glass Co VL-C300-1-0904-175W-M Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Walters & Wolf Glass Co VL-C300-1-0904-175W-M (25.03 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 28.01 V | 21 panels | 588.2 V | 35 panels |
| -10 C (14 F) | 27.35 V | 21 panels | 574.4 V | 36 panels |
| 0 C (32 F) | 26.69 V | 22 panels | 587.2 V | 37 panels |
| 25 C (77 F STC) | 25.03 V | 23 panels | 575.7 V | 39 panels |
Which Cross-Brand Solar Modules Compare Closest to Walters & Wolf Glass Co VL-C300-1-0904-175W-M?
Four comparable CEC modules such as Trina Solar TSM-175PEG4007 (175.0 W) for side-by-side solar quote checks. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Trina Solar TSM-175PEG4007 Trina Solar |
175.0 W | Tie (0 W) | 25.4 V | 10.64% | 88.1% |
| Merlin Solar Technologies Inc RFP-F036B180L Merlin Solar Technologies Inc |
180.0 W | +5.0 W | 24.52 V | 16.51% | 89.7% |
| Merlin Solar Technologies Inc RFP-F036B180S Merlin Solar Technologies Inc |
180.0 W | +5.0 W | 24.52 V | 16.51% | 89.7% |
| Merlin Solar Technologies Inc RFP-F036W180L Merlin Solar Technologies Inc |
180.0 W | +5.0 W | 24.5 V | 16.51% | 90.7% |
What Are the Design Limits and Best-Fit Uses for Walters & Wolf Glass Co VL-C300-1-0904-175W-M?
Evaluate Walters & Wolf Glass Co VL-C300-1-0904-175W-M (175.0 W STC, 25.03 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Walters & Wolf Glass Co VL-C300-1-0904-175W-M reaches 28.01 V per panel—exceeding 21 panels in series voids 600 V inverter warranties.
- Footprint constraint: 46 panels for an 8 kW build require 560 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 46 panels (560 sq ft).
- 2026 tax credit baseline: cash residential installs of Walters & Wolf Glass Co VL-C300-1-0904-175W-M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Walters & Wolf Glass Co VL-C300-1-0904-175W-M 8 kW Residential Fit
Needs 46 modules (560 sq ft) with a 15 A string OCPD, offsetting ~$2,015/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 21 panels (-10 C) or 21 panels (-20 C), or compare Trina Solar TSM-175PEG4007.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 162.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Walters & Wolf Glass Co VL-C300-1-0904-175W-M by Walters & Wolf Glass Co grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Walters & Wolf Glass Co VL-C300-1-0904-175W-M PTC wattage (162.6 W) lower than STC (175.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 162.6 W PTC (92.9% retention) across Walters & Wolf Glass Co VL-C300-1-0904-175W-M's 1.13 m2 aperture.
Who should skip Walters & Wolf Glass Co VL-C300-1-0904-175W-M on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 46 Walters & Wolf Glass Co VL-C300-1-0904-175W-M panels (560 sq ft) leave unusable roof gaps vs. Trina Solar TSM-175PEG4007.
What is the 1,000 V commercial string limit for Walters & Wolf Glass Co VL-C300-1-0904-175W-M?
On 1,000 V commercial inverters at -10 C (27.35 V cold Voc), Walters & Wolf Glass Co VL-C300-1-0904-175W-M fits up to 36 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)