Skip to main content
WireAndSun
Calculators
CEC PV Module

Merlin Solar Technologies Inc RFP-F036B180S — CEC Solar Module Specifications

Manufacturer: Merlin Solar Technologies Inc Registry: CEC Verified Engineering Specification

Merlin Solar Technologies Inc RFP-F036B180S is a 180.0 W STC (161.4 W PTC) Mono-c-Si solar module ranking #21,232 of 21,677 CEC listings (below all-CEC median; higher than 1.8% of peers). It delivers 16.51% efficiency, 24.52 V Voc at 25 C, and 26.8 V cold Voc at -10 C (22 panels max per 600 V string).

STC Wattage
180.0 W
PTC Wattage
161.4 W
Voc @ 25C
24.52 V
Efficiency
16.51%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Merlin Solar Technologies Inc RFP-F036B180S Compare Against Peer CEC Listings?

Engineering position of Merlin Solar Technologies Inc RFP-F036B180S (180.0 W STC) vs. Grenzebach Envelon GmbH ON Generate-36-S1 across 5,889 CEC Mono-c-Si solar modules.

Built with 36 Mono-c-Si cells, Merlin Solar Technologies Inc RFP-F036B180S pairs typical 89.7% PTC-to-STC thermal output (161.4 W real-world rating) with 24.52 V nominal Voc. An 8 kW residential build (8,100 W DC, 7,263 W PTC) saves ~$2,027/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Grenzebach Envelon GmbH ON Generate-36-S1 offers a 185.0 W alternative.

Where Does Merlin Solar Technologies Inc RFP-F036B180S Fall Across Listed CEC Models?

Plots Merlin Solar Technologies Inc RFP-F036B180S at 180.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Merlin Solar Technologies Inc RFP-F036B180S (180.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCMerlin Solar Techn: 180.0 W

What Dataset Percentiles Define Merlin Solar Technologies Inc RFP-F036B180S?

Benchmarks Merlin Solar Technologies Inc RFP-F036B180S on STC wattage, thermal PTC/STC retention, and 16.51 aperture conversion efficiency against CEC peers.

Merlin Solar Technologies Inc RFP-F036B180S Engineering BenchmarksPercentile comparison of Merlin Solar Technologies Inc RFP-F036B180S wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage180.0 WPTC/STC Retention89.7%Module Efficiency16.51%

What Do the Dataset Ranks Show for Merlin Solar Technologies Inc RFP-F036B180S?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Merlin Solar Technologies Inc RFP-F036B180S by Merlin Solar Technologies Inc.

Rank #21,232 / 21,677

180.0 W STC · Higher Than 1.8%

180.0 W STC (-205.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #17,253

16.51% Aperture Efficiency

Power density 165.1 W/m2 (3.40 percentage points below 19.91% CEC median). PTC/STC ratio: 89.7% (rank #19,653).

NEC 690.7 Limit

22 Panels Max @ -10 C (600 V)

Cold Voc reaches 26.8 V at -10 C (589.6 V string) and 27.46 V at -20 C (21 max).

8 kW Reference Array

45 Panels = 8,100 W STC

Occupies 49.1 m2 (528 sq ft) producing 7,263 W PTC; NEC 690.8 OCPD floor is 14.15 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 24.52 * (1 + (-0.266/100) * (-10 - 25)) = 26.8 V | OCPD = 1.56 * 9.07 = 14.15 A

Inputs from CEC Modules.csv for Merlin Solar Technologies Inc RFP-F036B180S: Voc=24.52 V, beta_Voc=-0.266%/C, Isc=9.07 A, STC=180.0 W, Area=1.09 m2.

Result: 22 panels max on 600 V (589.6 V); 45 panels for 8 kW (528 sq ft).

What Are the Published CEC Specifications for Merlin Solar Technologies Inc RFP-F036B180S?

Laboratory test ratings recorded for Merlin Solar Technologies Inc RFP-F036B180S (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Merlin Solar Technologies Inc RFP-F036B180S.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 180.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 161.4 W (89.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 24.52 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.07 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 20.72 V / 8.69 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.266 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.51% (1.09 m2) Array roof footprint density
Cell Count & Technology 36 cells (Mono-c-Si) Monofacial backsheet

How Many Merlin Solar Technologies Inc RFP-F036B180S Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (528 sq ft at 8 kW), and estimated Year-1 electric bill offset for Merlin Solar Technologies Inc RFP-F036B180S.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 34 6.12 kW 399 sq ft $1,532 $2,590
8 kW Class 45 8.1 kW 528 sq ft $2,027 $3,428
10 kW Class 56 10.08 kW 657 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This Merlin Solar Technologies Inc Series?

Sibling wattage bins and frame colors grouped with Merlin Solar Technologies Inc RFP-F036B180S under Merlin Solar Technologies Inc to prevent duplicate spec pages.

Sibling CEC listings grouped into the Merlin Solar Technologies Inc RFP-F036B180S wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Merlin Solar Technologies Inc RFP-F036B175S 175.0 W 156.8 W 24.45 V 20.4 V 16.06%
Merlin Solar Technologies Inc RFP-F036B180S 180.0 W 161.4 W 24.52 V 20.72 V 16.51%

How Many Merlin Solar Technologies Inc RFP-F036B180S Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Merlin Solar Technologies Inc RFP-F036B180S (beta_Voc -0.266%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=24.52V and beta_Voc=-0.266%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 27.46 V 21 panels 576.7 V 36 panels
-10 C (14 F) 26.8 V 22 panels 589.6 V 37 panels
0 C (32 F) 26.15 V 22 panels 575.3 V 38 panels
25 C (77 F STC) 24.52 V 24 panels 588.5 V 40 panels

Which Cross-Brand Solar Modules Compare Closest to Merlin Solar Technologies Inc RFP-F036B180S?

Closest cross-brand CEC competitors to Merlin Solar Technologies Inc RFP-F036B180S matched near 180.0 W STC and 24.52 V Voc, led by Grenzebach Envelon GmbH ON Generate-36-S1.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Grenzebach Envelon GmbH ON Generate-36-S1
Grenzebach Envelon GmbH
185.0 W +5.0 W 24.28 V 16.37% 91.0%
Walters & Wolf Glass Co VL-C300-1-0904-175W-M
Walters & Wolf Glass Co
175.0 W -5.0 W 25.03 V 15.49% 92.9%
Trina Solar TSM-175PEG4007
Trina Solar
175.0 W -5.0 W 25.4 V 10.64% 88.1%
Guangdong Golden Glass Technologies GG180M2-24/1324x992
Guangdong Golden Glass Technologies
180.0 W Tie (0 W) 29.4 V 13.7% 89.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Merlin Solar Technologies Inc RFP-F036B180S?

Evaluate Merlin Solar Technologies Inc RFP-F036B180S (180.0 W STC, 24.52 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Merlin Solar Technologies Inc RFP-F036B180S reaches 27.46 V per panel—exceeding 21 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 45 panels for an 8 kW build require 528 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 45 panels (528 sq ft).
  • 2026 tax credit baseline: cash residential installs of Merlin Solar Technologies Inc RFP-F036B180S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Merlin Solar Technologies Inc RFP-F036B180S 8 kW Residential Fit

Needs 45 modules (528 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 22 panels (-10 C) or 21 panels (-20 C), or compare Grenzebach Envelon GmbH ON Generate-36-S1.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 161.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Merlin Solar Technologies Inc RFP-F036B180S by Merlin Solar Technologies Inc grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Merlin Solar Technologies Inc RFP-F036B180S?

Multiplying Merlin Solar Technologies Inc RFP-F036B180S's 9.07 A short-circuit current by 1.56 equals 14.15 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Merlin Solar Technologies Inc RFP-F036B180S pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 26.8 V cold Voc at 14 F and handles 9.07 A Isc; string inverters cap Merlin Solar Technologies Inc RFP-F036B180S at 22 panels on 600 V.

Is Merlin Solar Technologies Inc RFP-F036B180S eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Merlin Solar Technologies Inc RFP-F036B180S rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.