Merlin Solar Technologies Inc RFP-F036B180S is a 180.0 W STC (161.4 W PTC) Mono-c-Si solar module ranking #21,232 of 21,677 CEC listings (below all-CEC median; higher than 1.8% of peers). It delivers 16.51% efficiency, 24.52 V Voc at 25 C, and 26.8 V cold Voc at -10 C (22 panels max per 600 V string).
- STC Wattage
- 180.0 W
- PTC Wattage
- 161.4 W
- Voc @ 25C
- 24.52 V
- Efficiency
- 16.51%
How Does Merlin Solar Technologies Inc RFP-F036B180S Compare Against Peer CEC Listings?
Engineering position of Merlin Solar Technologies Inc RFP-F036B180S (180.0 W STC) vs. Grenzebach Envelon GmbH ON Generate-36-S1 across 5,889 CEC Mono-c-Si solar modules.
Built with 36 Mono-c-Si cells, Merlin Solar Technologies Inc RFP-F036B180S pairs typical 89.7% PTC-to-STC thermal output (161.4 W real-world rating) with 24.52 V nominal Voc. An 8 kW residential build (8,100 W DC, 7,263 W PTC) saves ~$2,027/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Grenzebach Envelon GmbH ON Generate-36-S1 offers a 185.0 W alternative.
Where Does Merlin Solar Technologies Inc RFP-F036B180S Fall Across Listed CEC Models?
Plots Merlin Solar Technologies Inc RFP-F036B180S at 180.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Merlin Solar Technologies Inc RFP-F036B180S?
Benchmarks Merlin Solar Technologies Inc RFP-F036B180S on STC wattage, thermal PTC/STC retention, and 16.51 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Merlin Solar Technologies Inc RFP-F036B180S?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Merlin Solar Technologies Inc RFP-F036B180S by Merlin Solar Technologies Inc.
180.0 W STC · Higher Than 1.8%
180.0 W STC (-205.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
16.51% Aperture Efficiency
Power density 165.1 W/m2 (3.40 percentage points below 19.91% CEC median). PTC/STC ratio: 89.7% (rank #19,653).
22 Panels Max @ -10 C (600 V)
Cold Voc reaches 26.8 V at -10 C (589.6 V string) and 27.46 V at -20 C (21 max).
45 Panels = 8,100 W STC
Occupies 49.1 m2 (528 sq ft) producing 7,263 W PTC; NEC 690.8 OCPD floor is 14.15 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 24.52 * (1 + (-0.266/100) * (-10 - 25)) = 26.8 V | OCPD = 1.56 * 9.07 = 14.15 A
Inputs from CEC Modules.csv for Merlin Solar Technologies Inc RFP-F036B180S: Voc=24.52 V, beta_Voc=-0.266%/C, Isc=9.07 A, STC=180.0 W, Area=1.09 m2.
Result: 22 panels max on 600 V (589.6 V); 45 panels for 8 kW (528 sq ft).
What Are the Published CEC Specifications for Merlin Solar Technologies Inc RFP-F036B180S?
Laboratory test ratings recorded for Merlin Solar Technologies Inc RFP-F036B180S (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 180.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 161.4 W (89.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 24.52 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.07 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 20.72 V / 8.69 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.266 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.51% (1.09 m2) | Array roof footprint density |
| Cell Count & Technology | 36 cells (Mono-c-Si) | Monofacial backsheet |
How Many Merlin Solar Technologies Inc RFP-F036B180S Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (528 sq ft at 8 kW), and estimated Year-1 electric bill offset for Merlin Solar Technologies Inc RFP-F036B180S.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 34 | 6.12 kW | 399 sq ft | $1,532 | $2,590 |
| 8 kW Class | 45 | 8.1 kW | 528 sq ft | $2,027 | $3,428 |
| 10 kW Class | 56 | 10.08 kW | 657 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Merlin Solar Technologies Inc Series?
Sibling wattage bins and frame colors grouped with Merlin Solar Technologies Inc RFP-F036B180S under Merlin Solar Technologies Inc to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Merlin Solar Technologies Inc RFP-F036B175S | 175.0 W | 156.8 W | 24.45 V | 20.4 V | 16.06% |
| Merlin Solar Technologies Inc RFP-F036B180S | 180.0 W | 161.4 W | 24.52 V | 20.72 V | 16.51% |
How Many Merlin Solar Technologies Inc RFP-F036B180S Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Merlin Solar Technologies Inc RFP-F036B180S (beta_Voc -0.266%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 27.46 V | 21 panels | 576.7 V | 36 panels |
| -10 C (14 F) | 26.8 V | 22 panels | 589.6 V | 37 panels |
| 0 C (32 F) | 26.15 V | 22 panels | 575.3 V | 38 panels |
| 25 C (77 F STC) | 24.52 V | 24 panels | 588.5 V | 40 panels |
Which Cross-Brand Solar Modules Compare Closest to Merlin Solar Technologies Inc RFP-F036B180S?
Closest cross-brand CEC competitors to Merlin Solar Technologies Inc RFP-F036B180S matched near 180.0 W STC and 24.52 V Voc, led by Grenzebach Envelon GmbH ON Generate-36-S1.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Grenzebach Envelon GmbH ON Generate-36-S1 Grenzebach Envelon GmbH |
185.0 W | +5.0 W | 24.28 V | 16.37% | 91.0% |
| Walters & Wolf Glass Co VL-C300-1-0904-175W-M Walters & Wolf Glass Co |
175.0 W | -5.0 W | 25.03 V | 15.49% | 92.9% |
| Trina Solar TSM-175PEG4007 Trina Solar |
175.0 W | -5.0 W | 25.4 V | 10.64% | 88.1% |
| Guangdong Golden Glass Technologies GG180M2-24/1324x992 Guangdong Golden Glass Technologies |
180.0 W | Tie (0 W) | 29.4 V | 13.7% | 89.9% |
What Are the Design Limits and Best-Fit Uses for Merlin Solar Technologies Inc RFP-F036B180S?
Evaluate Merlin Solar Technologies Inc RFP-F036B180S (180.0 W STC, 24.52 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Merlin Solar Technologies Inc RFP-F036B180S reaches 27.46 V per panel—exceeding 21 panels in series voids 600 V inverter warranties.
- Footprint constraint: 45 panels for an 8 kW build require 528 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 45 panels (528 sq ft).
- 2026 tax credit baseline: cash residential installs of Merlin Solar Technologies Inc RFP-F036B180S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Merlin Solar Technologies Inc RFP-F036B180S 8 kW Residential Fit
Needs 45 modules (528 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 22 panels (-10 C) or 21 panels (-20 C), or compare Grenzebach Envelon GmbH ON Generate-36-S1.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 161.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Merlin Solar Technologies Inc RFP-F036B180S by Merlin Solar Technologies Inc grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Merlin Solar Technologies Inc RFP-F036B180S?
Multiplying Merlin Solar Technologies Inc RFP-F036B180S's 9.07 A short-circuit current by 1.56 equals 14.15 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Merlin Solar Technologies Inc RFP-F036B180S pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 26.8 V cold Voc at 14 F and handles 9.07 A Isc; string inverters cap Merlin Solar Technologies Inc RFP-F036B180S at 22 panels on 600 V.
Is Merlin Solar Technologies Inc RFP-F036B180S eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Merlin Solar Technologies Inc RFP-F036B180S rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)