Skip to main content
WireAndSun
Calculators
CEC PV Module

SunTegra STS-114M-B4U — CEC Solar Module Specifications

Manufacturer: SunTegra Registry: CEC Verified Engineering Specification

SunTegra STS-114M-B4U is a 114.0 W STC (98.9 W PTC) Mono-c-Si solar module ranking #21,518 of 21,677 CEC listings (below all-CEC median; higher than 0.7% of peers). It delivers 17.27% efficiency, 15.52 V Voc at 25 C, and 17.1 V cold Voc at -10 C (35 panels max per 600 V string).

STC Wattage
114.0 W
PTC Wattage
98.9 W
Voc @ 25C
15.52 V
Efficiency
17.27%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SunTegra STS-114M-B4U Compare Against Peer CEC Listings?

Engineering position of SunTegra STS-114M-B4U (114.0 W STC) vs. Merlin Solar Technologies Inc FX110 across 5,889 CEC Mono-c-Si solar modules.

Ranking #21,518 across 21,677 CEC solar panels (below all-CEC median; higher than 0.7% of peers), SunTegra STS-114M-B4U operates as a compact residential or specialty off-grid module sitting 296.0 W below the 410.0 W Mono-c-Si median. Lower 15.52 V string voltage fits 35 panels in series at 14 F and pairs easily with microinverters. With typical 86.8% PTC-to-STC thermal output (98.9 W real-world rating), 71 panels occupy 504 sq ft and offset roughly $2,025/yr at average US rates (or $3,424/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does SunTegra STS-114M-B4U Fall Across Listed CEC Models?

Plots SunTegra STS-114M-B4U at 114.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SunTegra STS-114M-B4U (114.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSunTegra STS-114M-: 114.0 W

What Dataset Percentiles Define SunTegra STS-114M-B4U?

Benchmarks SunTegra STS-114M-B4U on STC wattage, thermal PTC/STC retention, and 17.27 aperture conversion efficiency against CEC peers.

SunTegra STS-114M-B4U Engineering BenchmarksPercentile comparison of SunTegra STS-114M-B4U wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage114.0 WPTC/STC Retention86.8%Module Efficiency17.27%

What Do the Dataset Ranks Show for SunTegra STS-114M-B4U?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for SunTegra STS-114M-B4U by SunTegra.

Rank #21,518 / 21,677

114.0 W STC · Higher Than 0.7%

114.0 W STC (-271.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #16,091

17.27% Aperture Efficiency

Power density 172.7 W/m2 (2.64 percentage points below 19.91% CEC median). PTC/STC ratio: 86.8% (rank #21,603).

NEC 690.7 Limit

35 Panels Max @ -10 C (600 V)

Cold Voc reaches 17.1 V at -10 C (598.5 V string) and 17.55 V at -20 C (34 max).

8 kW Reference Array

71 Panels = 8,094 W STC

Occupies 46.9 m2 (504 sq ft) producing 7,022 W PTC; NEC 690.8 OCPD floor is 15.1 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 15.52 * (1 + (-0.291/100) * (-10 - 25)) = 17.1 V | OCPD = 1.56 * 9.68 = 15.1 A

Inputs from CEC Modules.csv for SunTegra STS-114M-B4U: Voc=15.52 V, beta_Voc=-0.291%/C, Isc=9.68 A, STC=114.0 W, Area=0.66 m2.

Result: 35 panels max on 600 V (598.5 V); 71 panels for 8 kW (504 sq ft).

What Are the Published CEC Specifications for SunTegra STS-114M-B4U?

Laboratory test ratings recorded for SunTegra STS-114M-B4U (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for SunTegra STS-114M-B4U.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 114.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 98.9 W (86.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 15.52 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.68 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 12.78 V / 8.92 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.291 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.27% (0.66 m2) Array roof footprint density
Cell Count & Technology 24 cells (Mono-c-Si) Monofacial backsheet

How Many SunTegra STS-114M-B4U Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (504 sq ft at 8 kW), and estimated Year-1 electric bill offset for SunTegra STS-114M-B4U.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 53 6.04 kW 377 sq ft $1,512 $2,556
8 kW Class 71 8.09 kW 504 sq ft $2,025 $3,424
10 kW Class 88 10.03 kW 625 sq ft $2,510 $4,245

Which Sibling Wattage & Trim Variants Belong to This SunTegra Series?

Sibling wattage bins and frame colors grouped with SunTegra STS-114M-B4U under SunTegra to prevent duplicate spec pages. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the SunTegra STS-114M-B4U wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
SunTegra STS-110M-B4U 110.0 W 95.3 W 15.46 V 12.72 V 16.67%
SunTegra STS-114M-B4U 114.0 W 98.9 W 15.52 V 12.78 V 17.27%

How Many SunTegra STS-114M-B4U Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for SunTegra STS-114M-B4U (beta_Voc -0.291%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=15.52V and beta_Voc=-0.291%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 17.55 V 34 panels 596.7 V 56 panels
-10 C (14 F) 17.1 V 35 panels 598.5 V 58 panels
0 C (32 F) 16.65 V 36 panels 599.4 V 60 panels
25 C (77 F STC) 15.52 V 38 panels 589.8 V 64 panels

Which Cross-Brand Solar Modules Compare Closest to SunTegra STS-114M-B4U?

Closest cross-brand CEC competitors to SunTegra STS-114M-B4U matched near 114.0 W STC and 15.52 V Voc, led by Merlin Solar Technologies Inc FX110.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Merlin Solar Technologies Inc FX110
Merlin Solar Technologies Inc
110.0 W -4.0 W 15.6 V 14.53% 91.5%
Merlin Solar Technologies Inc RFP-F024B117L
Merlin Solar Technologies Inc
117.0 W +3.0 W 16.3 V 15.39% 89.5%
SunStyle M110 870
SunStyle
110.0 W -4.0 W 16.1 V 14.47% 89.3%
Merlin Solar Technologies Inc FXS 105-W
Merlin Solar Technologies Inc
105.0 W -9.0 W 15.5 V 14.0% 91.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SunTegra STS-114M-B4U?

Evaluate SunTegra STS-114M-B4U (114.0 W STC, 15.52 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SunTegra STS-114M-B4U reaches 17.55 V per panel—exceeding 34 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 71 panels for an 8 kW build require 504 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 71 panels (504 sq ft).
  • 2026 tax credit baseline: cash residential installs of SunTegra STS-114M-B4U carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SunTegra STS-114M-B4U 8 kW Residential Fit

Needs 71 modules (504 sq ft) with a 20 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 35 panels (-10 C) or 34 panels (-20 C), or compare Merlin Solar Technologies Inc FX110.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 98.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SunTegra STS-114M-B4U by SunTegra grounded in CEC test data and NEC 690.7/690.8 limits. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

How many SunTegra STS-114M-B4U panels fit on a 600 V winter solar string?

At -10 C (14 F), SunTegra STS-114M-B4U cold Voc rises from 15.52 V to 17.1 V (beta_Voc -0.291%/C), capping a 600 V string at 35 panels (598.5 V).

How much roof area does an 8 kW array of SunTegra STS-114M-B4U need?

An 8 kW DC system uses 71 SunTegra STS-114M-B4U modules (8,094 W STC / 7,022 W PTC), covering roughly 504 sq ft and saving ~$2,025/yr at 18.54 c/kWh.

How does SunTegra STS-114M-B4U compare against Merlin Solar Technologies Inc FX110?

SunTegra STS-114M-B4U outputs 114.0 W STC (15.52 V Voc, rank #21,518 of 21,677), while Merlin Solar Technologies Inc FX110 delivers 110.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.