Skip to main content
WireAndSun
Calculators
CEC PV Module

Merlin Solar Technologies Inc RFP-F024B117L — CEC Solar Module Specifications

Manufacturer: Merlin Solar Technologies Inc Registry: CEC Verified Engineering Specification

Merlin Solar Technologies Inc RFP-F024B117L is a 117.0 W STC (104.7 W PTC) Mono-c-Si solar module ranking #21,507 of 21,677 CEC listings (below all-CEC median; higher than 0.8% of peers). It delivers 15.39% efficiency, 16.3 V Voc at 25 C, and 17.82 V cold Voc at -10 C (33 panels max per 600 V string).

STC Wattage
117.0 W
PTC Wattage
104.7 W
Voc @ 25C
16.3 V
Efficiency
15.39%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Merlin Solar Technologies Inc RFP-F024B117L Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Merlin Solar Technologies Inc RFP-F024B117L (Mono-c-Si) residential solar systems.

Homeowners evaluating Merlin Solar Technologies Inc RFP-F024B117L need 52 panels for 6 kW or 69 panels (564 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 69 panels (564 sq ft). Under NEC 690.7(A), beta_Voc (-0.266%/C) pushes open-circuit voltage to 17.82 V at 14 F and 18.25 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Merlin Solar Technologies Inc RFP-F024B117L Fall Across Listed CEC Models?

Comparison of Merlin Solar Technologies Inc RFP-F024B117L (117.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Merlin Solar Technologies Inc RFP-F024B117L (117.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCMerlin Solar Techn: 117.0 W

What Dataset Percentiles Define Merlin Solar Technologies Inc RFP-F024B117L?

Relative ranking of Merlin Solar Technologies Inc RFP-F024B117L across nameplate watts, 89.5% PTC thermal ratio, and module aperture efficiency.

Merlin Solar Technologies Inc RFP-F024B117L Engineering BenchmarksPercentile comparison of Merlin Solar Technologies Inc RFP-F024B117L wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage117.0 WPTC/STC Retention89.5%Module Efficiency15.39%

What Do the Dataset Ranks Show for Merlin Solar Technologies Inc RFP-F024B117L?

Summary of Merlin Solar Technologies Inc RFP-F024B117L output rank, 8 kW array size (69 panels), efficiency rating, and 600 V string limit.

Rank #21,507 / 21,677

117.0 W STC · Higher Than 0.8%

117.0 W STC (-268.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #19,139

15.39% Aperture Efficiency

Power density 153.9 W/m2 (4.52 percentage points below 19.91% CEC median). PTC/STC ratio: 89.5% (rank #19,939).

NEC 690.7 Limit

33 Panels Max @ -10 C (600 V)

Cold Voc reaches 17.82 V at -10 C (588.1 V string) and 18.25 V at -20 C (32 max).

8 kW Reference Array

69 Panels = 8,073 W STC

Occupies 52.4 m2 (564 sq ft) producing 7,224 W PTC; NEC 690.8 OCPD floor is 14.07 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 16.3 * (1 + (-0.266/100) * (-10 - 25)) = 17.82 V | OCPD = 1.56 * 9.02 = 14.07 A

Inputs from CEC Modules.csv for Merlin Solar Technologies Inc RFP-F024B117L: Voc=16.3 V, beta_Voc=-0.266%/C, Isc=9.02 A, STC=117.0 W, Area=0.76 m2.

Result: 33 panels max on 600 V (588.1 V); 69 panels for 8 kW (564 sq ft).

What Are the Published CEC Specifications for Merlin Solar Technologies Inc RFP-F024B117L?

Complete CEC test sheet for Merlin Solar Technologies Inc RFP-F024B117L including Isc (9.02 A), Voc (16.3 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Merlin Solar Technologies Inc RFP-F024B117L.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 117.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 104.7 W (89.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 16.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.02 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 13.62 V / 8.59 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.266 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.39% (0.76 m2) Array roof footprint density
Cell Count & Technology 24 cells (Mono-c-Si) Monofacial backsheet

How Many Merlin Solar Technologies Inc RFP-F024B117L Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Merlin Solar Technologies Inc RFP-F024B117L.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 52 6.08 kW 425 sq ft $1,522 $2,573
8 kW Class 69 8.07 kW 564 sq ft $2,020 $3,415
10 kW Class 86 10.06 kW 704 sq ft $2,518 $4,258

Which Sibling Wattage & Trim Variants Belong to This Merlin Solar Technologies Inc Series?

Related Merlin Solar Technologies Inc power steps and black/silver trims consolidated into this Merlin Solar Technologies Inc RFP-F024B117L series guide.

Sibling CEC listings grouped into the Merlin Solar Technologies Inc RFP-F024B117L wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Merlin Solar Technologies Inc RFP-F024B114L 114.0 W 101.9 W 16.25 V 13.43 V 15.0%
Merlin Solar Technologies Inc RFP-F024B117L 117.0 W 104.7 W 16.3 V 13.62 V 15.39%
Merlin Solar Technologies Inc RFP-F024B120L 120.0 W 107.5 W 16.35 V 13.81 V 15.79%

How Many Merlin Solar Technologies Inc RFP-F024B117L Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Merlin Solar Technologies Inc RFP-F024B117L (16.3 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=16.3V and beta_Voc=-0.266%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 18.25 V 32 panels 584.0 V 54 panels
-10 C (14 F) 17.82 V 33 panels 588.1 V 56 panels
0 C (32 F) 17.38 V 34 panels 590.9 V 57 panels
25 C (77 F STC) 16.3 V 36 panels 586.8 V 61 panels

Which Cross-Brand Solar Modules Compare Closest to Merlin Solar Technologies Inc RFP-F024B117L?

Four comparable CEC modules such as SunTegra STS-114M-B4U (114.0 W) for side-by-side solar quote checks. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
SunTegra STS-114M-B4U
SunTegra
114.0 W -3.0 W 15.52 V 17.27% 86.8%
SunStyle M110 870
SunStyle
110.0 W -7.0 W 16.1 V 14.47% 89.3%
Solar Frame Solutions Inc SFS135T
Solar Frame Solutions Inc
135.0 W +18.0 W 16.4 V 16.46% 92.1%
WAAREE ENERGIES LIMITED WU-120
WAAREE ENERGIES LIMITED
120.0 W +3.0 W 21.0 V 12.2% 88.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Merlin Solar Technologies Inc RFP-F024B117L?

Evaluate Merlin Solar Technologies Inc RFP-F024B117L (117.0 W STC, 16.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Merlin Solar Technologies Inc RFP-F024B117L reaches 18.25 V per panel—exceeding 32 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 69 panels for an 8 kW build require 564 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 69 panels (564 sq ft).
  • 2026 tax credit baseline: cash residential installs of Merlin Solar Technologies Inc RFP-F024B117L carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Merlin Solar Technologies Inc RFP-F024B117L 8 kW Residential Fit

Needs 69 modules (564 sq ft) with a 15 A string OCPD, offsetting ~$2,020/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 33 panels (-10 C) or 32 panels (-20 C), or compare SunTegra STS-114M-B4U.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 104.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Merlin Solar Technologies Inc RFP-F024B117L by Merlin Solar Technologies Inc grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Merlin Solar Technologies Inc RFP-F024B117L PTC wattage (104.7 W) lower than STC (117.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 104.7 W PTC (89.5% retention) across Merlin Solar Technologies Inc RFP-F024B117L's 0.76 m2 aperture.

Who should skip Merlin Solar Technologies Inc RFP-F024B117L on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 69 Merlin Solar Technologies Inc RFP-F024B117L panels (564 sq ft) leave unusable roof gaps vs. SunTegra STS-114M-B4U.

What is the 1,000 V commercial string limit for Merlin Solar Technologies Inc RFP-F024B117L?

On 1,000 V commercial inverters at -10 C (17.82 V cold Voc), Merlin Solar Technologies Inc RFP-F024B117L fits up to 56 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.