Solar Frame Solutions Inc SFS135T is a 135.0 W STC (124.3 W PTC) Mono-c-Si solar module ranking #21,456 of 21,677 CEC listings (below all-CEC median; higher than 1.0% of peers). It delivers 16.46% efficiency, 16.4 V Voc at 25 C, and 17.93 V cold Voc at -10 C (33 panels max per 600 V string).
- STC Wattage
- 135.0 W
- PTC Wattage
- 124.3 W
- Voc @ 25C
- 16.4 V
- Efficiency
- 16.46%
How Does Solar Frame Solutions Inc SFS135T Compare Against Peer CEC Listings?
Solar engineering breakdown for Solar Frame Solutions Inc SFS135T: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 135.0 W STC and 124.3 W PTC, Solar Frame Solutions Inc SFS135T sits -250.0 W vs all-CEC median (below all-CEC median; higher than 1.0% of peers) among 21,677 listed modules. Power density reaches 164.6 W/m2 (3.45 percentage points below 19.91% CEC median). Lower 16.4 V string voltage fits 33 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 55 panels in series. Alternative peer Merlin Solar Technologies Inc RFP-F024W120L rates 120.0 W.
Where Does Solar Frame Solutions Inc SFS135T Fall Across Listed CEC Models?
Distribution marker showing Solar Frame Solutions Inc SFS135T (135.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Solar Frame Solutions Inc SFS135T?
Dataset percentiles tracking Solar Frame Solutions Inc SFS135T power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Solar Frame Solutions Inc SFS135T?
Benchmark highlights for Solar Frame Solutions Inc SFS135T covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
135.0 W STC · Higher Than 1.0%
135.0 W STC (-250.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
16.46% Aperture Efficiency
Power density 164.6 W/m2 (3.45 percentage points below 19.91% CEC median). PTC/STC ratio: 92.1% (rank #13,846).
33 Panels Max @ -10 C (600 V)
Cold Voc reaches 17.93 V at -10 C (591.7 V string) and 18.36 V at -20 C (32 max).
60 Panels = 8,100 W STC
Occupies 49.2 m2 (530 sq ft) producing 7,458 W PTC; NEC 690.8 OCPD floor is 16.04 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 16.4 * (1 + (-0.266/100) * (-10 - 25)) = 17.93 V | OCPD = 1.56 * 10.28 = 16.04 A
Inputs from CEC Modules.csv for Solar Frame Solutions Inc SFS135T: Voc=16.4 V, beta_Voc=-0.266%/C, Isc=10.28 A, STC=135.0 W, Area=0.82 m2.
Result: 33 panels max on 600 V (591.7 V); 60 panels for 8 kW (530 sq ft).
What Are the Published CEC Specifications for Solar Frame Solutions Inc SFS135T?
Official CEC datasheet figures for Solar Frame Solutions Inc SFS135T (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 135.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 124.3 W (92.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 16.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.28 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 13.9 V / 9.72 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.266 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.46% (0.82 m2) | Array roof footprint density |
| Cell Count & Technology | 24 cells (Mono-c-Si) | Monofacial backsheet |
How Many Solar Frame Solutions Inc SFS135T Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Solar Frame Solutions Inc SFS135T modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 45 | 6.08 kW | 397 sq ft | $1,522 | $2,573 |
| 8 kW Class | 60 | 8.1 kW | 530 sq ft | $2,027 | $3,428 |
| 10 kW Class | 75 | 10.12 kW | 662 sq ft | $2,533 | $4,283 |
How Many Solar Frame Solutions Inc SFS135T Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Solar Frame Solutions Inc SFS135T (17.93 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 18.36 V | 32 panels | 587.5 V | 54 panels |
| -10 C (14 F) | 17.93 V | 33 panels | 591.7 V | 55 panels |
| 0 C (32 F) | 17.49 V | 34 panels | 594.7 V | 57 panels |
| 25 C (77 F STC) | 16.4 V | 36 panels | 590.4 V | 60 panels |
Which Cross-Brand Solar Modules Compare Closest to Solar Frame Solutions Inc SFS135T?
Competing CEC solar panels closest to Solar Frame Solutions Inc SFS135T in nameplate wattage and Voc, starting with Merlin Solar Technologies Inc RFP-F024W120L.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Merlin Solar Technologies Inc RFP-F024W120L Merlin Solar Technologies Inc |
120.0 W | -15.0 W | 16.3 V | 15.79% | 90.6% |
| Merlin Solar Technologies Inc RFP-F024B117L Merlin Solar Technologies Inc |
117.0 W | -18.0 W | 16.3 V | 15.39% | 89.5% |
| Gintung Energy ASEC-135G6M Gintung Energy |
135.0 W | Tie (0 W) | 22.1 V | 13.74% | 89.3% |
| United Renewable Energy Co Ltd D6P135A1F United Renewable Energy Co Ltd |
135.0 W | Tie (0 W) | 22.1 V | 13.74% | 89.3% |
What Are the Design Limits and Best-Fit Uses for Solar Frame Solutions Inc SFS135T?
Evaluate Solar Frame Solutions Inc SFS135T (135.0 W STC, 16.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Solar Frame Solutions Inc SFS135T reaches 18.36 V per panel—exceeding 32 panels in series voids 600 V inverter warranties.
- Footprint constraint: 60 panels for an 8 kW build require 530 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 60 panels (530 sq ft).
- 2026 tax credit baseline: cash residential installs of Solar Frame Solutions Inc SFS135T carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Solar Frame Solutions Inc SFS135T 8 kW Residential Fit
Needs 60 modules (530 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 33 panels (-10 C) or 32 panels (-20 C), or compare Merlin Solar Technologies Inc RFP-F024W120L.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 124.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Solar Frame Solutions Inc SFS135T by Solar Frame Solutions Inc grounded in CEC test data and NEC 690.7/690.8 limits.
How many Solar Frame Solutions Inc SFS135T panels fit on a 600 V winter solar string?
At -10 C (14 F), Solar Frame Solutions Inc SFS135T cold Voc rises from 16.4 V to 17.93 V (beta_Voc -0.266%/C), capping a 600 V string at 33 panels (591.7 V).
How much roof area does an 8 kW array of Solar Frame Solutions Inc SFS135T need?
An 8 kW DC system uses 60 Solar Frame Solutions Inc SFS135T modules (8,100 W STC / 7,458 W PTC), covering roughly 530 sq ft and saving ~$2,027/yr at 18.54 c/kWh.
How does Solar Frame Solutions Inc SFS135T compare against Merlin Solar Technologies Inc RFP-F024W120L?
Solar Frame Solutions Inc SFS135T outputs 135.0 W STC (16.4 V Voc, rank #21,456 of 21,677), while Merlin Solar Technologies Inc RFP-F024W120L delivers 120.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)