Gintung Energy ASEC-135G6M — CEC Solar Module Specifications

Manufacturer: Gintung Energy Registry: CEC Verified Engineering Specification

Gintung Energy ASEC-135G6M is a 135.0 W STC (120.6 W PTC) Multi-c-Si solar module ranking #21,456 of 21,677 CEC listings (below all-CEC median; higher than 1.0% of peers). It delivers 13.74% efficiency, 22.1 V Voc at 25 C, and 24.65 V cold Voc at -10 C (24 panels max per 600 V string).

STC Wattage
135.0 W
PTC Wattage
120.6 W
Voc @ 25C
22.1 V
Efficiency
13.74%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Gintung Energy ASEC-135G6M Compare Against Peer CEC Listings?

Engineering position of Gintung Energy ASEC-135G6M (135.0 W STC) vs. United Renewable Energy Co Ltd D6P135A1F across 1,407 CEC Multi-c-Si solar modules.

Built with 36 Multi-c-Si cells, Gintung Energy ASEC-135G6M pairs typical 89.3% PTC-to-STC thermal output (120.6 W real-world rating) with 22.1 V nominal Voc. An 8 kW residential build (8,100 W DC, 7,236 W PTC) saves ~$2,027/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer United Renewable Energy Co Ltd D6P135A1F offers a 135.0 W alternative.

Where Does Gintung Energy ASEC-135G6M Fall Across Listed CEC Models?

Plots Gintung Energy ASEC-135G6M at 135.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Gintung Energy ASEC-135G6M (135.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCGintung Energy ASE: 135.0 W

What Dataset Percentiles Define Gintung Energy ASEC-135G6M?

Benchmarks Gintung Energy ASEC-135G6M on STC wattage, thermal PTC/STC retention, and 13.74 aperture conversion efficiency against CEC peers.

Gintung Energy ASEC-135G6M Engineering BenchmarksPercentile comparison of Gintung Energy ASEC-135G6M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage135.0 WPTC/STC Retention89.3%Module Efficiency13.74%

What Do the Dataset Ranks Show for Gintung Energy ASEC-135G6M?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Gintung Energy ASEC-135G6M by Gintung Energy.

Rank #21,456 / 21,677

135.0 W STC · Higher Than 1.0%

135.0 W STC (-250.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,071

13.74% Aperture Efficiency

Power density 137.3 W/m2 (6.17 percentage points below 19.91% CEC median). PTC/STC ratio: 89.3% (rank #20,205).

NEC 690.7 Limit

24 Panels Max @ -10 C (600 V)

Cold Voc reaches 24.65 V at -10 C (591.6 V string) and 25.38 V at -20 C (23 max).

8 kW Reference Array

60 Panels = 8,100 W STC

Occupies 59.0 m2 (635 sq ft) producing 7,236 W PTC; NEC 690.8 OCPD floor is 12.89 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 22.1 * (1 + (-0.33/100) * (-10 - 25)) = 24.65 V | OCPD = 1.56 * 8.26 = 12.89 A

Inputs from CEC Modules.csv for Gintung Energy ASEC-135G6M: Voc=22.1 V, beta_Voc=-0.33%/C, Isc=8.26 A, STC=135.0 W, Area=0.983 m2.

Result: 24 panels max on 600 V (591.6 V); 60 panels for 8 kW (635 sq ft).

What Are the Published CEC Specifications for Gintung Energy ASEC-135G6M?

Laboratory test ratings recorded for Gintung Energy ASEC-135G6M (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Gintung Energy ASEC-135G6M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 135.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 120.6 W (89.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 22.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.26 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 17.68 V / 7.64 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.33 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.74% (0.983 m2) Array roof footprint density
Cell Count & Technology 36 cells (Multi-c-Si) Monofacial backsheet

How Many Gintung Energy ASEC-135G6M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (635 sq ft at 8 kW), and estimated Year-1 electric bill offset for Gintung Energy ASEC-135G6M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 45 6.08 kW 476 sq ft $1,522 $2,573
8 kW Class 60 8.1 kW 635 sq ft $2,027 $3,428
10 kW Class 75 10.12 kW 794 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?

Sibling wattage bins and frame colors grouped with Gintung Energy ASEC-135G6M under Gintung Energy to prevent duplicate spec pages.

Sibling CEC listings grouped into the Gintung Energy ASEC-135G6M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Gintung Energy ASEC-125G6M 125.0 W 111.5 W 21.58 V 17.19 V 12.72%
Gintung Energy ASEC-130G6M 130.0 W 116.0 W 21.66 V 17.54 V 13.23%
Gintung Energy ASEC-135G6M 135.0 W 120.6 W 22.1 V 17.68 V 13.74%
Gintung Energy ASEC-140G6M 140.0 W 125.2 W 22.25 V 17.75 V 14.24%

How Many Gintung Energy ASEC-135G6M Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Gintung Energy ASEC-135G6M (beta_Voc -0.33%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=22.1V and beta_Voc=-0.33%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 25.38 V 23 panels 583.7 V 39 panels
-10 C (14 F) 24.65 V 24 panels 591.6 V 40 panels
0 C (32 F) 23.92 V 25 panels 598.0 V 41 panels
25 C (77 F STC) 22.1 V 27 panels 596.7 V 45 panels

Which Cross-Brand Solar Modules Compare Closest to Gintung Energy ASEC-135G6M?

Closest cross-brand CEC competitors to Gintung Energy ASEC-135G6M matched near 135.0 W STC and 22.1 V Voc, led by United Renewable Energy Co Ltd D6P135A1F.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
United Renewable Energy Co Ltd D6P135A1F
United Renewable Energy Co Ltd
135.0 W Tie (0 W) 22.1 V 13.74% 89.3%
APOS Energy AP135
APOS Energy
135.0 W Tie (0 W) 22.21 V 13.2% 88.8%
Centrosolar America DP36 140
Centrosolar America
140.0 W +5.0 W 22.15 V 13.85% 88.4%
Solartech Energy ASC-6P-36-140
Solartech Energy
140.0 W +5.0 W 22.15 V 13.85% 88.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Gintung Energy ASEC-135G6M?

Evaluate Gintung Energy ASEC-135G6M (135.0 W STC, 22.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy ASEC-135G6M reaches 25.38 V per panel—exceeding 23 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 60 panels for an 8 kW build require 635 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 60 panels (635 sq ft).
  • 2026 tax credit baseline: cash residential installs of Gintung Energy ASEC-135G6M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Gintung Energy ASEC-135G6M 8 kW Residential Fit

Needs 60 modules (635 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 24 panels (-10 C) or 23 panels (-20 C), or compare United Renewable Energy Co Ltd D6P135A1F.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 120.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Gintung Energy ASEC-135G6M by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Gintung Energy ASEC-135G6M?

Multiplying Gintung Energy ASEC-135G6M's 8.26 A short-circuit current by 1.56 equals 12.89 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Gintung Energy ASEC-135G6M pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 24.65 V cold Voc at 14 F and handles 8.26 A Isc; string inverters cap Gintung Energy ASEC-135G6M at 24 panels on 600 V.

Is Gintung Energy ASEC-135G6M eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Gintung Energy ASEC-135G6M rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.