Centrosolar America DP36 140 — CEC Solar Module Specifications

Manufacturer: Centrosolar America Registry: CEC Verified Engineering Specification

Centrosolar America DP36 140 is a 140.0 W STC (123.7 W PTC) Multi-c-Si solar module ranking #21,440 of 21,677 CEC listings (below all-CEC median; higher than 1.0% of peers). It delivers 13.85% efficiency, 22.15 V Voc at 25 C, and 24.94 V cold Voc at -10 C (24 panels max per 600 V string).

STC Wattage
140.0 W
PTC Wattage
123.7 W
Voc @ 25C
22.15 V
Efficiency
13.85%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Centrosolar America DP36 140 Compare Against Peer CEC Listings?

Solar engineering breakdown for Centrosolar America DP36 140: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 1,407 Multi-c-Si listings from Centrosolar America and peers, Centrosolar America DP36 140 stands 138.8 W below the 278.8 W Multi-c-Si median and typical 88.4% PTC-to-STC thermal output (123.7 W real-world rating). Sizing 6 kW (43 panels) to 10 kW (72 panels) yields $1,507-$2,523/yr in baseline US bill offset. Lower 22.15 V string voltage fits 24 panels in series at 14 F and pairs easily with microinverters.

Where Does Centrosolar America DP36 140 Fall Across Listed CEC Models?

Distribution marker showing Centrosolar America DP36 140 (140.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Centrosolar America DP36 140 (140.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCentrosolar Americ: 140.0 W

What Dataset Percentiles Define Centrosolar America DP36 140?

Dataset percentiles tracking Centrosolar America DP36 140 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Centrosolar America DP36 140 Engineering BenchmarksPercentile comparison of Centrosolar America DP36 140 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage140.0 WPTC/STC Retention88.4%Module Efficiency13.85%

What Do the Dataset Ranks Show for Centrosolar America DP36 140?

Benchmark highlights for Centrosolar America DP36 140 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #21,440 / 21,677

140.0 W STC · Higher Than 1.0%

140.0 W STC (-245.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,010

13.85% Aperture Efficiency

Power density 138.5 W/m2 (6.06 percentage points below 19.91% CEC median). PTC/STC ratio: 88.4% (rank #21,190).

NEC 690.7 Limit

24 Panels Max @ -10 C (600 V)

Cold Voc reaches 24.94 V at -10 C (598.6 V string) and 25.74 V at -20 C (23 max).

8 kW Reference Array

58 Panels = 8,120 W STC

Occupies 58.6 m2 (631 sq ft) producing 7,175 W PTC; NEC 690.8 OCPD floor is 13.31 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 22.15 * (1 + (-0.36/100) * (-10 - 25)) = 24.94 V | OCPD = 1.56 * 8.53 = 13.31 A

Inputs from CEC Modules.csv for Centrosolar America DP36 140: Voc=22.15 V, beta_Voc=-0.36%/C, Isc=8.53 A, STC=140.0 W, Area=1.011 m2.

Result: 24 panels max on 600 V (598.6 V); 58 panels for 8 kW (631 sq ft).

What Are the Published CEC Specifications for Centrosolar America DP36 140?

Official CEC datasheet figures for Centrosolar America DP36 140 (Multi-c-Si) used in utility interconnection and permit reviews. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for Centrosolar America DP36 140.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 140.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 123.7 W (88.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 22.15 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.53 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 17.43 V / 8.03 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.36 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.85% (1.011 m2) Array roof footprint density
Cell Count & Technology 36 cells (Multi-c-Si) Monofacial backsheet

How Many Centrosolar America DP36 140 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Centrosolar America DP36 140 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 43 6.02 kW 468 sq ft $1,507 $2,548
8 kW Class 58 8.12 kW 631 sq ft $2,032 $3,437
10 kW Class 72 10.08 kW 784 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This Centrosolar America Series?

Consolidated Centrosolar America wattage variants sharing the Centrosolar America DP36 140 mechanical and cell layout. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sibling CEC listings grouped into the Centrosolar America DP36 140 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Centrosolar America DP36 130 130.0 W 114.7 W 21.69 V 16.41 V 12.86%
Centrosolar America DP36 135 135.0 W 119.2 W 21.9 V 16.92 V 13.36%
Centrosolar America DP36 140 140.0 W 123.7 W 22.15 V 17.43 V 13.85%
Centrosolar America DP36 145 145.0 W 128.3 W 22.37 V 17.9 V 14.35%

How Many Centrosolar America DP36 140 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Centrosolar America DP36 140 (24.94 V at 14 F).

Computed from Voc=22.15V and beta_Voc=-0.36%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 25.74 V 23 panels 592.0 V 38 panels
-10 C (14 F) 24.94 V 24 panels 598.6 V 40 panels
0 C (32 F) 24.14 V 24 panels 579.4 V 41 panels
25 C (77 F STC) 22.15 V 27 panels 598.0 V 45 panels

Which Cross-Brand Solar Modules Compare Closest to Centrosolar America DP36 140?

Competing CEC solar panels closest to Centrosolar America DP36 140 in nameplate wattage and Voc, starting with Solartech Energy ASC-6P-36-140.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Solartech Energy ASC-6P-36-140
Solartech Energy
140.0 W Tie (0 W) 22.15 V 13.85% 88.4%
US Solar USS-QCMI2-36-140
US Solar
140.0 W Tie (0 W) 22.15 V 13.85% 88.4%
Auxin Solar AXN6M409T140
Auxin Solar
140.0 W Tie (0 W) 22.03 V 14.29% 89.3%
APOS Energy AS140
APOS Energy
140.0 W Tie (0 W) 22.33 V 13.69% 89.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Centrosolar America DP36 140?

Evaluate Centrosolar America DP36 140 (140.0 W STC, 22.15 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Centrosolar America DP36 140 reaches 25.74 V per panel—exceeding 23 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 58 panels for an 8 kW build require 631 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 58 panels (631 sq ft).
  • 2026 tax credit baseline: cash residential installs of Centrosolar America DP36 140 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Centrosolar America DP36 140 8 kW Residential Fit

Needs 58 modules (631 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 24 panels (-10 C) or 23 panels (-20 C), or compare Solartech Energy ASC-6P-36-140.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 123.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Centrosolar America DP36 140 by Centrosolar America grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Centrosolar America DP36 140?

Multiplying Centrosolar America DP36 140's 8.53 A short-circuit current by 1.56 equals 13.31 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Centrosolar America DP36 140 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 24.94 V cold Voc at 14 F and handles 8.53 A Isc; string inverters cap Centrosolar America DP36 140 at 24 panels on 600 V.

Is Centrosolar America DP36 140 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Centrosolar America DP36 140 rely on utility bill offset (~$2,032/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.