US Solar USS-QCMI2-36-140 is a 140.0 W STC (123.7 W PTC) Multi-c-Si solar module ranking #21,440 of 21,677 CEC listings (below all-CEC median; higher than 1.0% of peers). It delivers 13.85% efficiency, 22.15 V Voc at 25 C, and 24.94 V cold Voc at -10 C (24 panels max per 600 V string).
- STC Wattage
- 140.0 W
- PTC Wattage
- 123.7 W
- Voc @ 25C
- 22.15 V
- Efficiency
- 13.85%
How Does US Solar USS-QCMI2-36-140 Compare Against Peer CEC Listings?
Solar engineering breakdown for US Solar USS-QCMI2-36-140: PTC thermal retention, roof footprint, and cold Voc string bounds. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
Across 1,407 Multi-c-Si listings from US Solar and peers, US Solar USS-QCMI2-36-140 stands 138.8 W below the 278.8 W Multi-c-Si median and typical 88.4% PTC-to-STC thermal output (123.7 W real-world rating). Sizing 6 kW (43 panels) to 10 kW (72 panels) yields $1,507-$2,523/yr in baseline US bill offset. Lower 22.15 V string voltage fits 24 panels in series at 14 F and pairs easily with microinverters.
Where Does US Solar USS-QCMI2-36-140 Fall Across Listed CEC Models?
Distribution marker showing US Solar USS-QCMI2-36-140 (140.0 W) relative to the 385.0 W all-CEC solar panel median. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
What Dataset Percentiles Define US Solar USS-QCMI2-36-140?
Dataset percentiles tracking US Solar USS-QCMI2-36-140 power output, thermal retention ratio, and aperture efficiency against 21,677 models. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
What Do the Dataset Ranks Show for US Solar USS-QCMI2-36-140?
Benchmark highlights for US Solar USS-QCMI2-36-140 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
140.0 W STC · Higher Than 1.0%
140.0 W STC (-245.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
13.85% Aperture Efficiency
Power density 138.5 W/m2 (6.06 percentage points below 19.91% CEC median). PTC/STC ratio: 88.4% (rank #21,190).
24 Panels Max @ -10 C (600 V)
Cold Voc reaches 24.94 V at -10 C (598.6 V string) and 25.74 V at -20 C (23 max).
58 Panels = 8,120 W STC
Occupies 58.6 m2 (631 sq ft) producing 7,175 W PTC; NEC 690.8 OCPD floor is 13.31 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 22.15 * (1 + (-0.36/100) * (-10 - 25)) = 24.94 V | OCPD = 1.56 * 8.53 = 13.31 A
Inputs from CEC Modules.csv for US Solar USS-QCMI2-36-140: Voc=22.15 V, beta_Voc=-0.36%/C, Isc=8.53 A, STC=140.0 W, Area=1.011 m2.
Result: 24 panels max on 600 V (598.6 V); 58 panels for 8 kW (631 sq ft).
What Are the Published CEC Specifications for US Solar USS-QCMI2-36-140?
Official CEC datasheet figures for US Solar USS-QCMI2-36-140 (Multi-c-Si) used in utility interconnection and permit reviews. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 140.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 123.7 W (88.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 22.15 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.53 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 17.43 V / 8.03 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.36 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.85% (1.011 m2) | Array roof footprint density |
| Cell Count & Technology | 36 cells (Multi-c-Si) | Monofacial backsheet |
How Many US Solar USS-QCMI2-36-140 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many US Solar USS-QCMI2-36-140 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 43 | 6.02 kW | 468 sq ft | $1,507 | $2,548 |
| 8 kW Class | 58 | 8.12 kW | 631 sq ft | $2,032 | $3,437 |
| 10 kW Class | 72 | 10.08 kW | 784 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This US Solar Series?
Consolidated US Solar wattage variants sharing the US Solar USS-QCMI2-36-140 mechanical and cell layout. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| US Solar USS-QCMI2-36-130 | 130.0 W | 114.7 W | 21.69 V | 16.41 V | 12.86% |
| US Solar USS-QCMI2-36-135 | 135.0 W | 119.2 W | 21.9 V | 16.92 V | 13.36% |
| US Solar USS-QCMI2-36-140 | 140.0 W | 123.7 W | 22.15 V | 17.43 V | 13.85% |
| US Solar USS-QCMI2-36-145 | 145.0 W | 128.3 W | 22.37 V | 17.9 V | 14.35% |
How Many US Solar USS-QCMI2-36-140 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on US Solar USS-QCMI2-36-140 (24.94 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 25.74 V | 23 panels | 592.0 V | 38 panels |
| -10 C (14 F) | 24.94 V | 24 panels | 598.6 V | 40 panels |
| 0 C (32 F) | 24.14 V | 24 panels | 579.4 V | 41 panels |
| 25 C (77 F STC) | 22.15 V | 27 panels | 598.0 V | 45 panels |
Which Cross-Brand Solar Modules Compare Closest to US Solar USS-QCMI2-36-140?
Competing CEC solar panels closest to US Solar USS-QCMI2-36-140 in nameplate wattage and Voc, starting with Centrosolar America DP36 140.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Centrosolar America DP36 140 Centrosolar America |
140.0 W | Tie (0 W) | 22.15 V | 13.85% | 88.4% |
| Solartech Energy ASC-6P-36-140 Solartech Energy |
140.0 W | Tie (0 W) | 22.15 V | 13.85% | 88.4% |
| Auxin Solar AXN6M409T140 Auxin Solar |
140.0 W | Tie (0 W) | 22.03 V | 14.29% | 89.3% |
| APOS Energy AS140 APOS Energy |
140.0 W | Tie (0 W) | 22.33 V | 13.69% | 89.6% |
What Are the Design Limits and Best-Fit Uses for US Solar USS-QCMI2-36-140?
Evaluate US Solar USS-QCMI2-36-140 (140.0 W STC, 22.15 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), US Solar USS-QCMI2-36-140 reaches 25.74 V per panel—exceeding 23 panels in series voids 600 V inverter warranties.
- Footprint constraint: 58 panels for an 8 kW build require 631 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 58 panels (631 sq ft).
- 2026 tax credit baseline: cash residential installs of US Solar USS-QCMI2-36-140 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
US Solar USS-QCMI2-36-140 8 kW Residential Fit
Needs 58 modules (631 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 24 panels (-10 C) or 23 panels (-20 C), or compare Centrosolar America DP36 140.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 123.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for US Solar USS-QCMI2-36-140 by US Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for US Solar USS-QCMI2-36-140?
Multiplying US Solar USS-QCMI2-36-140's 8.53 A short-circuit current by 1.56 equals 13.31 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can US Solar USS-QCMI2-36-140 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 24.94 V cold Voc at 14 F and handles 8.53 A Isc; string inverters cap US Solar USS-QCMI2-36-140 at 24 panels on 600 V.
Is US Solar USS-QCMI2-36-140 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of US Solar USS-QCMI2-36-140 rely on utility bill offset (~$2,032/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)