Manufacturer: US Solar Registry: CEC Verified Engineering Specification

US Solar USS-QCMI2-72-305 is a 305.0 W STC (270.6 W PTC) Multi-c-Si solar module ranking #16,131 of 21,677 CEC listings (below all-CEC median; higher than 23.9% of peers). It delivers 15.69% efficiency, 44.96 V Voc at 25 C, and 50.62 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
305.0 W
PTC Wattage
270.6 W
Voc @ 25C
44.96 V
Efficiency
15.69%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does US Solar USS-QCMI2-72-305 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for US Solar USS-QCMI2-72-305 (Multi-c-Si) residential solar systems.

Homeowners evaluating US Solar USS-QCMI2-72-305 need 20 panels for 6 kW or 27 panels (565 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (565 sq ft). Under NEC 690.7(A), beta_Voc (-0.36%/C) pushes open-circuit voltage to 50.62 V at 14 F and 52.24 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does US Solar USS-QCMI2-72-305 Fall Across Listed CEC Models?

Comparison of US Solar USS-QCMI2-72-305 (305.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where US Solar USS-QCMI2-72-305 (305.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCUS Solar USS-QCMI2: 305.0 W

What Dataset Percentiles Define US Solar USS-QCMI2-72-305?

Relative ranking of US Solar USS-QCMI2-72-305 across nameplate watts, 88.7% PTC thermal ratio, and module aperture efficiency. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

US Solar USS-QCMI2-72-305 Engineering BenchmarksPercentile comparison of US Solar USS-QCMI2-72-305 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage305.0 WPTC/STC Retention88.7%Module Efficiency15.69%

What Do the Dataset Ranks Show for US Solar USS-QCMI2-72-305?

Summary of US Solar USS-QCMI2-72-305 output rank, 8 kW array size (27 panels), efficiency rating, and 600 V string limit.

Rank #16,131 / 21,677

305.0 W STC · Higher Than 23.9%

305.0 W STC (-80.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,661

15.69% Aperture Efficiency

Power density 156.9 W/m2 (4.22 percentage points below 19.91% CEC median). PTC/STC ratio: 88.7% (rank #21,046).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.62 V at -10 C (556.8 V string) and 52.24 V at -20 C (11 max).

8 kW Reference Array

27 Panels = 8,235 W STC

Occupies 52.5 m2 (565 sq ft) producing 7,306 W PTC; NEC 690.8 OCPD floor is 13.51 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.96 * (1 + (-0.36/100) * (-10 - 25)) = 50.62 V | OCPD = 1.56 * 8.66 = 13.51 A

Inputs from CEC Modules.csv for US Solar USS-QCMI2-72-305: Voc=44.96 V, beta_Voc=-0.36%/C, Isc=8.66 A, STC=305.0 W, Area=1.944 m2.

Result: 11 panels max on 600 V (556.8 V); 27 panels for 8 kW (565 sq ft).

What Are the Published CEC Specifications for US Solar USS-QCMI2-72-305?

Complete CEC test sheet for US Solar USS-QCMI2-72-305 including Isc (8.66 A), Voc (44.96 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for US Solar USS-QCMI2-72-305.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 305.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 270.6 W (88.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.96 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.66 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.85 V / 8.27 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.36 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.69% (1.944 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many US Solar USS-QCMI2-72-305 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using US Solar USS-QCMI2-72-305.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.1 kW 419 sq ft $1,527 $2,582
8 kW Class 27 8.23 kW 565 sq ft $2,060 $3,483
10 kW Class 33 10.06 kW 691 sq ft $2,518 $4,258

Which Sibling Wattage & Trim Variants Belong to This US Solar Series?

Related US Solar power steps and black/silver trims consolidated into this US Solar USS-QCMI2-72-305 series guide. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Sibling CEC listings grouped into the US Solar USS-QCMI2-72-305 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
US Solar USS-QCMI2-72-300 300.0 W 266.0 W 44.82 V 36.52 V 15.43%
US Solar USS-QCMI2-72-305 305.0 W 270.6 W 44.96 V 36.85 V 15.69%

How Many US Solar USS-QCMI2-72-305 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for US Solar USS-QCMI2-72-305 (44.96 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=44.96V and beta_Voc=-0.36%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.24 V 11 panels 574.6 V 19 panels
-10 C (14 F) 50.62 V 11 panels 556.8 V 19 panels
0 C (32 F) 49.01 V 12 panels 588.1 V 20 panels
25 C (77 F STC) 44.96 V 13 panels 584.5 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to US Solar USS-QCMI2-72-305?

Four comparable CEC modules such as Auxin Solar AXN6P612T305G (305.0 W) for side-by-side solar quote checks. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN6P612T305G
Auxin Solar
305.0 W Tie (0 W) 45.0 V 15.63% 90.3%
Auxin Solar AXN6M612T310
Auxin Solar
310.0 W +5.0 W 45.0 V 15.89% 89.4%
CSI Solar Co Ltd CS6X-310P
CSI Solar Co Ltd
310.0 W +5.0 W 44.9 V 16.31% 91.4%
AXITEC AC-310P/156-72S
AXITEC
310.0 W +5.0 W 45.05 V 16.01% 89.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for US Solar USS-QCMI2-72-305?

Evaluate US Solar USS-QCMI2-72-305 (305.0 W STC, 44.96 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), US Solar USS-QCMI2-72-305 reaches 52.24 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 27 panels for an 8 kW build require 565 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (565 sq ft).
  • 2026 tax credit baseline: cash residential installs of US Solar USS-QCMI2-72-305 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

US Solar USS-QCMI2-72-305 8 kW Residential Fit

Needs 27 modules (565 sq ft) with a 15 A string OCPD, offsetting ~$2,060/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN6P612T305G.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 270.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for US Solar USS-QCMI2-72-305 by US Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is US Solar USS-QCMI2-72-305 PTC wattage (270.6 W) lower than STC (305.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 270.6 W PTC (88.7% retention) across US Solar USS-QCMI2-72-305's 1.944 m2 aperture.

Who should skip US Solar USS-QCMI2-72-305 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 27 US Solar USS-QCMI2-72-305 panels (565 sq ft) leave unusable roof gaps vs. Auxin Solar AXN6P612T305G.

What is the 1,000 V commercial string limit for US Solar USS-QCMI2-72-305?

On 1,000 V commercial inverters at -10 C (50.62 V cold Voc), US Solar USS-QCMI2-72-305 fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting US Solar USS-QCMI2-72-305.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.